    <P>(a) Each surface-supplied helmet or mask must have—</P>
    <P>(1) A nonreturn valve at the attachment point between helmet or mask and umbilical that closes readily and positively;</P>
    <P>(2) An exhaust valve; and</P>
    <P>(3) A two-way voice communication system between the diver and the dive location or bell.</P>
    <P>(b) Each surface-supplied air helmet or mask must—</P>
    <P>(1) Ventilate at least 4.5 ACFM at any depth at which it is operated; or</P>
    <P>(2) Be able to maintain the diver's inspired carbon dioxide partial pressure below 0.02 ATA when the diver is producing carbon dioxide at the rate of 1.6 standard liters per minute.</P>