<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>46</CFRTITLE>
    <CFRTITLETEXT>Shipping</CFRTITLETEXT>
    <VOL>7</VOL>
    <DATE>1998-10-01</DATE>
    <ORIGINALDATE>1998-10-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Breathing supply hoses.</TITLE>
    <GRANULENUM>197.312</GRANULENUM>
    <HEADING>Section 197.312</HEADING>
    <ANCESTORS>
      <PARENT HEADING="" SEQ="5"/>
      <PARENT HEADING="" SEQ="4"/>
      <PARENT HEADING="SUBCHAPTER V" SEQ="3">MARINE OCCUPATIONAL SAFETY AND HEALTH STANDARDS</PARENT>
      <PARENT HEADING="PART 197" SEQ="2">GENERAL PROVISIONS</PARENT>
      <PARENT HEADING="Subpart B" SEQ="1">Commercial Diving Operations</PARENT>
      <PARENT HEADING="" SEQ="0">Equipment</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 197.312</SECTNO>
    <SUBJECT>Breathing supply hoses.</SUBJECT>
    <P>(a) Each breathing supply hose must—</P>
    <P>(1) Have a maximum working pressure that is equal to or exceeds—</P>
    <P>(i) The maximum working pressure of the section of the breathing supply system in which used; and</P>
    <P>(ii) The pressure equivalent of the maximum depth of the dive relative to the supply source plus 100 psig;</P>
    <P>(2) Have a bursting pressure of four times its maximum working pressure;</P>
    <P>(3) Have connectors that—</P>
    <P>(i) Are made of corrosion-resistant material;</P>
    <P>(ii) Are resistant to accidental disengagement; and</P>
    <P>(iii) Have a maximum working pressure that is at least equal to the maximum working pressure of the hose to which they are attached; and</P>
    <P>(4) Resist kinking by—</P>
    <P>(i) Being made of kink-resistant materials; or</P>
    <P>(ii) Having exterior support.</P>
    <P>(b) Each umbilical must—</P>
    <P>(1) Meet the requirements of paragraph (a) of this section; and</P>
    <P>(2) Be marked from the diver or open bell end in 10-foot intervals to 100 feet and in 50-foot intervals thereafter.</P>
  </SECTION>