    <P>Each relay, the functioning of which affects the safety of train operations, shall be tested at least once every four years except:</P>
    <P>(a) Alternating current centrifugal type relay shall be tested at least once every 12 months;</P>
    <P>(b) Alternating current vane type relay and direct current polar type relay shall be tested at least once every 2 years; and</P>
    <P>(c) Relay with soft iron magnetic structure shall be tested at least once every 2 years.</P>
    <CITA>[49 FR 3384, Jan. 26, 1984]</CITA>