<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>46</CFRTITLE>
    <CFRTITLETEXT>Shipping</CFRTITLETEXT>
    <VOL>7</VOL>
    <DATE>1998-10-01</DATE>
    <ORIGINALDATE>1998-10-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Breathing supply hoses.</TITLE>
    <GRANULENUM>197.456</GRANULENUM>
    <HEADING>Section 197.456</HEADING>
    <ANCESTORS>
      <PARENT HEADING="" SEQ="5"/>
      <PARENT HEADING="" SEQ="4"/>
      <PARENT HEADING="SUBCHAPTER V" SEQ="3">MARINE OCCUPATIONAL SAFETY AND HEALTH STANDARDS</PARENT>
      <PARENT HEADING="PART 197" SEQ="2">GENERAL PROVISIONS</PARENT>
      <PARENT HEADING="Subpart B" SEQ="1">Commercial Diving Operations</PARENT>
      <PARENT HEADING="" SEQ="0">Periodic Tests and Inspections of Diving Equipment</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 197.456</SECTNO>
    <SUBJECT>Breathing supply hoses.</SUBJECT>
    <P>(a) The diving supervisor shall insure that—</P>
    <P>(1) Each breathing supply hose is pressure tested prior to being placed into initial service and every 24 months thereafter to 1.5 times its maximum working pressure;</P>
    <P>(2) Each breathing supply hose assembly, prior to being placed into initial service and after any repair, modification, or alteration, is tensile tested by—</P>
    <P>(i) Subjecting each hose-to-fitting connection to a 200 pound axial load; and</P>
    <P>(ii) Passing a visual examination for evidence of separation, slippage, or other damage to the assembly;</P>
    <P>(3) Each breathing supply hose is periodically checked for—</P>
    <P>(i) Damage which is likely to affect pressure integrity; and</P>
    <P>(ii) Contamination which is likely to affect the purity of the breathing mixture delivered to the diver; and</P>
    <P>(4) The open ends of each breathing supply hose are taped, capped, or plugged when not in use.</P>

    <P>(b) To meet the requirements of paragraph (a)(3) of this section, each breathing supply hose must be—<PRTPAGE P="403"/>
    </P>
    <P>(1) Carefully inspected before being shipped to the dive location;</P>
    <P>(2) Visually checked during daily operation; and</P>
    <P>(3) Checked for noxious or offensive odor before each diving operation.</P>