    <SECTNO>§ 197.458</SECTNO>
    <SUBJECT>Gages and timekeeping devices.</SUBJECT>
    <P>The diving supervisor shall insure that—</P>
    <P>(a) Each depth gage and timekeeping device is tested or calibrated against a master reference gage or time- keeping device every 6 months;</P>
    <P>(b) A depth gage is tested when a discrepancy exists in a depth gage reading greater than 2 percent of full scale between any two gages of similar range and calibration;</P>
    <P>(c) A timekeeping device is tested when a discrepancy exists in a timekeeping device reading greater than one-quarter of a minute in a 4-hour period between any two timekeeping devices; and</P>
    <P>(d) Each depth gage and timekeeping device is inspected before diving operations are begun.</P>