    <TITLE>Circuit protective devices.</TITLE>
    <GRANULENUM>23.1357</GRANULENUM>
    <HEADING>Section 23.1357</HEADING>
    <ANCESTORS>
      <PARENT HEADING="" SEQ="6"/>
      <PARENT HEADING="" SEQ="5"/>
      <PARENT HEADING="SUBCHAPTER C" SEQ="4">AIRCRAFT</PARENT>
      <PARENT HEADING="PART 23" SEQ="3">AIRWORTHINESS STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES</PARENT>
      <PARENT HEADING="" SEQ="2">Sfar No. 41</PARENT>
      <PARENT HEADING="Subpart F" SEQ="1">Equipment</PARENT>
      <PARENT HEADING="" SEQ="0">Electrical Systems and Equipment</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 23.1357</SECTNO>
    <SUBJECT>Circuit protective devices.</SUBJECT>
    <P>(a) Protective devices, such as fuses or circuit breakers, must be installed in all electrical circuits other than—</P>
    <P>(1) Main circuits of starter motors used during starting only; and</P>
    <P>(2) Circuits in which no hazard is presented by their omission.</P>
    <P>(b) A protective device for a circuit essential to flight safety may not be used to protect any other circuit.</P>
    <P>(c) Each resettable circuit protective device (“trip free” device in which the tripping mechanism cannot be overridden by the operating control) must be designed so that—</P>
    <P>(1) A manual operation is required to restore service after tripping; and</P>
    <P>(2) If an overload or circuit fault exists, the device will open the circuit regardless of the position of the operating control.</P>
    <P>(d) If the ability to reset a circuit breaker or replace a fuse is essential to safety in flight, that circuit breaker or fuse must be so located and identified that it can be readily reset or replaced in flight.</P>
    <P>(e) For fuses identified as replaceable in flight—</P>
    <P>(1) There must be one spare of each rating or 50 percent spare fuses of each rating, whichever is greater; and</P>
    <P>(2) The spare fuse(s) must be readily accessible to any required pilot.</P>
    <CITA>[Doc. No. 4080, 29 FR 17955, Dec. 18, 1964; 30 FR 258, Jan. 9, 1965, as amended by Amdt. 23-20, 42 FR 36969, July 18, 1977]; Amdt. 23-43, 58 FR 18976, Apr. 9, 1993</CITA>