<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>21</VOL>
    <DATE>2000-07-01</DATE>
    <ORIGINALDATE>2000-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>EFFLUENT GUIDELINES AND STANDARDS</TITLE>
    <GRANULENUM>N</GRANULENUM>
    <HEADING>SUBCHAPTER N</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="1">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="0">ENVIRONMENTAL PROTECTION AGENCY-(Continued)</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SUBCHAP TYPE="N">
    <PRTPAGE P="5"/>
    <HD SOURCE="HED">SUBCHAPTER N—EFFLUENT GUIDELINES AND STANDARDS</HD>
    <PART>
      <RESERVED>PART 400[RESERVED]</RESERVED>
    </PART>
    <PART>
      <EAR>Pt. 401</EAR>
      <HD SOURCE="HED">PART 401—GENERAL PROVISIONS</HD>
      <CONTENTS>
        <SECHD>Sec.</SECHD>
        <SECTNO>401.10</SECTNO>
        <SUBJECT>Scope and purpose.</SUBJECT>
        <SECTNO>401.11</SECTNO>
        <SUBJECT>General definitions.</SUBJECT>
        <SECTNO>401.12</SECTNO>
        <SUBJECT>Law authorizing establishment of effluent limitations guidelines for existing sources, standards of performance for new sources and pretreatment standards of new and existing sources.</SUBJECT>
        <SECTNO>401.13</SECTNO>
        <SUBJECT>Test procedures for measurement.</SUBJECT>
        <SECTNO>401.14</SECTNO>
        <SUBJECT>Cooling water intake structures.</SUBJECT>
        <SECTNO>401.15</SECTNO>
        <SUBJECT>Toxic pollutants.</SUBJECT>
        <SECTNO>401.16</SECTNO>
        <SUBJECT>Conventional pollutants</SUBJECT>
        <SECTNO>401.17</SECTNO>
        <SUBJECT>pH Effluent limitations under continuous monitoring.</SUBJECT>
      </CONTENTS>
      <AUTH>
        <HD SOURCE="HED">Authority:</HD>
        <P>Secs. 301, 304 (b) and (c), 306 (b) and (c), 307 (b) and (c) and 316(b) of the Federal Water Pollution Control Act, as amended (the “Act”), 33 U.S.C. 1251, 1311, 1314 (b) and (c), 1316 (b) and (c), 1317 (b) and (c) and 1326(c); 86 Stat. 816 et seq.; Pub. L. 92-500.</P>
      </AUTH>
      <SOURCE>
        <HD SOURCE="HED">Source:</HD>
        <P>39 FR 4532, Feb. 1, 1974, unless otherwise noted.</P>
      </SOURCE>
      <SECTION>
        <SECTNO>§ 401.10</SECTNO>
        <SUBJECT>Scope and purpose.</SUBJECT>
        <P>Regulations promulgated or proposed under parts 402 through 699 of this subchapter prescribe effluent limitations guidelines for existing sources, standards of performance for new sources and pretreatment standards for new and existing sources pursuant to sections 301, 304 (b) and (c), 306 (b) and (c), 307 (b) and (c) and 316(b) of the Federal Water Pollution Control Act, as amended (the “Act”), 33 U.S.C. 1251, 1311, 1314 (b) and (c), 1316 (b) and (c), 1317 (b) and (c) and 1326(b); 86 Stat. 816; Pub. L. 92-500. Point sources of discharges of pollutants are required to comply with these regulations, where applicable, and permits issued by States or the Environmental Protection Agency (EPA) under the National Pollutant Discharge Elimination System (NPDES) established pursuant to section 402 of the Act must be conditioned upon compliance with applicable requirements of sections 301 and 306 (as well as certain other requirements). This part 401 sets forth the legal authority and general definitions which will apply to all regulations issued concerning specific classes and categories of point sources under parts 402 through 699 of this subchapter which follow. In certain instances the regulations applicable to a particular point source category or subcategory will contain more specialized definitions. Except as provided in § 401.17, in the case of any conflict between regulations issued under this part 401 and regulations issued under parts 402 through 499 of this subchapter, the latter more specific regulations shall apply.</P>
        <SECAUTH>(Secs. 301, 304, 306 and 501 of the Clean Water Act (the Federal Water Pollution Control Act Amendments of 1972, 33 U.S.C. 1251 et. seq., as amended by the Clean Water Act of 1977, Pub. L. 95-217))</SECAUTH>
        <CITA>[39 FR 4532, Feb. 1, 1974, as amended at 47 FR 24537, June 4, 1982]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 401.11</SECTNO>
        <SUBJECT>General definitions.</SUBJECT>
        <P>For the purposes of parts 402 through 699 of this subchapter:</P>
        <P>(a) The term <E T="03">Act</E> means the Federal Water Pollution Control Act, as amended, 33 U.S.C. 1251 et seq., 86 Stat. 816, Pub. L. 92-500.</P>
        <P>(b) The term <E T="03">Administrator</E> means the Administrator of the United States Environmental Protection Agency.</P>
        <P>(c) The term <E T="03">Environmental Protection Agency</E> means the United States Environmental Protection Agency.</P>
        <P>(d) The term <E T="03">point source</E> means any discernible, confined and discrete conveyance, including but not limited to any pipe, ditch, channel, tunnel, conduit, well, discrete fissure, container, rolling stock, concentrated animal feeding operation, or vessel or other floating craft, from which pollutants are or may be discharged.</P>
        <P>(e) The term <E T="03">new source</E> means any building, structure, facility or installation from which there is or may be the discharge of pollutants, the construction of which is commenced after the publication of proposed regulations prescribing a standard of performance under section 306 of the Act which will be applicable to such source if such standard is thereafter promulgated in accordance with section 306 of the Act.</P>
        <P>(f) The term <E T="03">pollutant</E> means dredged spoil, solid waste, incinerator residue, <PRTPAGE P="6"/>sewage, garbage, sewage sludge, munitions, chemical wastes, biological materials, radioactive materials, heat, wrecked or discarded equipment, rock, sand, cellar dirt and industrial, municipal and agricultural waste discharged into water. It does not mean (1) sewage from vessels or (2) water, gas or other material which is injected into a well to facilitate production of oil or gas, or water derived in association with oil or gas production and disposed of in a well, if the well, used either to facilitate production or for disposal purposes, is approved by authority of the State in which the well is located, and if such State determines that such injection or disposal will not result in degradation of ground or surface water resources.</P>
        <P>(g) The term <E T="03">pollution</E> means the man-made or man induced alteration of the chemical, physical, biological and radiological integrity of water.</P>
        <P>(h) The term <E T="03">discharge of pollutant(s)</E> means: (1) The addition of any pollutant to navigable waters from any point source and (2) any addition of any pollutant to the waters of the contiguous zone or the ocean from any point source, other than from a vessel or other floating craft. The term “discharge” includes either the discharge of a single pollutant or the discharge of multiple pollutants.</P>
        <P>(i) The term <E T="03">effluent limitation</E> means any restriction established by the Administrator on quantities, rates, and concentrations of chemical, physical, biological and other constituents which are discharged from point sources, other than new sources, into navigable waters, the waters of the contiguous zone or the ocean.</P>
        <P>(j) The term <E T="03">effluent limitations guidelines</E> means any effluent limitations guidelines issued by the Administrator pursuant to section 304(b) of the Act.</P>
        <P>(k) The term <E T="03">standard of performance</E> means any restriction established by the Administrator pursuant to section 306 of the Act on quantities, rates, and concentrations of chemical, physical, biological, and other constituents which are or may be discharged from new sources into navigable waters, the waters of the contiguous zone or the ocean.</P>
        <P>(l) The term <E T="03">navigable waters</E> includes: All navigable waters of the United States; tributaries of navigable waters of the United States; interstate waters; intrastate lakes, rivers, and streams which are utilized by interstate travelers for recreational or other purposes; intrastate lakes, rivers, and streams from which fish or shellfish are taken and sold in interstate commerce; and intrastate lakes, rivers, and streams which are utilized for industrial purposes by industries in interstate commerce. Navigable waters do not include prior converted cropland. Notwithstanding the determination of an area's status as prior converted cropland by any other federal agency, for the purposes of the Clean Water Act, the final authority regarding Clean Water Act jurisdiction remains with EPA.</P>
        <P>(m) The terms <E T="03">state water pollution control agency, interstate agency, State, municipality, person, territorial seas, contiguous zone, biological monitoring, schedule of compliance,</E> and <E T="03">industrial user</E> shall be defined in accordance with section 502 of the Act unless the context otherwise requires.</P>
        <P>(n) The term <E T="03">noncontract cooling water</E> means water used for cooling which does not come into direct contact with any raw material, intermediate product, waste product or finished product.</P>
        <P>(o) The term <E T="03">noncontact cooling water pollutants</E> means pollutants present in noncontact cooling waters.</P>
        <P>(p) The term <E T="03">blowdown</E> means the minimum discharge of recirculating water for the purpose of discharging materials contained in the water, the further buildup of which would cause concentration in amounts exceeding limits established by best engineering practice.</P>
        <P>(q) The term <E T="03">process waste water</E> means any water which, during manufacturing or processing, comes into direct contact with or results from the production or use of any raw material, intermediate product, finished product, by-product, or waste product.</P>
        <P>(r) The term <E T="03">process waste water pollutants</E> means pollutants present in process waste water.</P>

        <P>(s) The following abbreviations shall have the following meanings:<PRTPAGE P="7"/>
        </P>
        <P>(1) <E T="03">BOD5</E> means five-day biochemical oxygen demand;</P>
        <P>(2) <E T="03">COD</E> means chemical oxygen demand;</P>
        <P>(3) <E T="03">TOC</E> means total organic carbon;</P>
        <P>(4) <E T="03">TDS</E> means total dissolved solids;</P>
        <P>(5) <E T="03">TSS</E> means total suspended non-filterable solids;</P>
        <P>(6) <E T="03">kw</E> means kilowatt(s);</P>
        <P>(7) <E T="03">kwh</E> means kilowatt hour(s);</P>
        <P>(8) <E T="03">Mw</E> means megawatt(s);</P>
        <P>(9) <E T="03">Mwh</E> means megawatt hour(s);</P>
        <P>(10) <E T="03">hp</E> means horsepower;</P>
        <P>(11) <E T="03">mm</E> means millimeter(s);</P>
        <P>(12) <E T="03">cm</E> means centimeter;</P>
        <P>(13) <E T="03">m</E> means meter(s);</P>
        <P>(14) <E T="03">in.</E> means inch;</P>
        <P>(15) <E T="03">ft</E> means foot (feet);</P>
        <P>(16) <E T="03">l</E> means liter(s);</P>
        <P>(17) <E T="03">cu m</E> means cubic meter(s);</P>
        <P>(18) <E T="03">k cu m</E> means 1000 cubic meter(s);</P>
        <P>(19) <E T="03">gal</E> means gallon(s);</P>
        <P>(20) <E T="03">cu ft</E> means cubic foot (feet);</P>
        <P>(21) <E T="03">mg</E> means milligram(s);</P>
        <P>(22) <E T="03">g</E> means gram(s);</P>
        <P>(23) <E T="03">kg</E> means kilogram(s);</P>
        <P>(24) <E T="03">kkg</E> means 1000 kilogram(s);</P>
        <P>(25) <E T="03">lb</E> means pound(s);</P>
        <P>(26) <E T="03">sq m</E> means square meter(s);</P>
        <P>(27) <E T="03">ha</E> means hectare(s);</P>
        <P>(28) <E T="03">sq ft</E> means square foot (feet); and</P>
        <P>(29) <E T="03">ac</E> means acre(s).</P>
        <CITA>[39 FR 4532, Feb. 1, 1974, as amended at 58 FR 45038, Aug. 25, 1994]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 401.12</SECTNO>
        <SUBJECT>Law authorizing establishment of effluent limitations guidelines for existing sources, standards of performance for new sources and pretreatment standards of new and existing sources.</SUBJECT>
        <P>(a) Section 301(a) of the Act provides that “except as in compliance with this section and sections 302, 306, 307, 318, 402 and 404 of this Act, the discharge of any pollutant by any person shall be unlawful.”</P>
        <P>(b) Section 301(b) of the Act requires the achievement by not later than July 1, 1977, of effluent limitations for point sources, other than publicly owned treatment works, which require the application of the best practicable control technology currently available as determined by the Administrator pursuant to section 304(b)(1) of the Act. Section 301(b) also requires the achievement by not later than July 1, 1983, of effluent limitations for point sources, other than publicly owned treatment works, which require the application of the best available technology economically achievable which will result in reasonable further progress toward the national goal of eliminating the discharge of all pollutants, as determined in accordance with regulations issued by the Administrator pursuant to section 304(b)(2) of the Act.</P>
        <P>(c) Section 304(b) of the Act requires the Administrator to publish regulations providing guidelines for effluent limitations setting forth the degree of effluent reduction attainable through the application of the best practicable control technology currently available and the degree of effluent reduction attainable through the application of the best control measures and practices achievable including treatment techniques, process and procedure innovations, operating methods and other alternatives.</P>
        <P>(d) Section 304(c) of the Act requires the Administrator, after consultation with appropriate Federal and State agencies and other interested persons to issue information on the process, procedures, or operating methods which result in the elimination or reduction of the discharge of pollutants to implement standards of performance under section 306 of the Act.</P>
        <P>(e) Section 306(b)(1)(B) of the Act requires the Administrator, after a category of sources is included in a list published pursuant to section 306(b)(1)(A) of the Act, to propose regulations establishing Federal standards of performances for new sources within such category. Standards of performance are to provide for the control of the discharge of pollutants which reflect the greatest degree of effluent reduction which the Administrator determines to be achievable through application of the best available demonstrated control technology, processes, operating methods, or other alternatives, including, where practicable, a standard permitting no discharge of pollutants.</P>

        <P>(f) Section 307(b) provides that the Administrator shall establish pretreatment standards which shall prevent the discharge of any pollutant into publicly owned treatment works which pollutant interferes with, passes <PRTPAGE P="8"/>through untreated, or otherwise is incompatible with such works.</P>
        <P>(g) Section 307(c) of the Act provides that the Administrator shall promulgate pretreatment standards for sources which would be “new sources” under section 306 (if they were to discharge pollutants directly to navigable waters) at the same time standards of performance for the equivalent category of new sources are promulgated.</P>
        <P>(h) Section 316(b) of the Act provides that any standard established pursuant to section 301 or section 306 of the Act and applicable to a point source shall require that the location, design, construction, and capacity of cooling water intake structures reflect the best technology available for minimizing adverse environmental impact.</P>
        <P>(i) Section 402(a)(1) of the Act provides that the Administrator may issue permits for the discharge of any pollutant upon condition that such discharge will meet all applicable requirements under sections 301, 302, 306, 307, 308 and 403 of this Act. In addition, section 402(b)(1)(A) of the Act requires that permits issued by States under the National Pollutant Discharge Elimination System (NPDES) established by the Act must apply, and insure compliance with any applicable requirements of sections 301, 302, 306, 307 and 403 of the Act.</P>
      </SECTION>
      <SECTION>
        <SECTNO>§ 401.13</SECTNO>
        <SUBJECT>Test procedures for measurement.</SUBJECT>
        <P>The test procedures for measurement which are prescribed at part 136 of this chapter shall apply to expressions of pollutant amounts, characteristics or properties in effluent limitations guidelines and standards of performance and pretreatment standards as set forth at parts 402 through 699 of this subchapter, unless otherwise specifically noted or defined in said parts.</P>
      </SECTION>
      <SECTION>
        <SECTNO>§ 401.14</SECTNO>
        <SUBJECT>Cooling water intake structures.</SUBJECT>
        <P>The location, design, construction and capacity of cooling water intake structures of any point source for which a standard is established pursuant to section 301 or 306 of the Act shall reflect the best technology available for minimizing adverse environmental impact, in accordance with the provisions of part 402 of this chapter.</P>
        <SECAUTH>(Sec. 501(a) of the Federal Water Pollution Control Act, as amended; 33 U.S.C. 1326(b) and 1261(a))</SECAUTH>
        <CITA>[41 FR 17389, Apr. 26, 1976]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 401.15</SECTNO>
        <SUBJECT>Toxic pollutants.</SUBJECT>

        <P>The following comprise the list of toxic pollutants designated pursuant to section 307(a)(1) of the Act:
        </P>
        <EXTRACT>
          <FP SOURCE="FP-2">1. Acenaphthene</FP>
          <FP SOURCE="FP-2">2. Acrolein</FP>
          <FP SOURCE="FP-2">3. Acrylonitrile</FP>
          <FP>4. Aldrin/Dieldrin <SU>1</SU>
            <FTREF/>
          </FP>
          <FTNT>
            <P>
              <SU>1</SU> Effluent standard promulgated (40 CFR part 129). </P>
          </FTNT>
          <FP>5. Antimony and compounds <SU>2</SU>
            <FTREF/>
          </FP>
          <FTNT>
            <P>
              <SU>2</SU> The term <E T="03">compounds</E> shall include organic and inorganic compounds.</P>
          </FTNT>
          <FP SOURCE="FP-2">6. Arsenic and compounds</FP>
          <FP SOURCE="FP-2">7. Asbestos</FP>
          <FP SOURCE="FP-2">8. Benzene</FP>
          <FP SOURCE="FP-2">9. Benzidine <SU>1</SU>
          </FP>
          <FP SOURCE="FP-2">10. Beryllium and compounds</FP>
          <FP SOURCE="FP-2">11. Cadmium and compounds</FP>
          <FP SOURCE="FP-2">12. Carbon tetrachloride</FP>
          <FP SOURCE="FP-2">13. Chlordane (technical mixture and metabolites)</FP>
          <FP SOURCE="FP-2">14. Chlorinated benzenes (other than di-chlorobenzenes)</FP>
          <FP SOURCE="FP-2">15. Chlorinated ethanes (including 1,2-di-chloroethane, 1,1,1-trichloroethane, and hexachloroethane)</FP>
          <FP SOURCE="FP-2">16. Chloroalkyl ethers (chloroethyl and mixed ethers)</FP>
          <FP SOURCE="FP-2">17. Chlorinated naphthalene</FP>
          <FP SOURCE="FP-2">18. Chlorinated phenols (other than those listed elsewhere; includes trichlorophenols and chlorinated cresols)</FP>
          <FP SOURCE="FP-2">19. Chloroform</FP>
          <FP SOURCE="FP-2">20. 2-chlorophenol</FP>
          <FP SOURCE="FP-2">21. Chromium and compounds</FP>
          <FP SOURCE="FP-2">22. Copper and compounds</FP>
          <FP SOURCE="FP-2">23. Cyanides</FP>
          <FP SOURCE="FP-2">24. DDT and metabolites <SU>1</SU>
          </FP>
          <FP SOURCE="FP-2">25. Dichlorobenzenes (1,2-, 1,3-, and 1,4-di-chlorobenzenes)</FP>
          <FP SOURCE="FP-2">26. Dichlorobenzidine</FP>
          <FP SOURCE="FP-2">27. Dichloroethylenes (1,1-, and 1,2-dichloroethylene)</FP>
          <FP SOURCE="FP-2">28. 2,4-dichlorophenol</FP>
          <FP SOURCE="FP-2">29. Dichloropropane and dichloropropene</FP>
          <FP SOURCE="FP-2">30. 2,4-dimethylphenol</FP>
          <FP SOURCE="FP-2">31. Dinitrotoluene</FP>
          <FP SOURCE="FP-2">32. Diphenylhydrazine</FP>
          <FP SOURCE="FP-2">33. Endosulfan and metabolites</FP>
          <FP SOURCE="FP-2">34. Endrin and metabolites <SU>1</SU>
          </FP>
          <FP SOURCE="FP-2">35. Ethylbenzene</FP>
          <FP SOURCE="FP-2">36. Fluoranthene</FP>

          <FP SOURCE="FP-2">37. Haloethers (other than those listed elsewhere; includes chlorophenylphenyl ethers, bromophenylphenyl ether, <PRTPAGE P="9"/>bis(dichloroisopropyl) ether, bis-(chloroethoxy) methane and polychlorinated diphenyl ethers)</FP>
          <FP SOURCE="FP-2">38. Halomethanes (other than those listed elsewhere; includes methylene chloride, methylchloride, methylbromide, bromoform, dichlorobromomethane</FP>
          <FP SOURCE="FP-2">39. Heptachlor and metabolites</FP>
          <FP SOURCE="FP-2">40. Hexachlorobutadiene</FP>
          <FP SOURCE="FP-2">41. Hexachlorocyclohexane</FP>
          <FP SOURCE="FP-2">42. Hexachlorocyclopentadiene</FP>
          <FP SOURCE="FP-2">43. Isophorone</FP>
          <FP SOURCE="FP-2">44. Lead and compounds</FP>
          <FP SOURCE="FP-2">45. Mercury and compounds</FP>
          <FP SOURCE="FP-2">46. Naphthalene</FP>
          <FP SOURCE="FP-2">47. Nickel and compounds</FP>
          <FP SOURCE="FP-2">48. Nitrobenzene</FP>
          <FP SOURCE="FP-2">49. Nitrophenols (including 2,4-dinitrophenol, dinitrocresol)</FP>
          <FP SOURCE="FP-2">50. Nitrosamines</FP>
          <FP SOURCE="FP-2">51. Pentachlorophenol</FP>
          <FP SOURCE="FP-2">52. Phenol</FP>
          <FP SOURCE="FP-2">53. Phthalate esters</FP>
          <FP SOURCE="FP-2">54. Polychlorinated biphenyls (PCBs) <SU>1</SU>
          </FP>
          <FP SOURCE="FP-2">55. Polynuclear aromatic hydrocarbons (including benzanthracenes, benzopyrenes, benzofluoranthene, chrysenes, dibenz-anthracenes, and indenopyrenes)</FP>
          <FP SOURCE="FP-2">56. Selenium and compounds</FP>
          <FP SOURCE="FP-2">57. Silver and compounds</FP>
          <FP SOURCE="FP-2">58. 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD)</FP>
          <FP SOURCE="FP-2">59. Tetrachloroethylene</FP>
          <FP SOURCE="FP-2">60. Thallium and compounds</FP>
          <FP SOURCE="FP-2">61. Toluene</FP>
          <FP SOURCE="FP-2">62. Toxaphene <SU>1</SU>
          </FP>
          <FP SOURCE="FP-2">63. Trichloroethylene</FP>
          <FP SOURCE="FP-2">64. Vinyl chloride</FP>
          <FP SOURCE="FP-2">65. Zinc and compounds</FP>
        </EXTRACT>
        <CITA>[44 FR 44502, July 30, 1979, as amended at 46 FR 2266, Jan. 8, 1981; 46 FR 10724, Feb. 4, 1981]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 401.16</SECTNO>
        <SUBJECT>Conventional pollutants.</SUBJECT>

        <P>The following comprise the list of conventional pollutants designated pursuant to section 304(a)(4) of the Act:
        </P>
        <EXTRACT>
          <FP SOURCE="FP-2">1. Biochemical oxygen demand (BOD)</FP>
          <FP SOURCE="FP-2">2. Total suspended solids (nonfilterable) (TSS)</FP>
          <FP SOURCE="FP-2">3. pH</FP>
          <FP SOURCE="FP-2">4. Fecal coliform</FP>
          <FP SOURCE="FP-2">5. Oil and grease</FP>
        </EXTRACT>
        <CITA>[44 FR 44503, July 30, 1979; 44 FR 52685, Sept. 10, 1979]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 401.17</SECTNO>
        <SUBJECT>pH Effluent limitations under continuous monitoring.</SUBJECT>
        <P>(a) Where a permittee continuously measures the pH of wastewater pursuant to a requirement or option in a National Pollutant Discharge Elimination System (NPDES) permit issued pursuant to section 402 of the Act, the permittee shall maintain the pH of such wastewater within the range set forth in the applicable effluent limitations guidelines, except excursions from the range are permitted subject to the following limitations:</P>
        <P>(1) The total time during which the pH values are outside the required range of pH values shall not exceed 7 hours and 26 minutes in any calendar month; and</P>
        <P>(2) No individual excursion from the range of pH values shall exceed 60 minutes.</P>
        <P>(b) The Director, as defined in § 122.3 of this chapter, may adjust the requirements set forth in paragraph (a) of this section with respect to the length of individual excursions from the range of pH values, if a different period of time is appropriate based upon the treatment system, plant configuration or other technical factors.</P>
        <P>(c) For purposes of this section, an <E T="03">excursion</E> is an unintentional and temporary incident in which the pH value of discharge wastewater exceeds the range set forth in the applicable effluent limitations guidelines.</P>
        <SECAUTH>(Secs. 301, 304, 306 and 501 of the Clean Water Act (the Federal Water Pollution Control Act Amendments of 1972, 33 U.S.C. 1251 et. seq., as amended by the Clean Water Act of 1977, Pub. L. 95-217))</SECAUTH>
        <CITA>[47 FR 24537, June 4, 1982]</CITA>
      </SECTION>
    </PART>
    <PART>
      <RESERVED>PART 402[RESERVED]</RESERVED>
    </PART>
    <PART>
      <EAR>Pt. 403</EAR>
      <HD SOURCE="HED">PART 403—GENERAL PRETREAT- MENT REGULATIONS FOR EXISTING AND NEW SOURCES OF POLLUTION</HD>
      <CONTENTS>
        <SECHD>Sec.</SECHD>
        <SECTNO>403.1</SECTNO>
        <SUBJECT>Purpose and applicability.</SUBJECT>
        <SECTNO>403.2</SECTNO>
        <SUBJECT>Objectives of general pretreatment regulations.</SUBJECT>
        <SECTNO>403.3</SECTNO>
        <SUBJECT>Definitions.</SUBJECT>
        <SECTNO>403.4</SECTNO>
        <SUBJECT>State or local law.</SUBJECT>
        <SECTNO>403.5</SECTNO>
        <SUBJECT>National pretreatment standards: Prohibited discharges.</SUBJECT>
        <SECTNO>403.6</SECTNO>
        <SUBJECT>National pretreatment standards: Categorical standards.</SUBJECT>
        <SECTNO>403.7</SECTNO>
        <SUBJECT>Removal credits.</SUBJECT>
        <SECTNO>403.8</SECTNO>
        <SUBJECT>Pretreatment Program Requirements: Development and Implementation by POTW.</SUBJECT>
        <SECTNO>403.9</SECTNO>

        <SUBJECT>POTW pretreatment programs and/or authorization to revise pretreatment standards: Submission for approval.<PRTPAGE P="10"/>
        </SUBJECT>
        <SECTNO>403.10</SECTNO>
        <SUBJECT>Development and submission of NPDES State pretreatment programs.</SUBJECT>
        <SECTNO>403.11</SECTNO>
        <SUBJECT>Approval procedures for POTW pretreatment programs and POTW granting of removal credits.</SUBJECT>
        <SECTNO>403.12</SECTNO>
        <SUBJECT>Reporting requirements for POTW's and industrial users.</SUBJECT>
        <SECTNO>403.13</SECTNO>
        <SUBJECT>Variances from categorical pretreatment standards for fundamentally different factors.</SUBJECT>
        <SECTNO>403.14</SECTNO>
        <SUBJECT>Confidentiality.</SUBJECT>
        <SECTNO>403.15</SECTNO>
        <SUBJECT>Net/Gross calculation.</SUBJECT>
        <SECTNO>403.16</SECTNO>
        <SUBJECT>Upset provision.</SUBJECT>
        <SECTNO>403.17</SECTNO>
        <SUBJECT>Bypass.</SUBJECT>
        <SECTNO>403.18</SECTNO>
        <SUBJECT>Modification of POTW pretreatment programs.</SUBJECT>
        <APP>Appendix A to Part 403—Program Guidance Memorandum</APP>
        <APP>Appendixes B-C to Part 403[Reserved]</APP>
        <APP>Appendix D to Part 403—Selected Industrial Subcategories Considered Dilute for Purposes of the Combined Wastestream Formula</APP>
        <APP>Appendix E to Part 403—Sampling Procedures</APP>
        <APP>Appendix F[Reserved]</APP>
        <APP>Appendix G to Part 403—Pollutants Eligible for a Removal Credit</APP>
      </CONTENTS>
      <AUTH>
        <HD SOURCE="HED">Authority:</HD>
        <P>33 U.S.C. 1251 <E T="03">et seq</E>.</P>
      </AUTH>
      <SOURCE>
        <HD SOURCE="HED">Source:</HD>
        <P>46 FR 9439, Jan. 28, 1981, unless otherwise noted.</P>
      </SOURCE>
      <SECTION>
        <SECTNO>§ 403.1</SECTNO>
        <SUBJECT>Purpose and applicability.</SUBJECT>
        <P>(a) This part implements sections 204(b)(1)(C), 208(b)(2) (C)(iii), 301(b)(1)(A)(ii), 301(b)(2) (A)(ii), 301(h)(5) and 301(i)(2), 304 (e) and (g), 307, 308, 309, 402(b), 405, and 501(a) of the Federal Water Pollution Control Act as amended by the Clean Water Act of 1977 (Pub. L. 95-217) or “The Act”. It establishes responsibilities of Federal, State, and local government, industry and the public to implement National Pretreatment Standards to control pollutants which pass through or interfere with treatment processes in Publicly Owned Treatment Works (POTWs) or which may contaminate sewage sludge.</P>
        <P>(b) This regulation applies:</P>
        <P>(1) To pollutants from non-domestic sources covered by Pretreatment Standards which are indirectly discharged into or transported by truck or rail or otherwise introduced into POTWs as defined below in § 403.3;</P>
        <P>(2) To POTWs which receive wastewater from sources subject to National Pretreatment Standards;</P>
        <P>(3) To States which have or are applying for National Pollutant Discharge Elimination System (NPDES) programs approved in accordance with section 402 of the Act; and</P>
        <P>(4) To any new or existing source subject to Pretreatment Standards. National Pretreatment Standards do not apply to sources which Discharge to a sewer which is not connected to a POTW Treatment Plant.</P>
        <CITA>[46 FR 9439, Jan. 28, 1981, as amended at 48 FR 2776, Jan. 21, 1983; 60 FR 33932, June 29, 1995]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 403.2</SECTNO>
        <SUBJECT>Objectives of general pretreatment regulations.</SUBJECT>
        <P>By establishing the responsibilities of government and industry to implement National Pretreatment Standards this regulation fulfills three objectives:</P>
        <P>(a) To prevent the introduction of pollutants into POTWs which will interfere with the operation of a POTW, including interference with its use or disposal of municipal sludge;</P>
        <P>(b) To prevent the introduction of pollutants into POTWs which will pass through the treatment works or otherwise be incompatible with such works; and</P>
        <P>(c) To improve opportunities to recycle and reclaim municipal and industrial wastewaters and sludges.</P>
      </SECTION>
      <SECTION>
        <SECTNO>§ 403.3</SECTNO>
        <SUBJECT>Definitions.</SUBJECT>
        <P>For the purposes of this part:</P>
        <P>(a) Except as discussed below, the general definitions, abbreviations, and methods of analysis set forth in 40 CFR part 401 shall apply to this regulation.</P>
        <P>(b) The term <E T="03">Act</E> means Federal Water Pollution Control Act, also known as the Clean Water Act, as amended, 33 U.S.C. 1251, et seq.</P>
        <P>(c) The term <E T="03">Approval Authority</E> means the Director in an NPDES State with an approved State pretreatment program and the appropriate Regional Administrator in a non-NPDES State or NPDES State without an approved State pretreatment program.</P>
        <P>(d) The term <E T="03">Approved POTW Pretreatment Program</E> or <E T="03">Program</E> or <E T="03">POTW Pretreatment Program</E> means a program administered by a POTW that meets the criteria established in this regulation (§§ 403.8 and 403.9) and which has been approved by a Regional Administrator or State Director in accordance with § 403.11 of this regulation.<PRTPAGE P="11"/>
        </P>
        <P>(e) The term <E T="03">Director</E> means the chief administrative officer of a State or Interstate water pollution control agency with an NPDES permit program approved pursuant to section 402(b) of the Act and an approved State pretreatment program.</P>
        <P>(f) The term <E T="03">Water Management Division Director</E> means one of the Directors of the Water Management Divisions within the Regional offices of the Environmental Protection Agency or this person's delegated representative.</P>
        <P>(g) The term <E T="03">Indirect Discharge</E> or <E T="03">Discharge</E> means the introduction of pollutants into a POTW from any non-domestic source regulated under section 307(b), (c) or (d) of the Act.</P>
        <P>(h) The term <E T="03">Industrial User</E> or <E T="03">User</E> means a source of Indirect Discharge.</P>
        <P>(i) The term <E T="03">Interference</E> means a Discharge which, alone or in conjunction with a discharge or discharges from other sources, both:</P>
        <P>(1) Inhibits or disrupts the POTW, its treatment processes or operations, or its sludge processes, use or disposal; and</P>
        <P>(2) Therefore is a cause of a violation of any requirement of the POTW's NPDES permit (including an increase in the magnitude or duration of a violation) or of the prevention of sewage sludge use or disposal in compliance with the following statutory provisions and regulations or permits issued thereunder (or more stringent State or local regulations): Section 405 of the Clean Water Act, the Solid Waste Disposal Act (SWDA) (including title II, more commonly referred to as the Resource Conservation and Recovery Act (RCRA), and including State regulations contained in any State sludge management plan prepared pursuant to subtitle D of the SWDA), the Clean Air Act, the Toxic Substances Control Act, and the Marine Protection, Research and Sanctuaries Act.</P>
        <P>(j) The term <E T="03">National Pretreatment Standard, Pretreatment Standard,</E> or <E T="03">Standard</E> means any regulation containing pollutant discharge limits promulgated by the EPA in accordance with section 307 (b) and (c) of the Act, which applies to Industrial Users. This term includes prohibitive discharge limits established pursuant to § 403.5.</P>
        <P>(k)(1) The term <E T="03">New Source</E> means any building, structure, facility or installation from which there is or may be a Discharge of pollutants, the construction of which commenced after the publication of proposed Pretreatment Standards under section 307(c) of the Act which will be applicable to such source if such Standards are thereafter promulgated in accordance with that section, <E T="03">provided that:</E>
        </P>
        <P>(i) The building, structure, facility or installation is constructed at a site at which no other source is located; or</P>
        <P>(ii) The building, structure, facility or installation totally replaces the process or production equipment that causes the discharge of pollutants at an existing source; or</P>
        <P>(iii) The production or wastewater generating processes of the building, structure, facility or installation are substantially independent of an existing source at the same site. In determining whether these are substantially independent, factors such as the extent to which the new facility is integrated with the existing plant, and the extent to which the new facility is engaged in the same general type of activity as the existing source should be considered.</P>
        <P>(2) Construction on a site at which an existing source is located results in a modification rather than a new source if the construction does not create a new building, structure, facility or installation meeting the criteria of paragraphs (k)(1)(ii), or (k)(1)(iii) of this section but otherwise alters, replaces, or adds to existing process or production equipment.</P>
        <P>(3) Construction of a new source as defined under this paragraph has commenced if the owner or operator has:</P>
        <P>(i) Begun, or caused to begin as part of a continuous onsite construction program:</P>
        <P>(A) Any placement, assembly, or installation of facilities or equipment; or</P>

        <P>(B) Significant site preparation work including clearing, excavation, or removal of existing buildings, structures, or facilities which is necessary for the placement, assembly, or installation of new source facilities or equipment; or<PRTPAGE P="12"/>
        </P>
        <P>(ii) Entered into a binding contractual obligation for the purchase of facilities or equipment which are intended to be used in its operation within a reasonable time. Options to purchase or contracts which can be terminated or modified without substantial loss, and contracts for feasibility, engineering, and design studies do not constitute a contractual obligation under this paragraph.</P>
        <P>(l) The terms <E T="03">NPDES Permit</E> or <E T="03">Permit</E> means a permit issued to a POTW pursuant to section 402 of the Act.</P>
        <P>(m) The term <E T="03">NPDES State</E> means a State (as defined in 40 CFR 122.2) or Interstate water pollution control agency with an NPDES permit program approved pursuant to section 402(b) of the Act.</P>
        <P>(n) The term <E T="03">Pass Through</E> means a Discharge which exits the POTW into waters of the United States in quantities or concentrations which, alone or in conjunction with a discharge or discharges from other sources, is a cause of a violation of any requirement of the POTW's NPDES permit (including an increase in the magnitude or duration of a violation).</P>
        <P>(o) The term <E T="03">Publicly Owned Treatment Works</E> or <E T="03">POTW</E> means a treatment works as defined by section 212 of the Act, which is owned by a State or municipality (as defined by section 502(4) of the Act). This definition includes any devices and systems used in the storage, treatment, recycling and reclamation of municipal sewage or industrial wastes of a liquid nature. It also includes sewers, pipes and other conveyances only if they convey wastewater to a POTW Treatment Plant. The term also means the municipality as defined in section 502(4) of the Act, which has jurisdiction over the Indirect Discharges to and the discharges from such a treatment works.</P>
        <P>(p) The term <E T="03">POTW Treatment Plant</E> means that portion of the POTW which is designed to provide treatment (including recycling and reclamation) of municipal sewage and industrial waste.</P>
        <P>(q) The term <E T="03">Pretreatment</E> means the reduction of the amount of pollutants, the elimination of pollutants, or the alteration of the nature of pollutant properties in wastewater prior to or in lieu of discharging or otherwise introducing such pollutants into a POTW. The reduction or alteration may be obtained by physical, chemical or biological processes, process changes or by other means, except as prohibited by § 403.6(d). Appropriate pretreatment technology includes control equipment, such as equalization tanks or facilities, for protection against surges or slug loadings that might interfere with or otherwise be incompatible with the POTW. However, where wastewater from a regulated process is mixed in an equalization facility with unregulated wastewater or with wastewater from another regulated process, the effluent from the equalization facility must meet an adjusted pretreatment limit calculated in accordance with § 403.6(e).</P>
        <P>(r) The term <E T="03">Pretreatment requirements</E> means any substantive or procedural requirement related to Pretreatment, other than a National Pretreatment Standard, imposed on an Industrial User.</P>
        <P>(s) The term <E T="03">Regional Administrator</E> means the appropriate EPA Regional Administrator.</P>
        <P>(t) <E T="03">Significant Industrial User.</E> (1) Except as provided in paragraph (t)(2) of this section, the term Significant Industrial User means:</P>
        <P>(i) All industrial users subject to Categorical Pretreatment Standards under 40 CFR 403.6 and 40 CFR chapter I, subchapter N; and</P>
        <P>(ii) Any other industrial user that: discharges an average of 25,000 gallons per day or more of process wastewater to the POTW (excluding sanitary, noncontact cooling and boiler blowdown wastewater); contributes a process wastestream which makes up 5 percent or more of the average dry weather hydraulic or organic capacity of the POTW treatment plant; or is designated as such by the Control Authority as defined in 40 CFR 403.12(a) on the basis that the industrial user has a reasonable potential for adversely affecting the POTW's operation or for violating any pretreatment standard or requirement (in accordance with 40 CFR 403.8(f)(6)).</P>

        <P>(2) Upon a finding that an industrial user meeting the criteria in paragraph (t)(1)(ii) of this section has no reasonable potential for adversely affecting the POTW's operation or for violating <PRTPAGE P="13"/>any pretreatment standard or requirement, the Control Authority (as defined in 40 CFR 403.12(a)) may at any time, on its own initiative or in response to a petition received from an industrial user or POTW, and in accordance with 40 CFR 403.8(f)(6), determine that such industrial user is not a significant industrial user.</P>
        <P>(u) The term <E T="03">Submission</E> means:</P>
        <P>(1) A request by a POTW for approval of a Pretreatment Program to the EPA or a Director;</P>
        <P>(2) A request by a POTW to the EPA or a Director for authority to revise the discharge limits in categorical Pretreatment Standards to reflect POTW pollutant removals; or</P>
        <P>(3) A request to the EPA by an NPDES State for approval of its State pretreatment program.</P>
        <CITA>[46 FR 9439, Jan. 28, 1981, as amended at 49 FR 5132, Feb. 10, 1984; 49 FR 28059, July 10, 1984; 51 FR 20430, June 4, 1986; 51 FR 23760, July 1, 1986; 52 FR 1600, Jan. 14, 1987; 53 FR 40610, Oct. 17, 1988; 55 FR 30129, July 24, 1990]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 403.4</SECTNO>
        <SUBJECT>State or local law.</SUBJECT>
        <P>Nothing in this regulation is intended to affect any Pretreatment Requirements, including any standards or prohibitions, established by State or local law as long as the State or local requirements are not less stringent than any set forth in National Pretreatment Standards, or any other requirements or prohibitions established under the Act or this regulation. States with an NPDES permit program approved in accordance with section 402 (b) and (c) of the Act, or States requesting NPDES programs, are responsible for developing a State pretreatment program in accordance with § 403.10 of this regulation.</P>
      </SECTION>
      <SECTION>
        <SECTNO>§ 403.5</SECTNO>
        <SUBJECT>National pretreatment standards: Prohibited discharges.</SUBJECT>
        <P>(a)(1) <E T="03">General prohibitions.</E> A User may not introduce into a POTW any pollutant(s) which cause Pass Through or Interference. These general prohibitions and the specific prohibitions in paragraph (b) of this section apply to each User introducing pollutants into a POTW whether or not the User is subject to other National Pretreatment Standards or any national, State, or local Pretreatment Requirements.</P>
        <P>(2) <E T="03">Affirmative Defenses.</E> A User shall have an affirmative defense in any action brought against it alleging a violation of the general prohibitions established in paragraph (a)(1) of this section and the specific prohibitions in paragraphs (b)(3), (b)(4), (b)(5), (b)(6), and (b)(7) of this section where the User can demonstrate that:</P>
        <P>(i) It did not know or have reason to know that its Discharge, alone or in conjunction with a discharge or discharges from other sources, would cause Pass Through or Interference; and</P>
        <P>(ii)(A) A local limit designed to prevent Pass Through and/or Interference, as the case may be, was developed in accordance with paragraph (c) of this section for each pollutant in the User's Discharge that caused Pass Through or Interference, and the User was in compliance with each such local limit directly prior to and during the Pass Through or Interference; or</P>
        <P>(B) If a local limit designed to prevent Pass Through and/or Interference, as the case may be, has not been developed in accordance with paragraph (c) of this section for the pollutant(s) that caused the Pass Through or Interference, the User's Discharge directly prior to and during the Pass Through or Interference did not change substantially in nature or constituents from the User's prior discharge activity when the POTW was regularly in compliance with the POTW's NPDES permit requirements and, in the case of Interference, applicable requirements for sewage sludge use or disposal.</P>
        <P>(b) <E T="03">Specific prohibitions.</E> In addition, the following pollutants shall not be introduced into a POTW:</P>
        <P>(1) Pollutants which create a fire or explosion hazard in the POTW, including, but not limited to, wastestreams with a closed cup flashpoint of less than 140 degrees Farenheit or 60 degrees Centigrade using the test methods specified in 40 CFR 261.21.</P>
        <P>(2) Pollutants which will cause corrosive structural damage to the POTW, but in no case Discharges with pH lower than 5.0, unless the works is specifically designed to accommodate such Discharges;</P>

        <P>(3) Solid or viscous pollutants in amounts which will cause obstruction <PRTPAGE P="14"/>to the flow in the POTW resulting in Interference;</P>
        <P>(4) Any pollutant, including oxygen demanding pollutants (BOD, etc.) released in a Discharge at a flow rate and/or pollutant concentration which will cause Interference with the POTW.</P>
        <P>(5) Heat in amounts which will inhibit biological activity in the POTW resulting in Interference, but in no case heat in such quantities that the temperature at the POTW Treatment Plant exceeds 40 °C (104 °F) unless the Approval Authority, upon request of the POTW, approves alternate temperature limits.</P>
        <P>(6) Petroleum oil, nonbiodegradable cutting oil, or products of mineral oil origin in amounts that will cause interference or pass through;</P>
        <P>(7) Pollutants which result in the presence of toxic gases, vapors, or fumes within the POTW in a quantity that may cause acute worker health and safety problems;</P>
        <P>(8) Any trucked or hauled pollutants, except at discharge points designated by the POTW.</P>
        <P>(c) <E T="03">When specific limits must be developed by POTW.</E> (1) Each POTW developing a POTW Pretreatment Program pursuant to § 403.8 shall develop and enforce specific limits to implement the prohibitions listed in paragraphs (a)(1) and (b) of this section. Each POTW with an approved pretreatment program shall continue to develop these limits as necessary and effectively enforce such limits.</P>
        <P>(2) All other POTW's shall, in cases where pollutants contributed by User(s) result in Interference or Pass-Through, and such violation is likely to recur, develop and enforce specific effluent limits for Industrial User(s), and all other users, as appropriate, which, together with appropriate changes in the POTW Treatment Plant's facilities or operation, are necessary to ensure renewed and continued compliance with the POTW's NPDES permit or sludge use or disposal practices.</P>
        <P>(3) Specific effluent limits shall not be developed and enforced without individual notice to persons or groups who have requested such notice and an opportunity to respond.</P>
        <P>(d) <E T="03">Local limits.</E> Where specific prohibitions or limits on pollutants or pollutant parameters are developed by a POTW in accordance with paragraph (c) above, such limits shall be deemed Pretreatment Standards for the purposes of section 307(d) of the Act.</P>
        <P>(e) EPA enforcement actions under section 309(f) of the Clean Water Act.</P>
        <P>If, within 30 days after notice of an Interference or Pass Through violation has been sent by EPA to the POTW, and to persons or groups who have requested such notice, the POTW fails to commence appropriate enforcement action to correct the violation, EPA may take appropriate enforcement action under the authority provided in section 309(f) of the Clean Water Act.</P>
        <CITA>[46 FR 9439, Jan. 28, 1981, as amended at 51 FR 20430, June 4, 1986; 52 FR 1600, Jan. 14, 1987; 55 FR 30129, July 24, 1990; 60 FR 33932, June 29, 1995]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 403.6</SECTNO>
        <SUBJECT>National pretreatment standards: Categorical standards.</SUBJECT>
        <P>National pretreatment standards specifying quantities or concentrations of pollutants or pollutant properties which may be discharged to a POTW by existing or new industrial users in specific industrial subcategories will be established as separate regulations under the appropriate subpart of 40 CFR chapter I, subchapter N. These standards, unless specifically noted otherwise, shall be in addition to all applicable pretreatment standards and requirements set forth in this part.</P>
        <P>(a) <E T="03">Category Determination Request</E>—(1) <E T="03">Application Deadline.</E> Within 60 days after the effective date of a Pretreatment Standard for a subcategory under which an Industrial User may be included, the Industrial User or POTW may request that the Water Management Division Director or Director, as appropriate, provide written certification on whether the Industrial User falls within that particular subcategory. If an existing Industrial User adds or changes a process or operation which may be included in a subcategory, the existing Industrial User must request this certification prior to commencing discharge from the added or changed processes or operation. A New Source must request this <PRTPAGE P="15"/>certification prior to commencing discharge. Where a request for certification is submitted by a POTW, the POTW shall notify any affected Industrial User of such submission. The Industrial User may provide written comments on the POTW submission to the Water Management Division Director or Director, as appropriate, within 30 days of notification.</P>
        <P>(2) <E T="03">Contents of Application</E>. Each request shall contain a statement:</P>
        <P>(i) Describing which subcategories might be applicable; and</P>

        <P>(ii) Citing evidence and reasons why a particular subcategory is applicable and why others are not applicable. Any person signing the application statement submitted pursuant to this section shall make the following certification:
        </P>
        <EXTRACT>
          <P>I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.</P>
        </EXTRACT>
        
        <P>(3) <E T="03">Deficient requests.</E> The Water Management Division Director or Director will only act on written requests for determinations that contain all of the information required. Persons who have made incomplete submissions will be notified by the Water Management Division Director or Director that their requests are deficient and, unless the time period is extended, will be given 30 days to correct the deficiency. If the deficiency is not corrected within 30 days or within an extended period allowed by the Water Management Division Director or the Director, the request for a determination shall be denied.</P>
        <P>(4) <E T="03">Final decision.</E> (i) When the Water Management Division Director or Director receives a submittal he or she will, after determining that it contains all of the information required by paragraph (2) of this section, consider the submission, any additional evidence that may have been requested, and any other available information relevant to the request. The Water Management Division Director or Director will then make a written determination of the applicable subcategory and state the reasons for the determination.</P>
        <P>(ii) Where the request is submitted to the Director, the Director shall forward the determination described in this paragraph to the Water Management Division Director who may make a final determination. The Water Management Division Director may waive receipt of these determinations. If the Water Management Division Director does not modify the Director's decision within 60 days after receipt thereof, or if the Water Management Division Director waives receipt of the determination, the Director's decision is final.</P>
        <P>(iii) Where the request is submitted by the Industrial User or POTW to the Water Management Division Director or where the Water Management Division Director elects to modify the Director's decision, the Water Management Division Director's decision will be final.</P>
        <P>(iv) The Water Management Division Director or Director, as appropriate, shall send a copy of the determination to the affected Industrial User and the POTW. Where the final determination is made by the Water Management Division Director, he or she shall send a copy of the determination to the Director.</P>
        <P>(5) <E T="03">Requests for hearing and/or legal decision.</E> Within 30 days following the date of receipt of notice of the final determination as provided for by paragraph (a)(4)(iv) of this section, the Requester may submit a petition to reconsider or contest the decision to the Regional Administrator who shall act on such petition expeditiously and state the reasons for his or her determination in writing.</P>
        <P>(b) <E T="03">Deadline for Compliance with Categorical Standards.</E> Compliance by existing sources with categorical Pretreatment Standards shall be within 3 years of the date the Standard is effective unless a shorter compliance time is specified in the appropriate subpart of 40 CFR chapter I, subchapter N. Direct dischargers with NPDES permits modified or reissued to provide a <PRTPAGE P="16"/>variance pursuant to section 301(i)(2) of the Act shall be required to meet compliance dates set in any applicable categorical Pretreatment Standard. Existing sources which become Industrial Users subsequent to promulgation of an applicable categorical Pretreatment Standard shall be considered existing Industrial Users except where such sources meet the definition of a New Source as defined in § 403.3(k). New Sources shall install and have in operating condition, and shall “start-up” all pollution control equipment required to meet applicable Pretreatment Standards before beginning to Discharge. Within the shortest feasible time (not to exceed 90 days), New Sources must meet all applicable Pretreatment Standards.</P>
        <P>(c)(1) <E T="03">Concentration and mass limits.</E> Pollutant discharge limits in categorical Pretreatment Standards will be expressed either as concentration or mass limits. Wherever possible, where concentration limits are specified in standards, equivalent mass limits will be provided so that local, State or Federal authorities responsible for enforcement may use either concentration or mass limits. Limits in categorical Pretreatment Standards shall apply to the effluent of the process regulated by the Standard, or as otherwise specified by the standard.</P>
        <P>(2) When the limits in a categorical Pretreatment Standard are expressed only in terms of mass of pollutant per unit of production, the Control Authority may convert the limits to equivalent limitations expressed either as mass of pollutant discharged per day of effluent concentration for purposes of calculating effluent limitations applicable to individual Industrial Users.</P>
        <P>(3) A Control Authority calculating equivalent mass-per-day limitations under paragraph (c)(2) of this section shall calculate such limitations by multiplying the limits in the Standard by the Industrial User's average rate of production. This average rate of production shall be based not upon the designed production capacity but rather upon a reasonable measure of the Industrial User's actual long-term daily production, such as the average daily production during a representative year. For new sources, actual production shall be estimated using projected production.</P>
        <P>(4) A Control Authority calculating equivalent concentration limitations under paragraph (c)(2) of this section shall calculate such limitations by dividing the mass limitations derived under paragraph (c)(3) of this section by the average daily flow rate of the Industrial User's regulated process wastewater. This average daily flow rate shall be based upon a reasonable measure of the Industrial User's actual long-term average flow rate, such as the average daily flow rate during the representative year.</P>
        <P>(5) Equivalent limitations calculated in accordance with paragraphs (c)(3) and (c)(4) of this section shall be deemed Pretreatment Standards for the purposes of section 307(d) of the Act and this part. Industrial Users will be required to comply with the equivalent limitations in lieu of the promulgated categorical standards from which the equivalent limitations were derived.</P>
        <P>(6) Many categorical pretreatment standards specify one limit for calculating maximum daily discharge limitations and a second limit for calculating maximum monthly average, or 4-day average, limitations. Where such Standards are being applied, the same production of flow figure shall be used in calculating both types of equivalent limitations.</P>
        <P>(7) Any Industrial User operating under a control mechanism incorporating equivalent mass or concentration limits calculated from a production based standard shall notify the Control Authority within two (2) business days after the User has a reasonable basis to know that the production level will significantly change within the next calendar month. Any User not notifying the Control Authority of such anticipated change will be required to meet the mass or concentration limits in its control mechanism that were based on the original estimate of the long term average production rate.</P>
        <P>(d) <E T="03">Dilution Prohibited as Substitute for Treatment.</E> Except where expressly authorized to do so by an applicable Pretreatment Standard or Requirement, no Industrial User shall ever increase the use of process water, or in <PRTPAGE P="17"/>any other way attempt to dilute a discharge as a partial or complete substitute for adequate treatment to achieve compliance with a Pretreatment Standard or Requirement. The Control Authority (as defined in § 403.12(a)) may impose mass limitations on Industrial Users which are using dilution to meet applicable Pretreatment Standards or Requirements, or in other cases where the imposition of mass limitations is appropriate.</P>
        <P>(e) <E T="03">Combined wastestream formula.</E> Where process effluent is mixed prior to treatment with wastewaters other than those generated by the regulated process, fixed alternative discharge limits may be derived by the Control Authority, as defined in § 403.12(a), or by the Industrial User with the written concurrence of the Control Authority. These alternative limits shall be applied to the mixed effluent. When deriving alternative categorical limits, the Control Authority or Industrial User shall calculate both an alternative daily maximum value using the daily maximum value(s) specified in the appropriate categorical Pretreatment Standard(s) and an alternative consecutive sampling day average value using the monthly average value(s) specified in the appropriate categorical Pretreatment Standard(s). The Industrial User shall comply with the alternative daily maximum and monthly average limits fixed by the Control Authority until the Control Authority modifies the limits or approves an Industrial User modification request. Modification is authorized whenever there is a material or significant change in the values used in the calculation to fix alternative limits for the regulated pollutant. An Industrial User must immediately report any such material or significant change to the Control Authority. Where appropriate new alternative categorical limits shall be calculated within 30 days.</P>
        <P>(1) <E T="03">Alternative limit calculation.</E> For purposes of these formulas, the “average daily flow” means a reasonable measure of the average daily flow for a 30-day period. For new sources, flows shall be estimated using projected values. The alternative limit for a specified pollutant will be derived by the use of either of the following formulas:</P>
        <P>(i) <E T="03">Alternative concentration limit.</E>
        </P>
        <MATH DEEP="061" SPAN="1">
          <MID>EC15NO91.012</MID>
        </MATH>
        <EXTRACT>
          <FP>where</FP>
          
          <FP SOURCE="FP-1">C<E T="22">T</E>=the alternative concentration limit for the combined wastestream.</FP>
          <FP SOURCE="FP-1">C<E T="22">i</E>=the categorical Pretreatment Standard concentration limit for a pollutant in the regulated stream i.</FP>
          <FP SOURCE="FP-1">F<E T="22">i</E>=the average daily flow (at least a 30-day average) of stream i to the extent that it is regulated for such pollutant.</FP>
          <FP SOURCE="FP-1">F<E T="52">D</E>=the average daily flow (at least a 30-day average) from: (a) Boiler blowdown streams, non-contact cooling streams, stormwater streams, and demineralizer backwash streams; provided, however, that where such streams contain a significant amount of a pollutant, and the combination of such streams, prior to treatment, with an Industrial User's regulated process wastestream(s) will result in a substantial reduction of that pollutant, the Control Authority, upon application of the Industrial User, may exercise its discretion to determine whether such stream(s) should be classified as diluted or unregulated. In its application to the Control Authority, the Industrial User must provide engineering, production, sampling and analysis and such other information so that the Control Authority can make its determination; or (b) sanitary wastestreams where such streams are not regulated by a Categorical Pretreatment Standard; or (c) from any process wastestreams which were or could have been entirely exempted from categorical Pretreatment Standards pursuant to paragraph 8 of the <E T="03">NRDC v. Costle</E> Consent Decree (12 ERC 1833) for one or more of the following reasons (see appendix D of this part):</FP>
          <P>(1) The pollutants of concern are not detectable in the effluent from the Industrial User (paragraph (8)(a)(iii));</P>
          <P>(2) The pollutants of concern are present only in trace amounts and are neither causing nor likely to cause toxic effects (paragraph (8)(a)(iii));</P>
          <P>(3) The pollutants of concern are present in amounts too small to be effectively reduced by technologies known to the Administrator (paragraph (8)(a)(iii)); or</P>

          <P>(4) The wastestream contains only pollutants which are compatible with the POTW (paragraph (8)(b)(i)).<PRTPAGE P="18"/>
          </P>
          <FP SOURCE="FP-1">F<E T="22">T</E>=The average daily flow (at least a 30-day average) through the combined treatment facility (includes F<E T="22">i</E>, F<E T="22">D</E> and unregulated streams).</FP>
          <FP SOURCE="FP-1">N=The total number of regulated streams.</FP>
        </EXTRACT>
        
        <P>(ii) <E T="03">Alternative mass limit.</E>
        </P>
        <MATH DEEP="68" SPAN="1">
          <MID>EC15NO91.013</MID>
        </MATH>
        <EXTRACT>
          <FP>where</FP>
          
          <FP SOURCE="FP-1">M<E T="22">T</E>=the alternative mass limit for a pollutant in the combined wastestream.</FP>
          <FP SOURCE="FP-1">M<E T="22">i</E>=the categorical Pretreatment Standard mass limit for a pollutant in the regulated stream i (the categorical pretreatment mass limit multiplied by the appropriate measure of production).</FP>
          <FP SOURCE="FP-1">F<E T="22">i</E>=the average flow (at least a 30-day average) of stream i to the extent that it is regulated for such pollutant.</FP>
          <FP SOURCE="FP-1">F<E T="52">D=</E>the average daily flow (at least a 30-day average) from: (a) Boiler blowdown streams, non-contact cooling streams, stormwater streams, and demineralizer backwash streams; provided, however, that where such streams contain a significant amount of a pollutant, and the combination of such streams, prior to treatment, with an Industrial User's regulated process wastestream(s) will result in a substantial reduction of that pollutant, the Control Authority, upon application of the Industrial User, may exercise its discretion to determine whether such stream(s) should be classified as diluted or unregulated. In its application to the Control Authority, the Industrial User must provide engineering, production, sampling and analysis and such other information so that the Control Authority can make its determination; or (b) sanitary wastestreams where such streams are not regulated by a categorical Pretreatment Standard; or (c) from any process wastestreams which were or could have been entirely exempted from categorical Pretreatment Standards pursuant to paragraph 8 of the <E T="03">NRDC v. Costle</E> Consent Decree (12 ERC 1833) for one or more of the following reasons (see appendix D of this part):</FP>
          <P>(1) The pollutants of concern are not detectable in the effluent from the Industrial User (paragraph (8)(a)(iii));</P>
          <P>(2) The pollutants of concern are present only in trace amounts and are neither causing nor likely to cause toxic effects (paragraph (8)(a)(iii));</P>
          <P>(3) The pollutants of concern are present in amounts too small to be effectively reduced by technologies known to the Administrator (paragraph (8)(a)(iii)); or</P>
          <P>(4) The wastestream contains only pollutants which are compatible with the POTW (paragraph (8)(b)(i)).</P>
          <FP SOURCE="FP-1">F<E T="22">T</E>=The average flow (at least a 30-day average) through the combined treatment facility (includes F<E T="22">i</E>, F<E T="22">D</E> and unregulated streams).</FP>
          <FP SOURCE="FP-1">N=The total number of regulated streams.</FP>
        </EXTRACT>
        
        <P>(2) <E T="03">Alternate limits below detection limit.</E> An alternative pretreatment limit may not be used if the alternative limit is below the analytical detection limit for any of the regulated pollutants.</P>
        <P>(3) <E T="03">Self-monitoring.</E> Self-monitoring required to insure compliance with the alternative categorical limit shall be conducted in accordance with the requirements of § 403.12(g).</P>
        <P>(4) <E T="03">Choice of monitoring location.</E> Where a treated regulated process wastestream is combined prior to treatment with wastewaters other than those generated by the regulated process, the Industrial User may monitor either the segregated process wastestream or the combined wastestream for the purpose of determining compliance with applicable Pretreatment Standards. If the Industrial User chooses to monitor the segregated process wastestream, it shall apply the applicable categorical Pretreatment Standard. If the User chooses to monitor the combined wastestream, it shall apply an alternative discharge limit calculated using the combined wastestream formula as provided in this section. The Industrial User may change monitoring points only after receiving approval from the Control Authority. The Control Authority shall ensure that any change in an Industrial User's monitoring point(s) will not allow the User to substitute dilution for adequate treatment to achieve compliance with applicable Standards.</P>
        <CITA>[46 FR 9439, Jan. 28, 1981, as amended at 49 FR 21037, May 17, 1984; 49 FR 31224, Aug. 3, 1984; 51 FR 20430, June 4, 1986; 51 FR 23760, July 1, 1986; 53 FR 40610, Oct. 17, 1988; 55 FR 30129, July 24, 1990; 58 FR 18017, Apr. 7, 1993]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 403.7</SECTNO>
        <SUBJECT>Removal credits.</SUBJECT>
        <P>(a) <E T="03">Introduction—</E>(1) <E T="03">Definitions.</E> For the purpose of this section:<PRTPAGE P="19"/>
        </P>
        <P>(i) <E T="03">Removal</E> means a reduction in the amount of a pollutant in the POTW's effluent or alteration of the nature of a pollutant during treatment at the POTW. The reduction or alteration can be obtained by physical, chemical or biological means and may be the result of specifically designed POTW capabilities or may be incidental to the operation of the treatment system. Removal as used in this subpart shall not mean dilution of a pollutant in the POTW.</P>
        <P>(ii) <E T="03">Sludge Requirements</E> shall mean the following statutory provisions and regulations or permits issued thereunder (or more stringent State or local regulations): Section 405 of the Clean Water Act; the Solid Waste Disposal Act (SWDA) (including title II more commonly referred to as the Resource Conservation Recovery Act (RCRA) and State regulations contained in any State sludge management plan prepared pursuant to subtitle D of SWDA); the Clean Air Act; the Toxic Substances Control Act; and the Marine Protection, Research and Sanctuaries Act.</P>
        <P>(2) <E T="03">General.</E> Any POTW receiving wastes from an Industrial User to which a categorical Pretreatment Standard(s) applies may, at its discretion and subject to the conditions of this section, grant removal credits to reflect removal by the POTW of pollutants specified in the categorical Pretreatment Standard(s). The POTW may grant a removal credit equal to or, at its discretion, less than its consistent removal rate. Upon being granted a removal credit, each affected Industrial User shall calculate its revised discharge limits in accordance with paragraph (a)(4) of this section. Removal credits may only be given for indicator or surrogate pollutants regulated in a categorical Pretreatment Standard if the categorical Pretreatment Standard so specifies.</P>
        <P>(3) <E T="03">Conditions for authorization to give removal credits.</E> A POTW is authorized to give removal credits only if the following conditions are met:</P>
        <P>(i) <E T="03">Application.</E> The POTW applies for, and receives, authorization from the Approval Authority to give a removal credit in accordance with the requirements and procedures specified in paragraph (e) of this section.</P>
        <P>(ii) <E T="03">Consistent removal determination.</E> The POTW demonstrates and continues to achieve consistent removal of the pollutant in accordance with paragraph (b) of this section.</P>
        <P>(iii) <E T="03">POTW local pretreatment program.</E> The POTW has an approved pretreatment program in accordance with and to the extent required by part 403; provided, however, a POTW which does not have an approved pretreatment program may, pending approval of such a program, conditionally give credits as provided in paragraph (d) of this section.</P>
        <P>(iv) <E T="03">Sludge requirements.</E> The granting of removal credits will not cause the POTW to violate the local, State and Federal Sludge Requirements which apply to the sludge management method chosen by the POTW. Alternatively, the POTW can demonstrate to the Approval Authority that even though it is not presently in compliance with applicable Sludge Requirements, it will be in compliance when the Industrial User(s) to whom the removal credit would apply is required to meet its categorical Pretreatment Standard(s) as modified by the removal credit. If granting removal credits forces a POTW to incur greater sludge management costs than would be incurred in the absence of granting removal credits, the additional sludge management costs will not be eligible for EPA grant assistance. Removal credits may be made available for the following pollutants.</P>
        <P>(A) For any pollutant listed in appendix G section I of this part for the use or disposal practice employed by the POTW, when the requirements in 40 CFR part 503 for that practice are met.</P>
        <P>(B) For any pollutant listed in appendix G section II of this part for the use or disposal practice employed by the POTW when the concentration for a pollutant listed in appendix G section II of this part in the sewage sludge that is used or disposed does not exceed the concentration for the pollutant in appendix G section II of this part.</P>

        <P>(C) For any pollutant in sewage sludge when the POTW disposes all of its sewage sludge in a municipal solid <PRTPAGE P="20"/>waste landfill unit that meets the criteria in 40 CFR part 258.</P>
        <P>(v) <E T="03">NPDES permit limitations.</E> The granting of removal credits will not cause a violation of the POTW's permit limitations or conditions. Alternatively, the POTW can demonstrate to the Approval Authority that even though it is not presently in compliance with applicable limitations and conditions in its NPDES permit, it will be in compliance when the Industrial User(s) to whom the removal credit would apply is required to meet its categorical Pretreatment Standard(s), as modified by the removal credit provision.</P>
        <P>(4) <E T="03">Calculation of revised discharge limits.</E> Revised discharge limits for a specific pollutant shall be derived by use of the following formula:</P>
        <MATH DEEP="24" SPAN="1">
          <MID>EC15NO91.014</MID>
        </MATH>
        
        <EXTRACT>
          <FP>where:</FP>
          
          <FP SOURCE="FP-1">x=pollutant discharge limit specified in the applicable categorical Pretreatment Standard</FP>
          <FP SOURCE="FP-1">r=removal credit for that pollutant as established under paragraph (b) of this section (percentage removal expressed as a proportion, i.e., a number between 0 and 1)</FP>
          <FP SOURCE="FP-1">y=revised discharge limit for the specified pollutant (expressed in same units as x)</FP>
        </EXTRACT>
        
        <P>(b) <E T="03">Establishment of Removal Credits; Demonstration of Consistent Removal</E>—(1) <E T="03">Definition of Consistent Removal.</E> “Consistent Removal” shall mean the average of the lowest 50 percent of the removal measured according to paragraph (b)(2) of this section. All sample data obtained for the measured pollutant during the time period prescribed in paragraph (b)(2) of this section must be reported and used in computing Consistent Removal. If a substance is measurable in the influent but not in the effluent, the effluent level may be assumed to be the limit of measurement, and those data may be used by the POTW at its discretion and subject to approval by the Approval Authority. If the substance is not measurable in the influent, the date may not be used. Where the number of samples with concentrations equal to or above the limit of measurement is between 8 and 12, the average of the lowest 6 removals shall be used. If there are less than 8 samples with concentrations equal to or above the limit of measurement, the Approval Authority may approve alternate means for demonstrating Consistent Removal. The term “measurement” refers to the ability of the analytical method or protocol to quantify as well as identify the presence of the substance in question.</P>
        <P>(2) <E T="03">Consistent Removal Data.</E> Influent and effluent operational data demonstrating Consistent Removal or other information, as provided for in paragraph (b)(1) of this section, which demonstrates Consistent Removal of the pollutants for which discharge limit revisions are proposed. This data shall meet the following requirements:</P>
        <P>(i) <E T="03">Representative Data; Seasonal.</E> The data shall be representative of yearly and seasonal conditions to which the POTW is subjected for each pollutant for which a discharge limit revision is proposed.</P>
        <P>(ii) <E T="03">Representative Data; Quality and Quantity.</E> The data shall be representative of the quality and quantity of normal effluent and influent flow if such data can be obtained. If such data are unobtainable, alternate data or information may be presented for approval to demonstrate Consistent Removal as provided for in paragraph (b)(1) of this section.</P>
        <P>(iii) <E T="03">Sampling Procedures: Composite.</E> (A) The influent and effluent operational data shall be obtained through 24-hour flow-proportional composite samples. Sampling may be done manually or automatically, and discretely or continuously. For discrete sampling, at least 12 aliquots shall be composited. Discrete sampling may be flow-proportioned either by varying the time interval between each aliquot or the volume of each aliquot. All composites must be flow-proportional to each stream flow at time of collection of influent aliquot or to the total influent flow since the previous influent aliquot. Volatile pollutant aliquots must be combined in the laboratory immediately before analysis.</P>
        <P>(B)(<E T="03">1</E>) Twelve samples shall be taken at approximately equal intervals throughout one full year. Sampling must be evenly distributed over the days of the week so as to include no-<PRTPAGE P="21"/>workdays as well as workdays. If the Approval Authority determines that this schedule will not be most representative of the actual operation of the POTW Treatment Plant, an alternative sampling schedule will be approved.</P>
        <P>(<E T="03">2</E>) In addition, upon the Approval Authority's concurrence, a POTW may utilize an historical data base amassed prior to the effective data of this section provide that such data otherwise meet the requirements of this paragraph. In order for the historical data base to be approved it must present a statistically valid description of daily, weekly and seasonal sewage treatment plant loadings and performance for at least one year.</P>
        <P>(C) Effluent sample collection need not be delayed to compensate for hydraulic detention unless the POTW elects to include detention time compensation or unless the Approval Authority requires detention time compensation. The Approval Authority may require that each effluent sample be taken approximately one detention time later than the corresponding influent sample when failure to do so would result in an unrepresentative portrayal of actual POTW operation. The detention period is to be based on a 24-hour average daily flow value. The average daily flow used will be based upon the average of the daily flows during the same month of the previous year.</P>
        <P>(iv) <E T="03">Sampling Procedures: Grab.</E> Where composite sampling is not an appropriate sampling technique, a grab sample(s) shall be taken to obtain influent and effluent operational data. Collection of influent grab samples should precede collection of effluent samples by approximately one detention period. The detention period is to be based on a 24-hour average daily flow value. The average daily flow used will be based upon the average of the daily flows during the same month of the previous year. Grab samples will be required, for example, where the parameters being evaluated are those, such as cyanide and phenol, which may not be held for any extended period because of biological, chemical or physical interactions which take place after sample collection and affect the results. A grab sample is an individual sample collected over a period of time not exceeding 15 minutes.</P>
        <P>(v) <E T="03">Analytical methods.</E> The sampling referred to in paragraphs (b)(2) (i) through (iv) of this section and an analysis of these samples shall be performed in accordance with the techniques prescribed in 40 CFR part 136 and amendments thereto. Where 40 CFR part 136 does not contain sampling or analytical techniques for the pollutant in question, or where the Administrator determines that the part 136 sampling and analytical techniques are inappropriate for the pollutant in question, sampling and analysis shall be performed using validated analytical methods or any other applicable sampling and analytical procedures, including procedures suggested by the POTW or other parties, approved by the Administrator.</P>
        <P>(vi) <E T="03">Calculation of removal.</E> All data acquired under the provisions of this section must be submitted to the Approval Authority. Removal for a specific pollutant shall be determined either, for each sample, by measuring the difference between the concentrations of the pollutant in the influent and effluent of the POTW and expressing the difference as a percent of the influent concentration, or, where such data cannot be obtained, Removal may be demonstrated using other data or procedures subject to concurrence by the Approval Authority as provided for in paragraph (b)(1) of this section.</P>
        <P>(c) <E T="03">Provisional credits.</E> For pollutants which are not being discharged currently (i.e., new or modified facilities, or production changes) the POTW may apply for authorization to give removal credits prior to the initial discharge of the pollutant. Consistent removal shall be based provisionally on data from treatability studies or demonstrated removal at other treatment facilities where the quality and quantity of influent are similar. Within 18 months after the commencement of discharge of pollutants in question, consistent removal must be demonstrated pursuant to the requirements of paragraph (b) of this section. If, within 18 months after the commencement of the discharge of the pollutant in question, the POTW <PRTPAGE P="22"/>cannot demonstrate consistent removal pursuant to the requirements of paragraph (b) of this section, the authority to grant provisional removal credits shall be terminated by the Approval Authority and all Industrial Users to whom the revised discharge limits had been applied shall achieve compliance with the applicable categorical Pretreatment Standard(s) within a reasonable time, not to exceed the period of time prescribed in the applicable categorical Pretreatment Standard(s), as may be specified by the Approval Authority.</P>
        <P>(d) <E T="03">Exception to POTW Pretreatment Program Requirement.</E> A POTW required to develop a local pretreatment program by § 403.8 may conditionally give removal credits pending approval of such a program in accordance with the following terms and conditions:</P>
        <P>(1) All Industrial Users who are currently subject to a categorical Pretreatment Standard and who wish conditionally to receive a removal credit must submit to the POTW the information required in § 403.12(b)(1) through (7) (except new or modified industrial users must only submit the information required by § 403.12(b)(1) through (6)), pertaining to the categorical Pretreatment Standard as modified by the removal credit. The Industrial Users shall indicate what additional technology, if any, will be needed to comply with the categorical Pretreatment Standard(s) as modified by the removal credit;</P>
        <P>(2) The POTW must have submitted to the Approval Authority an application for pretreatment program approval meeting the requirements of §§ 403.8 and 403.9 in a timely manner, not to exceed the time limitation set forth in a compliance schedule for development of a pretreatment program included in the POTW's NPDES permit, but in no case later than July 1, 1983, where no permit deadline exists;</P>
        <P>(3) The POTW must:</P>
        <P>(i) Compile and submit data demonstrating its consistent removal in accordance with paragraph (b) of this section;</P>
        <P>(ii) Comply with the conditions specified in paragraph (a)(3) of this section; and</P>
        <P>(iii) Submit a complete application for removal credit authority in accordance with paragraph (e) of this section;</P>
        <P>(4) If a POTW receives authority to grant conditional removal credits and the Approval Authority subsequently makes a final determination, after appropriate notice, that the POTW failed to comply with the conditions in paragraphs (d)(2) and (3) of this section, the authority to grant conditional removal credits shall be terminated by the Approval Authority and all —ndustrial Users to whom the revised discharge limits had been applied shall achieve compliance with the applicable categorical Pretreatment Standard(s) within a reasonable time, not to exceed the period of time prescribed in the applicable categorical Pretreatment Standard(s), as may be specified by the Approval Authority.</P>
        <P>(5) If a POTW grants conditional removal credits and the POTW or the Approval Authority subsequently makes a final determination, after appropriate notice, that the Industrial User(s) failed to comply with the conditions in paragraph (d)(1) of this section, the conditional credit shall be terminated by the POTW or the Approval Authority for the non-complying Industrial User(s) and the Industrial User(s) to whom the revised discharge limits had been applied shall achieve compliance with the applicable categorical Pretreatment Standard(s) within a reasonable time, not to exceed the period of time prescribed in the applicable categorical Pretreatment Standard(s), as may be specified by the Approval Authority. The conditional credit shall not be terminated where a violation of the provisions of this paragraph results from causes entirely outside of the control of the Industrial User(s) or the Industrial User(s) had demonstrated substantial compliance.</P>

        <P>(6) The Approval Authority may elect not to review an application for conditional removal credit authority upon receipt of such application, in which case the conditionally revised discharge limits will remain in effect until reviewed by the Approval Authority. This review may occur at any time in accordance with the procedures of § 403.11, but in no event later than the <PRTPAGE P="23"/>time of any pretreatment program approval or any NPDES permit reissuance thereunder.</P>
        <P>(e) <E T="03">POTW application for authorization to give removal credits and Approval Authority review</E>—(1) <E T="03">Who must apply.</E> Any POTW that wants to give a removal credit must apply for authorization from the Approval Authority.</P>
        <P>(2) <E T="03">To whom application is made.</E> An application for authorization to give removal credits (or modify existing ones) shall be submitted by the POTW to the Approval Authority.</P>
        <P>(3) <E T="03">When to apply.</E> A POTW may apply for authorization to give or modify removal credits at any time.</P>
        <P>(4) <E T="03">Contents of the Application.</E> An application for authorization to give removal credits must be supported by the following information:</P>
        <P>(i) <E T="03">List of pollutants.</E> A list of pollutants for which removal credits are proposed.</P>
        <P>(ii) <E T="03">Consistent Removal Data.</E> The data required pursuant to paragraph (b) of this section.</P>
        <P>(iii) <E T="03">Calculation of revised discharge limits.</E> Proposed revised discharge limits for each affected subcategory of Industrial Users calculated in accordance with paragraph (a)(4) of this section.</P>
        <P>(iv) <E T="03">Local Pretreatment Program Certification.</E> A certification that the POTW has an approved local pretreatment program or qualifies for the exception to this requirement found at paragraph (d) of this section.</P>
        <P>(v) <E T="03">Sludge Management Certification.</E> A specific description of the POTW's current methods of using or disposing of its sludge and a certification that the granting of removal credits will not cause a violation of the sludge requirements identified in paragraph (a)(3)(iv) of this section.</P>
        <P>(vi) <E T="03">NPDES Permit Limit Certification.</E> A certification that the granting of removal credits will not cause a violation of the POTW's NPDES permit limits and conditions as required in paragraph (a)(3)(v) of this section.</P>
        <P>(5) <E T="03">Approval Authority Review.</E> The Approval Authority shall review the POTW's application for authorization to give or modify removal credits in accordance with the procedures of § 403.11 and shall, in no event, have more that 180 days from public notice of an application to complete review.</P>
        <P>(6) <E T="03">EPA review of State removal credit approvals.</E> Where the NPDES State has an approved pretreatment program, the Regional Administrator may agree in the Memorandum of Agreement under 40 CFR 123.24(d) to waive the right to review and object to submissions for authority to grant removal credits. Such an agreement shall not restrict the Regional Administrator's right to comment upon or object to permits issued to POTW's except to the extent 40 CFR 123.24(d) allows such restriction.</P>
        <P>(7) Nothing in these regulations precludes an Industrial User or other interested party from assisting the POTW in preparing and presenting the information necessary to apply for authorization.</P>
        <P>(f) <E T="03">Continuation and withdrawal of authorization—</E>(1) <E T="03">Effect of authorization.</E> (i) Once a POTW has received authorization to grant removal credits for a particular pollutant regulated in a categorical Pretreatment Standard it may automatically extend that removal credit to the same pollutant when it is regulated in other categorical standards, unless granting the removal credit will cause the POTW to violate the sludge requirements identified in paragraph (a)(3)(iv) of this section or its NPDES permit limits and conditions as required by paragraph (a)(3)(v) of this section. If a POTW elects at a later time to extend removal credits to a certain categorical Pretreatment Standard, industrial subcategory or one or more Industrial Users that initially were not granted removal credits, it must notify the Approval Authority.</P>
        <P>(2) <E T="03">Inclusion in POTW permit.</E> Once authority is granted, the removal credits shall be included in the POTW's NPDES Permit as soon as possible and shall become an enforceable requirement of the POTW's NPDES permit. The removal credits will remain in effect for the term of the POTW's NPDES permit, provided the POTW maintains compliance with the conditions specified in paragraph (f)(4) of this section.</P>
        <P>(3) <E T="03">Compliance monitoring.</E> Following authorization to give removal credits, <PRTPAGE P="24"/>a POTW shall continue to monitor and report on (at such intervals as may be specified by the Approval Authority, but in no case less than once per year) the POTW's removal capabilities. A minimum of one representative sample per month during the reporting period is required, and all sampling data must be included in the POTW's compliance report.</P>
        <P>(4) <E T="03">Modification or withdrawal of removal credits</E>—(i) <E T="03">Notice of POTW</E>. The Approval Authority shall notify the POTW if, on the basis of pollutant removal capability reports received pursuant to paragraph (f)(3) of this section or other relevant information available to it, the Approval Authority determines:</P>
        <P>(A) That one or more of the discharge limit revisions made by the POTW, of the POTW itself, no longer meets the requirements of this section, or</P>
        <P>(B) That such discharge limit revisions are causing a violation of any conditions or limits contained in the POTW's NPDES Permit.</P>
        <P>(ii) <E T="03">Corrective action.</E> If appropriate corrective action is not taken within a reasonable time, not to exceed 60 days unless the POTW or the affected Industrial Users demonstrate that a longer time period is reasonably necessary to undertake the appropriate corrective action, the Approval Authority shall either withdraw such discharge limits or require modifications in the revised discharge limits.</P>
        <P>(iii) <E T="03">Public notice of withdrawal or modification.</E> The Approval Authority shall not withdraw or modify revised discharge limits unless it shall first have notified the POTW and all Industrial Users to whom revised discharge limits have been applied, and made public, in writing, the reasons for such withdrawal or modification, and an opportunity is provided for a hearing. Following such notice and withdrawal or modification, all Industrial Users to whom revised discharge limits had been applied, shall be subject to the modified discharge limits or the discharge limits prescribed in the applicable categorical Pretreatment Standards, as appropriate, and shall achieve compliance with such limits within a reasonable time (not to exceed the period of time prescribed in the applicable categorical Pretreatment Standard(s) as may be specified by the Approval Authority.</P>
        <P>(g) <E T="03">Removal credits in State-run pretreatment programs under § 403.10(e).</E> Where an NPDES State with an approved pretreatment program elects to implement a local pretreatment program in lieu or requiring the POTW to develop such a program (as provided in § 403.10(e)), the POTW will not be required to develop a pretreatment program as a precondition to obtaining authorization to give removal credits. The POTW will, however, be required to comply with the other conditions of paragraph (a)(3) of this section.</P>
        <P>(h) <E T="03">Compensation for overflow.</E> “Overflow” means the intentional or unintentional diversion of flow from the POTW before the POTW Treatment Plant. POTWs which at least once annually Overflow untreated wastewater to receiving waters may claims Consistent Removal of a pollutant only by complying with either paragraph (h)(1) of (h)(2) or this section. However, this subsection shall not apply where Industrial User(s) can demonstrate that Overflow does not occur between the Industrial User(s) and the POTW Treatment Plant;</P>
        <P>(1) The Industrial User provides containment or otherwise ceases or reduces Discharges from the regulated processes which contain the pollutant for which an allowance is requested during all circumstances in which an Overflow event can reasonably be expected to occur at the POTW or at a sewer to which the Industrial User is connected. Discharges must cease or be reduced, or pretreatment must be increased, to the extent necessary to compensate for the removal not being provided by the POTW. Allowances under this provision will only be granted where the POTW submits to the Approval Authority evidence that:</P>

        <P>(i) All Industrial Users to which the POTW proposes to apply this provision have demonstrated the ability to contain or otherwise cease or reduce, during circumstances in which an Overflow event can reasonably be expected to occur, Discharges from the regulated processes which contain pollutants for which an allowance is requested;<PRTPAGE P="25"/>
        </P>
        <P>(ii) The POTW has identified circumstances in which an Overflow event can reasonably be expected to occur, and has a notification or other viable plan to insure that Industrial Users will learn of an impending Overflow in sufficient time to contain, cease or reduce Discharging to prevent untreated Overflows from occurring. The POTW must also demonstrate that it will monitor and verify the data required in paragraph (h)(1)(iii) of this section, to insure that Industrial Users are containing, ceasing or reducing operations during POTW System Overflow; and</P>
        <P>(iii) All Industrial Users to which the POTW proposes to apply this provision have demonstrated the ability and commitment to collect and make available, upon request by the POTW, State Director or EPA Regional Administrator, daily flow reports or other data sufficient to demonstrate that all Discharges from regulated processes containing the pollutant for which the allowance is requested were contained, reduced or otherwise ceased, as appropriate, during all circumstances in which an Overflow event was reasonably expected to occur; or</P>
        <P>(2)(i) The Consistent Removal claimed is reduced pursuant to the following equation:</P>
        <MATH DEEP="24" SPAN="1">
          <MID>EC15NO91.015</MID>
        </MATH>
        
        <EXTRACT>
          <FP>where:</FP>
          
          <FP SOURCE="FP-1">r<E T="52">m</E> = POTW's Consistent Removal rate for that pollutant as established under paragraphs (a)(1) and (b)(2) of this section</FP>
          <FP SOURCE="FP-1">r<E T="52">c</E> = removal corrected by the Overflow factor</FP>
          <FP SOURCE="FP-1">Z = hours per year that Overflow occurred between the Industrial User(s) and the POTW Treatment Plant, the hours either to be shown in the POTW's current NPDES permit application or the hours, as demonstrated by verifiable techniques, that a particular Industrial User's Discharge Overflows between the Industrial User and the POTW Treatment Plant; and</FP>
        </EXTRACT>
        
        <P>(ii) After July 1, 1983, Consistent Removal may be claimed only where efforts to correct the conditions resulting in untreated Discharges by the POTW are underway in accordance with the policy and procedures set forth in “PRM 75-34” or “Program Guidance Memorandum-61” (same document) published on December 16, 1975, by EPA Office of Water Program Operations (WH-546). (See appendix A.) Revisions to discharge limits in categorical Pretreatment Standards may not be made where efforts have not been committed to by the POTW to minimize pollution from Overflows. At minimum, by July 1, 1983, the POTW must have completed the analysis required by PRM 75-34 and be making an effort to implement the plan.</P>
        <P>(iii) If, by July 1, 1983, a POTW has begun the PRM 75-34 analysis but due to circumstances beyond its control has not completed it, Consistent Removal, subject to the approval of the Approval Authority, may continue to be claimed according to the formula in paragraph (h)(2)(i) of this section as long as the POTW acts in a timely fashion to complete the analysis and makes an effort to implement the non-structural cost-effective measures identified by the analysis; and so long as the POTW has expressed its willingness to apply, after completing the analysis, for a construction grant necessary to implement any other cost-effective Overflow controls identified in the analysis should Federal funds become available, so applies for such funds, and proceeds with the required construction in an expeditious manner. In addition, Consistent Removal may, subject to the approval of the Approval Authority, continue to be claimed according to the formula in paragraph (h)(2)(i) of this section where the POTW has completed and the Approval Authority has accepted the analysis required by PRM 75-34 and the POTW has requested inclusion in its NPDES permit of an acceptable compliance schedule providing for timely implementation of cost-effective measures identified in the analysis. (In considering what is timely implementation, the Approval Authority shall consider the availability of funds, cost of control measures, and seriousness of the water quality problem.)</P>
        <CITA>[49 FR 31221, Aug. 3, 1984, as amended at 51 FR 20430, June 4, 1986; 53 FR 42435, Nov. 5, 1987; 58 FR 9386, Feb. 19, 1993; 58 FR 18017, Apr. 7, 1993]</CITA>
      </SECTION>
      <SECTION>
        <PRTPAGE P="26"/>
        <SECTNO>§ 403.8</SECTNO>
        <SUBJECT>Pretreatment Program Requirements: Development and Implementation by POTW.</SUBJECT>
        <P>(a) <E T="03">POTWs required to develop a pretreatment program</E>. Any POTW (or combination of POTWs operated by the same authority) with a total design flow greater than 5 million gallons per day (mgd) and receiving from Industrial Users pollutants which Pass Through or Interfere with the operation of the POTW or are otherwise subject to Pretreatment Standards will be required to establish a POTW Pretreatment Program unless the NPDES State exercises its option to assume local responsibilities as provided for in § 403.10(e). The Regional Administrator or Director may require that a POTW with a design flow of 5 mgd or less develop a POTW Pretreatment Program if he or she finds that the nature or volume of the industrial influent, treatment process upsets, violations of POTW effluent limitations, contamination of municipal sludge, or other circumstances warrant in order to prevent Interference with the POTW or Pass Through.</P>
        <P>(b) <E T="03">Deadline for Program Approval</E>. A POTW which meets the criteria of paragraph (a) of this section must receive approval of a POTW Pretreatment Program no later than 3 years after the reissuance or modification of its existing NPDES permit but in no case later than July 1, 1983. POTWs whose NPDES permits are modified under section 301(h) of the Act shall have a Pretreatment Program within three (3) years as provided for in 40 CFR part 125, subpart G. POTWs identified after July 1, 1983 as being required to develop a POTW Pretreatment Program under paragraph (a) of this section shall develop and submit such a program for approval as soon as possible, but in no case later than one year after written notification from the Approval Authority of such identification. The POTW Pretreatment Program shall meet the criteria set forth in paragraph (f) of this section and shall be administered by the POTW to ensure compliance by Industrial Users with applicable Pretreatment Standards and Requirements.</P>
        <P>(c) <E T="03">Incorporation of approved programs in permits.</E> A POTW may develop an appropriate POTW Pretreatment Program any time before the time limit set forth in paragraph (b) of this section. The POTW's NPDES Permit will be reissued or modified by the NPDES State or EPA to incorporate the approved Program as enforceable conditions of the Permit. The modification of a POTW's NPDES Permit for the purposes of incorporating a POTW Pretreatment Program approved in accordance with the procedure in § 403.11 shall be deemed a minor Permit modification subject to the procedures in 40 CFR 122.63.</P>
        <P>(d) <E T="03">Incorporation of compliance schedules in permits.</E> [Reserved].</P>
        <P>(e) <E T="03">Cause for reissuance or modification of Permits.</E> Under the authority of section 402(b)(1)(C) of the Act, the Approval Authority may modify, or alternatively, revoke and reissue a POTW's Permit in order to:</P>
        <P>(1) Put the POTW on a compliance schedule for the development of a POTW Pretreatment Program where the addition of pollutants into a POTW by an Industrial User or combination of Industrial Users presents a substantial hazard to the functioning of the treatment works, quality of the receiving waters, human health, or the environment;</P>
        <P>(2) Coordinate the issuance of a section 201 construction grant with the incorporation into a permit of a compliance schedule for POTW Pretreatment Program;</P>
        <P>(3) Incorporate a modification of the permit approved under section 301(h) or 301(i) of the Act;</P>
        <P>(4) Incorporate an approved POTW Pretreatment Program in the POTW permit; or</P>
        <P>(5) Incorporate a compliance schedule for the development of a POTW pretreatment program in the POTW permit.</P>
        <P>(6) Incorporate the removal credits (established under § 403.7) in the POTW permit.</P>
        <P>(f) <E T="03">POTW pretreatment requirements.</E> A POTW pretreatment program must be based on the following legal authority and include the following procedures. These authorities and procedures shall <PRTPAGE P="27"/>at all times be fully and effectively exercised and implemented.</P>
        <P>(1) <E T="03">Legal authority.</E> The POTW shall operate pursuant to legal authority enforceable in Federal, State or local courts, which authorizes or enables the POTW to apply and to enforce the requirements of sections 307 (b) and (c), and 402(b)(8) of the Act and any regulations implementing those sections. Such authority may be contained in a statute, ordinance, or series of contracts or joint powers agreements which the POTW is authorized to enact, enter into or implement, and which are authorized by State law. At a minimum, this legal authority shall enable the POTW to:</P>
        <P>(i) Deny or condition new or increased contributions of pollutants, or changes in the nature of pollutants, to the POTW by Industrial Users where such contributions do not meet applicable Pretreatment Standards and Requirements or where such contributions would cause the POTW to violate its NPDES permit;</P>
        <P>(ii) Require compliance with applicable Pretreatment Standards and Requirements by Industrial Users;</P>
        <P>(iii) Control through permit, order, or similar means, the contribution to the POTW by each Industrial User to ensure compliance with applicable Pretreatment Standards and Requirements. In the case of Industrial Users identified as significant under 40 CFR 403.3(t), this control shall be achieved through permits or equivalent individual control mechanisms issued to each such user. Such control mechanisms must be enforceable and contain, at a minimum, the following conditions:</P>
        <P>(A) Statement of duration (in no case more than five years);</P>
        <P>(B) Statement of non-transferability without, at a minimum, prior notification to the POTW and provision of a copy of the existing control mechanism to the new owner or operator;</P>
        <P>(C) Effluent limits based on applicable general pretreatment standards in part 403 of this chapter, categorical pretreatment standards, local limits, and State and local law;</P>
        <P>(D) Self-monitoring, sampling, reporting, notification and recordkeeping requirements, including an identification of the pollutants to be monitored, sampling location, sampling frequency, and sample type, based on the applicable general pretreatment standards in part 403 of this chapter, categorical pretreatment standards, local limits, and State and local law;</P>
        <P>(E) Statement of applicable civil and criminal penalties for violation of pretreatment standards and requirements, and any applicable compliance schedule. Such schedules may not extend the compliance date beyond applicable federal deadlines.</P>
        <P>(iv) Require (A) the development of a compliance schedule by each Industrial User for the installation of technology required to meet applicable Pretreatment Standards and Requirements and (B) the submission of all notices and self-monitoring reports from Industrial Users as are necessary to assess and assure compliance by Industrial Users with Pretreatment Standards and Requirements, including but not limited to the reports required in § 403.12.</P>
        <P>(v) Carry out all inspection, surveillance and monitoring procedures necessary to determine, independent of information supplied by Industrial Users, compliance or noncompliance with applicable Pretreatment Standards and Requirements by Industrial Users. Representatives of the POTW shall be authorized to enter any premises of any Industrial User in which a Discharge source or treatment system is located or in which records are required to be kept under § 403.12(m) to assure compliance with Pretreatment Standards. Such authority shall be at least as extensive as the authority provided under section 308 of the Act;</P>
        <P>(vi)(A) Obtain remedies for noncompliance by any Industrial User with any Pretreatment Standard and Requirement. All POTW's shall be able to seek injunctive relief for noncompliance by Industrial Users with Pretreatment Standards and Requirements. All POTWs shall also have authority to seek or assess civil or criminal penalties in at least the amount of $1,000 a day for each violation by Industrial Users of Pretreatment Standards and Requirements.</P>

        <P>(B) Pretreatment requirements which will be enforced through the remedies <PRTPAGE P="28"/>set forth in paragraph (f)(1)(vi)(A) of this section, will include but not be limited to, the duty to allow or carry out inspections, entry, or monitoring activities; any rules, regulations, or orders issued by the POTW; any requirements set forth in individual control mechanisms issued by the POTW; or any reporting requirements imposed by the POTW or these regulations. The POTW shall have authority and procedures (after informal notice to the discharger) immediately and effectively to halt or prevent any discharge of pollutants to the POTW which reasonably appears to present an imminent endangerment to the health or welfare of persons. The POTW shall also have authority and procedures (which shall include notice to the affected industrial users and an opportunity to respond) to halt or prevent any discharge to the POTW which presents or may present an endangerment to the environment or which threatens to interfere with the operation of the POTW. The Approval Authority shall have authority to seek judicial relief and may also use administrative penalty authority when the POTW has sought a monetary penalty which the Approval Authority believes to be insufficient.</P>
        <P>(vii) Comply with the confidentiality requirements set forth in § 403.14.</P>
        <P>(2) <E T="03">Procedures.</E> The POTW shall develop and implement procedures to ensure compliance with the requirements of a Pretreatment Program. At a minimum, these procedures shall enable the POTW to:</P>
        <P>(i) Identify and locate all possible Industrial Users which might be subject to the POTW Pretreatment Program. Any compilation, index or inventory of Industrial Users made under this paragraph shall be made available to the Regional Administrator or Director upon request;</P>
        <P>(ii) Identify the character and volume of pollutants contributed to the POTW by the Industrial Users identified under paragraph (f)(2)(i) of this section. This information shall be made available to the Regional Administrator or Director upon request;</P>
        <P>(iii) Notify Industrial Users identified under paragraph (f)(2)(i) of this section, of applicable Pretreatment Standards and any applicable requirements under sections 204(b) and 405 of the Act and subtitles C and D of the Resource Conservation and Recovery Act. Within 30 days of approval pursuant to 40 CFR 403.8(f)(6), of a list of significant industrial users, notify each significant industrial user of its status as such and of all requirements applicable to it as a result of such status.</P>
        <P>(iv) Receive and analyze self-monitoring reports and other notices submitted by Industrial Users in accordance with the self-monitoring requirements in § 403.12;</P>
        <P>(v) Randomly sample and analyze the effluent from industrial users and conduct surveillance activities in order to identify, independent of information supplied by industrial users, occasional and continuing noncompliance with pretreatment standards. Inspect and sample the effluent from each Significant Industrial User at least once a year. Evaluate, at least once every two years, whether each such Significant Industrial User needs a plan to control slug discharges. For purposes of this subsection, a slug discharge is any discharge of a non-routine, episodic nature, including but not limited to an accidental spill or a non-customary batch discharge. The results of such activities shall be available to the Approval Authority upon request. If the POTW decides that a slug control plan is needed, the plan shall contain, at a minimum, the following elements:</P>
        <P>(A) Description of discharge practices, including non-routine batch discharges;</P>
        <P>(B) Description of stored chemicals;</P>
        <P>(C) Procedures for immediately notifying the POTW of slug discharges, including any discharge that would violate a prohibition under 40 CFR 403.5(b), with procedures for follow-up written notification within five days;</P>

        <P>(D) If necessary, procedures to prevent adverse impact from accidental spills, including inspection and maintenance of storage areas, handling and transfer of materials, loading and unloading operations, control of plant site run-off, worker training, building of containment structures or equipment, measures for containing toxic organic pollutants (including solvents), and/or measures and equipment for emergency response;<PRTPAGE P="29"/>
        </P>
        <P>(vi) Investigate instances of noncompliance with Pretreatment Standards and Requirements, as indicated in the reports and notices required under § 403.12, or indicated by analysis, inspection, and surveillance activities described in paragraph (f)(2)(v) of this section. Sample taking and analysis and the collection of other information shall be performed with sufficient care to produce evidence admissible in enforcement proceedings or in judicial actions; and</P>
        <P>(vii) Comply with the public participation requirements of 40 CFR part 25 in the enforcement of national pretreatment standards. These procedures shall include provision for at least annual public notification, in the largest daily newspaper published in the municipality in which the POTW is located, of industrial users which, at any time during the previous twelve months, were in significant noncompliance with applicable pretreatment requirements. For the purposes of this provision, an industrial user is in significant noncompliance if its violation meets one or more of the following criteria:</P>
        <P>(A) Chronic violations of wastewater discharge limits, defined here as those in which sixty-six percent or more of all of the measurements taken during a six-month period exceed (by any magnitude) the daily maximum limit or the average limit for the same pollutant parameter;</P>
        <P>(B) Technical Review Criteria (TRC) violations, defined here as those in which thirty-three percent or more of all of the measurements for each pollutant parameter taken during a six-month period equal or exceed the product of the daily maximum limit or the average limit multiplied by the applicable TRC (TRC=1.4 for BOD, TSS, fats, oil, and grease, and 1.2 for all other pollutants except pH.</P>
        <P>(C) Any other violation of a pretreatment effluent limit (daily maximum or longer-term average) that the Control Authority determines has caused, alone or in combination with other discharges, interference or pass through (including endangering the health of POTW personnel or the general public);</P>
        <P>(D) Any discharge of a pollutant that has caused imminent endangerment to human health, welfare or to the environment or has resulted in the POTW's exercise of its emergency authority under paragraph (f)(1)(vi)(B) of this section to halt or prevent such a discharge;</P>
        <P>(E) Failure to meet, within 90 days after the schedule date, a compliance schedule milestone contained in a local control mechanism or enforcement order for starting construction, completing construction, or attaining final compliance;</P>
        <P>(F) Failure to provide, within 30 days after the due date, required reports such as baseline monitoring reports, 90-day compliance reports, periodic self-monitoring reports, and reports on compliance with compliance schedules;</P>
        <P>(G) Failure to accurately report noncompliance;</P>
        <P>(H) Any other violation or group of violations which the Control Authority determines will adversely affect the operation or implementation of the local pretreatment program.</P>
        <P>(3) <E T="03">Funding.</E> The POTW shall have sufficient resources and qualified personnel to carry out the authorities and procedures described in paragraphs (f) (1) and (2) of this section. In some limited circumstances, funding and personnel may be delayed where (i) the POTW has adequate legal authority and procedures to carry out the Pretreatment Program requirements described in this section, and (ii) a limited aspect of the Program does not need to be implemented immediately (see § 403.9(b)).</P>
        <P>(4) <E T="03">Local limits.</E> The POTW shall develop local limits as required in § 403.5(c)(1), or demonstrate that they are not necessary.</P>
        <P>(5) The POTW shall develop and implement an enforcement response plan. This plan shall contain detailed procedures indicating how a POTW will investigate and respond to instances of industrial user noncompliance. The plan shall, at a minimum:</P>
        <P>(i) Describe how the POTW will investigate instances of noncompliance;</P>

        <P>(ii) Describe the types of escalating enforcement responses the POTW will take in response to all anticipated types of industrial user violations and <PRTPAGE P="30"/>the time periods within which responses will take place;</P>
        <P>(iii) Identify (by title) the official(s) responsible for each type of response;</P>
        <P>(iv) Adequately reflect the POTW's primary responsibility to enforce all applicable pretreatment requirements and standards, as detailed in 40 CFR 403.8 (f)(1) and (f)(2).</P>
        <P>(6) The POTW shall prepare and maintain a list of its industrial users meeting the criteria in § 403.3(u)(1). The list shall identify the criteria in § 403.3(u)(1) applicable to each industrial user and, for industrial users meeting the criteria in § 403.3(u)(ii), shall also indicate whether the POTW has made a determination pursuant to § 403.3(u)(2) that such industrial user should not be considered a significant industrial user. The initial list shall be submitted to the Approval Authority pursuant to § 403.9 as a non-substantial modification pursuant to § 403.18(d). Modifications to the list shall be submitted to the Approval Authority pursuant to § 403.12(i)(1).</P>
        <CITA>[46 FR 9439, Jan. 28, 1981, as amended at 49 FR 31224, Aug. 3, 1984; 51 FR 20429, 20430, June 4, 1986; 51 FR 23759, July 1, 1986; 53 FR 40612, Oct. 17, 1988; 55 FR 30129, July 24, 1990; 58 FR 18017, Apr. 7, 1993; 60 FR 33932, June 29, 1995; 62 FR 38414, July 17, 1997]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 403.9</SECTNO>
        <SUBJECT>POTW pretreatment programs and/or authorization to revise pretreatment standards: Submission for approval.</SUBJECT>
        <P>(a) <E T="03">Who approves Program.</E> A POTW requesting approval of a POTW Pretreatment Program shall develop a program description which includes the information set forth in paragraphs (b)(1) through (4) of this section. This description shall be submitted to the Approval Authority which will make a determination on the request for program approval in accordance with the procedures described in § 403.11.</P>
        <P>(b) <E T="03">Contents of POTW program submission.</E> The program description must contain the following information:</P>
        <P>(1) A statement from the City Solicitor or a city official acting in a comparable capacity (or the attorney for those POTWs which have independent legal counsel) that the POTW has authority adequate to carry out the programs described in § 403.8. This statement shall:</P>
        <P>(i) Identify the provision of the legal authority under § 403.8(f)(1) which provides the basis for each procedure under § 403.8(f)(2);</P>
        <P>(ii) Identify the manner in which the POTW will implement the program requirements set forth in § 403.8, including the means by which Pretreatment Standards will be applied to individual Industrial Users (e.g., by order, permit, ordinance, etc.); and,</P>
        <P>(iii) Identify how the POTW intends to ensure compliance with Pretreatment Standards and Requirements, and to enforce them in the event of noncompliance by Industrial Users;</P>
        <P>(2) A copy of any statutes, ordinances, regulations, agreements, or other authorities relied upon by the POTW for its administration of the Program. This Submission shall include a statement reflecting the endorsement or approval of the local boards or bodies responsible for supervising and/or funding the POTW Pretreatment Program if approved;</P>
        <P>(3) A brief description (including organization charts) of the POTW organization which will administer the Pretreatment Program. If more than one agency is responsible for administration of the Program the responsible agencies should be identified, their respective responsibilities delineated, and their procedures for coordination set forth; and</P>
        <P>(4) A description of the funding levels and full- and part-time manpower available to implement the Program;</P>
        <P>(c) <E T="03">Conditional POTW program approval.</E> The POTW may request conditional approval of the Pretreatment Program pending the acquisition of funding and personnel for certain elements of the Program. The request for conditional approval must meet the requirements set forth in paragraph (b) of this section except that the requirements of paragraph (b) of this section, may be relaxed if the Submission demonstrates that:</P>
        <P>(1) A limited aspect of the Program does not need to be implemented immediately;</P>

        <P>(2) The POTW had adequate legal authority and procedures to carry out those aspects of the Program which <PRTPAGE P="31"/>will not be implemented immediately; and</P>
        <P>(3) Funding and personnel for the Program aspects to be implemented at a later date will be available when needed. The POTW will describe in the Submission the mechanism by which this funding will be acquired. Upon receipt of a request for conditional approval, the Approval Authority will establish a fixed date for the acquisition of the needed funding and personnel. If funding is not acquired by this date, the conditional approval of the POTW Pretreatment Program and any removal allowances granted to the POTW, may be modified or withdrawn.</P>
        <P>(d) <E T="03">Content of removal allowance submission.</E> The request for authority to revise categorical Pretreatment Standards must contain the information required in § 403.7(d).</P>
        <P>(e) <E T="03">Approval authority action.</E> Any POTW requesting POTW Pretreatment Program approval shall submit to the Approval Authority three copies of the Submission described in paragraph (b), and if appropriate, (d) of this section. Within 60 days after receiving the Submission, the Approval Authority shall make a preliminary determination of whether the Submission meets the requirements of paragraph (b) and, if appropriate, (d) of this section. If the Approval Authority makes the preliminary determination that the Submission meets these requirements, the Approval Authority shall:</P>
        <P>(1) Notify the POTW that the Submission has been received and is under review; and</P>
        <P>(2) Commence the public notice and evaluation activities set forth in § 403.11.</P>
        <P>(f) <E T="03">Notification where submission is defective.</E> If, after review of the Submission as provided for in paragraph (e) of this section, the Approval Authority determines that the Submission does not comply with the requirements of paragraph (b) or (c) of this section, and, if appropriate, paragraph (d), of this section, the Approval Authority shall provide notice in writing to the applying POTW and each person who has requested individual notice. This notification shall identify any defects in the Submission and advise the POTW and each person who has requested individual notice of the means by which the POTW can comply with the applicable requirements of paragraphs (b), (c) of this section, and, if appropriate, paragraph (d) of this section.</P>
        <P>(g) <E T="03">Consistency with water quality management plans.</E> (1) In order to be approved the POTW Pretreatment Program shall be consistent with any approved water quality management plan developed in accordance with 40 CFR parts 130, 131, as revised, where such 208 plan includes Management Agency designations and addresses pretreatment in a manner consistent with 40 CFR part 403. In order to assure such consistency the Approval Authority shall solicit the review and comment of the appropriate 208 Planning Agency during the public comment period provided for in § 403.11(b)(1)(ii) prior to approval or disapproval of the Program.</P>
        <P>(2) Where no 208 plan has been approved or where a plan has been approved but lacks Management Agency designations and/or does not address pretreatment in a manner consistent with this regulation, the Approval Authority shall nevertheless solicit the review and comment of the appropriate 208 planning agency.</P>
        <CITA>[53 FR 9439, Jan. 28, 1981, as amended at 53 FR 40612, Oct. 17, 1988; 58 FR 18017, Apr. 7, 1993]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 403.10</SECTNO>
        <SUBJECT>Development and submission of NPDES State pretreatment programs.</SUBJECT>
        <P>(a) <E T="03">Approval of State Programs.</E> No State NPDES program shall be approved under section 402 of the Act after the effective date of these regulations unless it is determined to meet the requirements of paragraph (f) of this section. Notwithstanding any other provision of this regulation, a State will be required to act upon those authorities which it currently possesses before the approval of a State Pretreatment Program.</P>
        <P>(b) [Reserved]</P>
        <P>(c) <E T="03">Failure to request approval.</E> Failure of an NPDES State with a permit program approved under section 402 of the Act prior to December 27, 1977, to seek approval of a State Pretreatment Program and failure of an approved State to administer its State Pretreatment <PRTPAGE P="32"/>Program in accordance with the requirements of this section constitutes grounds for withdrawal of NPDES program approval under section 402(c)(3) of the Act.</P>
        <P>(d) [Reserved]</P>
        <P>(e) <E T="03">State Program in lieu of POTW Program.</E> Notwithstanding the provision of § 403.8(a), a State with an approved Pretreatment Program may assume responsibility for implementing the POTW Pretreatment Program requirements set forth in § 403.8(f) in lieu of requiring the POTW to develop a Pretreatment Program. However, this does not preclude POTW's from independently developing Pretreatment Programs.</P>
        <P>(f) <E T="03">State Pretreatment Program requirements.</E> In order to be approved, a request for State Pretreatment Program Approval must demonstrate that the State Pretreatment Program has the following elements:</P>
        <P>(1) <E T="03">Legal authority.</E> The Attorney General's Statement submitted in accordance with paragraph (g)(1)(i) of this section shall certify that the Director has authority under State law to operate and enforce the State Pretreatment Program to the extent required by this part and by 40 CFR 123.27. At a minimum, the Director shall have the authority to:</P>
        <P>(i) Incorporate POTW Pretreatment Program conditions into permits issued to POTW's; require compliance by POTW's with these incorporated permit conditions; and require compliance by Industrial Users with Pretreatment Standards;</P>
        <P>(ii) Ensure continuing compliance by POTW's with pretreatment conditions incorporated into the POTW Permit through review of monitoring reports submitted to the Director by the POTW in accordance with § 403.12 and ensure continuing compliance by Industrial Users with Pretreatment Standards through the review of self-monitoring reports submitted to the POTW or to the Director by the Industrial Users in accordance with § 403.12;</P>
        <P>(iii) Carry out inspection, surveillance and monitoring procedures which will determine, independent of information supplied by the POTW, compliance or noncompliance by the POTW with pretreatment conditions incorporated into the POTW Permit; and carry out inspection, surveillance and monitoring procedures which will determine, independent of information supplied by the Industrial User, whether the Industrial User is in compliance with Pretreatment Standards;</P>
        <P>(iv) Seek civil and criminal penalties, and injunctive relief, for noncompliance by the POTW with pretreatment conditions incorporated into the POTW Permit and for noncompliance with Pretreatment Standards by Industrial Users as set forth in § 403.8(f)(1)(vi). The Director shall have authority to seek judicial relief for noncompliance by Industrial Users even when the POTW has acted to seek such relief (e.g., if the POTW has sought a penalty which the Director finds to be insufficient);</P>
        <P>(v) Approve and deny requests for approval of POTW Pretreatment Programs submitted by a POTW to the Director;</P>
        <P>(vi) Deny and recommend approval of (but not approve) requests for Fundamentally Different Factors variances submitted by Industrial Users in accordance with the criteria and procedures set forth in § 403.13; and</P>
        <P>(vii) Approve and deny requests for authority to modify categorical Pretreatment Standards to reflect removals achieved by the POTW in accordance with the criteria and procedures set forth in §§ 403.7, 403.9 and 403.11.</P>
        <P>(2) <E T="03">Procedures.</E> The Director shall have developed procedures to carry out the requirements of sections 307 (b) and (c), and 402(b)(1), 402(b)(2), 402(b)(8), and 402(b)(9) of the Act. At a minimum, these procedures shall enable the Director to:</P>
        <P>(i) Identify POTW's required to develop Pretreatment Programs in accordance with § 403.8(a) and notify these POTW's of the need to develop a POTW Pretreatment Program. In the absence of a POTW Pretreatment Program, the State shall have procedures to carry out the activities set forth in § 403.8(f)(2);</P>
        <P>(ii) Provide technical and legal assistance to POTW's in developing Pretreatment Programs;</P>

        <P>(iii) Develop compliance schedules for inclusion in POTW Permits which set forth the shortest reasonable time <PRTPAGE P="33"/>schedule for the completion of tasks needed to implement a POTW Pretreatment Program. The final compliance date in these schedules shall be no later than July 1, 1983;</P>
        <P>(iv) Sample and analyze:</P>
        <P>(A) Influent and effluent of the POTW to identify, independent of information supplied by the POTW, compliance or noncompliance with pollutant removal levels set forth in the POTW permit (see § 403.7); and</P>
        <P>(B) The contents of sludge from the POTW and methods of sludge disposal and use to identify, independent of information supplied by the POTW, compliance or noncompliance with requirements applicable to the selected method of sludge management;</P>
        <P>(v) Investigate evidence of violations of pretreatment conditions set forth in the POTW Permit by taking samples and acquiring other information as needed. This data acquisition shall be performed with sufficient care as to produce evidence admissible in an enforcement proceeding or in court;</P>
        <P>(vi) Review and approve requests for approval of POTW Pretreatment Programs and authority to modify categorical Pretreatment Standards submitted by a POTW to the Director; and</P>
        <P>(vii) Consider requests for Fundamentally Different Factors variances submitted by Industrial Users in accordance with the criteria and procedures set forth in § 403.13.</P>
        <P>(3) <E T="03">Funding.</E> The Director shall assure that funding and qualified personnel are available to carry out the authorities and procedures described in paragraphs (f)(1) and (2) of this section.</P>
        <P>(g) <E T="03">Content of State Pretreatment Program submission.</E> The request for State Pretreatment Program approval will consist of:</P>
        <P>(1)(i) A statement from the State Attorney General (or the Attorney for those State agencies which have independent legal counsel) that the laws of the State provide adequate authority to implement the requirements of this part. The authorities cited by the Attorney General in this statement shall be in the form of lawfully adopted State statutes or regulations which shall be effective by the time of approval of the State Pretreatment Program; and</P>
        <P>(ii) Copies of all State statutes and regulations cited in the above statement;</P>
        <P>(iii) States with approved Pretreatment Programs shall establish Pretreatment regulations by November 16, 1989, unless the State would be required to enact or amend statutory provision, in which case, such regulations must be established by November 16, 1990.</P>
        <P>(2) A description of the funding levels and full- and part-time personnel available to implement the program; and</P>
        <P>(3) Any modifications or additions to the Memorandum of Agreement (required by 40 CFR 123.24) which may be necessary for EPA and the State to implement the requirements of this part.</P>
        <P>(h) <E T="03">EPA Action.</E> Any approved NPDES State requesting State Pretreatment Program approval shall submit to the Regional Administrator three copies of the Submission described in paragraph (g) of this section. Upon a preliminary determination that the Submission meets the requirements of paragraph (g) the Regional Administrator shall:</P>
        <P>(1) Notify the Director that the Submission has been received and is under review; and</P>
        <P>(2) Commence the program revision process set out in 40 CFR 123.62. For purposes of that section all requests for approval of State Pretreatment Programs shall be deemed substantial program modifications. A comment period of at least 30 days and the opportunity for a hearing shall be afforded the public on all such proposed program revisions.</P>
        <P>(i) <E T="03">Notification where submission is defective.</E> If, after review of the Submission as provided for in paragraph (h) of this section, EPA determines that the Submission does not comply with the requirements of paragraph (f) or (g) of this section EPA shall so notify the applying NPDES State in writing. This notification shall identify any defects in the Submission and advise the NPDES State of the means by which it can comply with the requirements of this part.</P>
        <CITA>[46 FR 9439, Jan. 28, 1981, as amended at 51 FR 20429, June 4, 1986; 53 FR 40612, Oct. 17, 1988; 55 FR 30131, July 24, 1990; 58 FR 18017, Apr. 7, 1993; 60 FR 33932, June 29, 1995]</CITA>
      </SECTION>
      <SECTION>
        <PRTPAGE P="34"/>
        <SECTNO>§ 403.11</SECTNO>
        <SUBJECT>Approval procedures for POTW pretreatment programs and POTW granting of removal credits.</SUBJECT>
        <P>The following procedures shall be adopted in approving or denying requests for approval of POTW Pretreatment Programs and applications for removal credit authorization:</P>
        <P>(a) <E T="03">Deadline for review of submission.</E> The Approval Authority shall have 90 days from the date of public notice of any Submission complying with the requirements of § 403.9(b) and, where removal credit authorization is sought with §§ 403.7(e) and 403.9(d), to review the Submission. The Approval Authority shall review the Submission to determine compliance with the requirements of § 403.8 (b) and (f), and, where removal credit authorization is sought, with § 403.7. The Approval Authority may have up to an additional 90 days to complete the evaluation of the Submission if the public comment period provided for in paragraph (b)(1)(ii) of this section is extended beyond 30 days or if a public hearing is held as provided for in paragraph (b)(2) of this section. In no event, however, shall the time for evaluation of the Submission exceed a total of 180 days from the date of public notice of a Submission meeting the requirements of § 403.9(b) and, in the case of a removal credit application, §§ 403.7(e) and 403.9(b).</P>
        <P>(b) <E T="03">Public notice and opportunity for hearing.</E> Upon receipt of a Submission the Approval Authority shall commence its review. Within 20 work days after making a determination that a Submission meets the requirements of § 403.9(b) and, where removal allowance approval is sought, §§ 403.7(d) and 403.9(d), the Approval Authority shall:</P>
        <P>(1) Issue a public notice of request for approval of the Submission;</P>
        <P>(i) This public notice shall be circulated in a manner designed to inform interested and potentially interested persons of the Submission. Procedures for the circulation of public notice shall include:</P>
        <P>(A) Mailing notices of the request for approval of the Submission to designated 208 planning agencies, Federal and State fish, shellfish and wildfish resource agencies (unless such agencies have asked not to be sent the notices); and to any other person or group who has requested individual notice, including those on appropriate mailing lists; and</P>
        <P>(B) Publication of a notice of request for approval of the Submission in a newspaper(s) of general circulation within the jurisdiction(s) served by the POTW that meaningful public notice.</P>
        <P>(ii) The public notice shall provide a period of not less than 30 days following the date of the public notice during which time interested persons may submit their written views on the Submission.</P>
        <P>(iii) All written comments submitted during the 30 day comment period shall be retained by the Approval Authority and considered in the decision on whether or not to approve the Submission. The period for comment may be extended at the discretion of the Approval Authority; and</P>
        <P>(2) Provide an opportunity for the applicant, any affected State, any interested State or Federal agency, person or group of persons to request a public hearing with respect to the Submission.</P>
        <P>(i) This request for public hearing shall be filed within the 30 day (or extended) comment period described in paragraph (b)(1)(ii) of this section and shall indicate the interest of the person filing such request and the reasons why a hearing is warranted.</P>
        <P>(ii) The Approval Authority shall hold a hearing if the POTW so requests. In addition, a hearing will be held if there is a significant public interest in issues relating to whether or not the Submission should be approved. Instances of doubt should be resolved in favor of holding the hearing.</P>
        <P>(iii) Public notice of a hearing to consider a Submission and sufficient to inform interested parties of the nature of the hearing and the right to participate shall be published in the same newspaper as the notice of the original request for approval of the Submission under paragraph (b)(1)(i)(B) of this section. In addition, notice of the hearing shall be sent to those persons requesting individual notice.</P>
        <P>(c) <E T="03">Approval authority decision.</E> At the end of the 30 day (or extended) comment period and within the 90 day (or extended) period provided for in paragraph (a) of this section, the Approval <PRTPAGE P="35"/>Authority shall approve or deny the Submission based upon the evaluation in paragraph (a) of this section and taking into consideration comments submitted during the comment period and the record of the public hearing, if held. Where the Approval Authority makes a determination to deny the request, the Approval Authority shall so notify the POTW and each person who has requested individual notice. This notification shall include suggested modifications and the Approval Authority may allow the requestor additional time to bring the Submission into compliance with applicable requirements.</P>
        <P>(d) <E T="03">EPA objection to Director's decision.</E> No POTW pretreatment program or authorization to grant removal allowances shall be approved by the Director if following the 30 day (or extended) evaluation period provided for in paragraph (b)(1)(ii) of this section and any hearing held pursuant to paragraph (b)(2) of this section the Regional Administrator sets forth in writing objections to the approval of such Submission and the reasons for such objections. A copy of the Regional Administrator's objections shall be provided to the applicant, and each person who has requested individual notice. The Regional Administrator shall provide an opportunity for written comments and may convene a public hearing on his or her objections. Unless retracted, the Regional Administrator's objections shall constitute a final ruling to deny approval of a POTW pretreatment program or authorization to grant removal allowances 90 days after the date the objections are issued.</P>
        <P>(e) <E T="03">Notice of decision</E>. The Approval Authority shall notify those persons who submitted comments and participated in the public hearing, if held, of the approval or disapproval of the Submission. In addition, the Approval Authority shall cause to be published a notice of approval or disapproval in the same newspapers as the original notice of request for approval of the Submission was published. The Approval Authority shall identify in any notice of POTW Pretreatment Program approval any authorization to modify categorical Pretreatment Standards which the POTW may make, in accordance with § 403.7, for removal of pollutants subject to Pretreatment Standards.</P>
        <P>(f) <E T="03">Public access to submission</E>. The Approval Authority shall ensure that the Submission and any comments upon such Submission are available to the public for inspection and copying.</P>
        <CITA>[46 FR 9439, Jan. 28, 1981, as amended at 49 FR 31224, Aug. 3, 1984; 51 FR 20429, June 4, 1986; 53 FR 40613, Oct. 17, 1988; 62 FR 38414, July 17, 1997]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 403.12</SECTNO>
        <SUBJECT>Reporting requirements for POTW's and industrial users.</SUBJECT>
        <P>(a) <E T="03">Definition</E>. The term <E T="03">Control Authority</E> as it is used in this section refers to: (1) The POTW if the POTW's Submission for its pretreatment program (§ 403.3(t)(1)) has been approved in accordance with the requirements of § 403.11; or (2) the Approval Authority if the Submission has not been approved.</P>
        <P>(b) <E T="03">Reporting requirements for industrial users upon effective date of categorical pretreatment standard—baseline report.</E> Within 180 days after the effective date of a categorical Pretreatment Standard, or 180 days after the final administrative decision made upon a category determination submission under § 403.6(a)(4), whichever is later, existing Industrial Users subject to such categorical Pretreatment Standards and currently discharging to or scheduled to discharge to a POTW shall be required to submit to the Control Authority a report which contains the information listed in paragraphs (b)(1)-(7) of this section. At least 90 days prior to commencement of discharge, New Sources, and sources that become Industrial Users subsequent to the promulgation of an applicable categorical Standard, shall be required to submit to the Control Authority a report which contains the information listed in paragraphs (b)(1)-(5) of this section. New sources shall also be required to include in this report information on the method of pretreatment the source intends to use to meet applicable pretreatment standards. New Sources shall give estimates of the information requested in paragraphs (b) (4) and (5) of this section:</P>
        <P>(1) <E T="03">Identifying information</E>. The User shall submit the name and address of the facility including the name of the operator and owners;<PRTPAGE P="36"/>
        </P>
        <P>(2) <E T="03">Permits</E>. The User shall submit a list of any environmental control permits held by or for the facility;</P>
        <P>(3) <E T="03">Description of operations</E>. The User shall submit a brief description of the nature, average rate of production, and Standard Industrial Classification of the operation(s) carried out by such Industrial User. This description should include a schematic process diagram which indicates points of Discharge to the POTW from the regulated processes.</P>
        <P>(4) <E T="03">Flow measurement</E>. The User shall submit information showing the measured average daily and maximum daily flow, in gallons per day, to the POTW from each of the following:</P>
        <P>(i) Regulated process streams; and</P>
        <P>(ii) Other streams as necessary to allow use of the combined wastestream formula of § 403.6(e). (See paragraph (b)(5)(v) of this section.)</P>
        <FP>The Control Authority may allow for verifiable estimates of these flows where justified by cost or feasibility considerations.</FP>
        <P>(5) <E T="03">Measurement of pollutants.</E> (i) The user shall identify the Pretreatment Standards applicable to each regulated process;</P>
        <P>(ii) In addition, the User shall submit the results of sampling and analysis identifying the nature and concentration (or mass, where required by the Standard or Control Authority) of regulated pollutants in the Discharge from each regulated process. Both daily maximum and average concentration (or mass, where required) shall be reported. The sample shall be representative of daily operations;</P>
        <P>(iii) A minimum of four (4) grab samples must be used for pH, cyanide, total phenols, oil and grease, sulfide, and volatile organics. For all other pollutants, 24-hour composite samples must be obtained through flow-proportional composite sampling techniques where feasible. The Control Authority may waive flow-proportional composite sampling for any Industrial User that demonstrates that flow-proportional sampling is infeasible. In such cases, samples may be obtained through time-proportional composite sampling techniques or through a minimum of four (4) grab samples where the User demonstrates that this will provide a representative sample of the effluent being discharged.</P>
        <P>(iv) The User shall take a minimum of one representative sample to compile that data necessary to comply with the requirements of this paragraph.</P>
        <P>(v) Samples should be taken immediately downstream from pretreatment facilities if such exist or immediately downstream from the regulated process if no pretreatment exists. If other wastewaters are mixed with the regulated wastewater prior to pretreatment the User should measure the flows and concentrations necessary to allow use of the combined wastestream formula of § 403.6(e) in order to evaluate compliance with the Pretreatment Standards. Where an alternate concentration or mass limit has been calculated in accordance with § 403.6(e) this adjusted limit along with supporting data shall be submitted to the Control Authority;</P>
        <P>(vi) Sampling and analysis shall be performed in accordance with the techniques prescribed in 40 CFR part 136 and amendments thereto. Where 40 CFR part 136 does not contain sampling or analytical techniques for the pollutant in question, or where the Administrator determines that the part 136 sampling and analytical techniques are inappropriate for the pollutant in question, sampling and analysis shall be performed by using validated analytical methods or any other applicable sampling and analytical procedures, including procedures suggested by the POTW or other parties, approved by the Administrator;</P>
        <P>(vii) The Control Authority may allow the submission of a baseline report which utilizes only historical data so long as the data provides information sufficient to determine the need for industrial pretreatment measures;</P>
        <P>(viii) The baseline report shall indicate the time, date and place, of sampling, and methods of analysis, and shall certify that such sampling and analysis is representative of normal work cycles and expected pollutant Discharges to the POTW;</P>
        <P>(6) <E T="03">Certification.</E> A statement, reviewed by an authorized representative of the Industrial User (as defined in <PRTPAGE P="37"/>paragraph (k) of this section) and certified to by a qualified professional, indicating whether Pretreatment Standards are being met on a consistent basis, and, if not, whether additional operation and maintenance (O and M) and/or additional pretreatment is required for the Industrial User to meet the Pretreatment Standards and Requirements; and</P>
        <P>(7) <E T="03">Compliance schedule.</E> If additional pretreatment and/or O and M will be required to meet the Pretreatment Standards; the shortest schedule by which the Industrial User will provide such additional pretreatment and/or O and M. The completion date in this schedule shall not be later than the compliance date established for the applicable Pretreatment Standard.</P>
        <P>(i) Where the Industrial User's categorical Pretreatment Standard has been modified by a removal allowance (§ 403.7), the combined wastestream formula (§ 403.6(e)), and/or a Fundamentally Different Factors variance (§ 403.13) at the time the User submits the report required by paragraph (b) of this section, the information required by paragraphs (b)(6) and (7) of this section shall pertain to the modified limits.</P>
        <P>(ii) If the categorical Pretreatment Standard is modified by a removal allowance (§ 403.7), the combined wastestream formula (§ 403.6(e)), and/or a Fundamentally Different Factors variance (§ 403.13) after the User submits the report required by paragraph (b) of this section, any necessary amendments to the information requested by paragraphs (b)(6) and (7) of this section shall be submitted by the User to the Control Authority within 60 days after the modified limit is approved.</P>
        <P>(c) <E T="03">Compliance schedule for meeting categorical Pretreatment Standards.</E> The following conditions shall apply to the schedule required by paragraph (b)(7) of this section:</P>
        <P>(1) The schedule shall contain increments of progress in the form of dates for the commencement and completion of major events leading to the construction and operation of additional pretreatment required for the Industrial User to meet the applicable categorical Pretreatment Standards (e.g., hiring an engineer, completing preliminary plans, completing final plans, executing contract for major components, commencing construction, completing construction, etc.).</P>
        <P>(2) No increment referred to in paragraph (c)(1) of this section shall exceed 9 months.</P>
        <P>(3) Not later than 14 days following each date in the schedule and the final date for compliance, the Industrial User shall submit a progress report to the Control Authority including, at a minimum, whether or not it complied with the increment of progress to be met on such date and, if not, the date on which it expects to comply with this increment of progress, the reason for delay, and the steps being taken by the Industrial User to return the construction to the schedule established. In no event shall more than 9 months elapse between such progress reports to the Control Authority.</P>
        <P>(d) <E T="03">Report on compliance with categorical pretreatment standard deadline.</E> Within 90 days following the date for final compliance with applicable categorical Pretreatment Standards or in the case of a New Source following commencement of the introduction of wastewater into the POTW, any Industrial User subject to Pretreatment Standards and Requirements shall submit to the Control Authority a report containing the information described in paragraphs (b) (4)-(6) of this section. For Industrial Users subject to equivalent mass or concentration limits established by the Control Authority in accordance with the procedures in § 403.6(c), this report shall contain a reasonable measure of the User's long term production rate. For all other Industrial Users subject to categorical Pretreatment Standards expressed in terms of allowable pollutant discharge per unit of production (or other measure of operation), this report shall include the User's actual production during the appropriate sampling period.</P>
        <P>(e) <E T="03">Periodic reports on continued compliance.</E> (1) Any Industrial User subject to a categorical Pretreatment Standard, after the compliance date of such Pretreatment Standard, or, in the case of a New Source, after commencement of the discharge into the POTW, shall <PRTPAGE P="38"/>submit to the Control Authority during the months of June and December, unless required more frequently in the Pretreatment Standard or by the Control Authority or the Approval Authority, a report indicating the nature and concentration of pollutants in the effluent which are limited by such categorical Pretreatment Standards. In addition, this report shall include a record of measured or estimated average and maximum daily flows for the reporting period for the Discharge reported in paragraph (b)(4) of this section except that the Control Authority may require more detailed reporting of flows. At the discretion of the Control Authority and in consideraton of such factors as local high or low flow rates, holidays, budget cycles, etc., the Control Authority may agree to alter the months during which the above reports are to be submitted.</P>
        <P>(2) Where the Control Authority has imposed mass limitations on Industrial Users as provided for by § 403.6(d), the report required by paragraph (e)(1) of this section shall indicate the mass of pollutants regulated by Pretreatment Standards in the Discharge from the Industrial User.</P>
        <P>(3) For Industrial Users subject to equivalent mass or concentration limits established by the Control Authority in accordance with the procedures in § 403.6(c), the report required by paragraph (e)(1) shall contain a reasonable measure of the User's long term production rate. For all other Industrial Users subject to categorical Pretreatment Standards expressed only in terms of allowable pollutant discharge per unit of production (or other measure of operation), the report required by paragraph (e)(1) shall include the User's actual average production rate for the reporting period.</P>
        <P>(f) <E T="03">Notice of potential problems, including slug loading.</E> All categorical and non-categorical Industrial Users shall notify the POTW immediately of all discharges that could cause problems to the POTW, including any slug loadings, as defined by § 403.5(b), by the Industrial User.</P>
        <P>(g) <E T="03">Monitoring and analysis to demonstrate continued compliance.</E> (1) The reports required in paragraphs (b), (d), and (e) of this section shall contain the results of sampling and analaysis of the Discharge, including the flow and the nature and concentration, or production and mass where requested by the Control Authority, of pollutants contained therein which are limited by the applicable Pretreatment Standards. This sampling and analysis may be performed by the Control Authority in lieu of the Industrial User. Where the POTW performs the required sampling and analysis in lieu of the Industrial User, the User will not be required to submit the compliance certification required under §§ 403.12(b) (6) and 403.12(d). In addition, where the POTW itself collects all the information required for the report, including flow data, the Industrial User will not be required to submit the report.</P>
        <P>(2) If sampling performed by an Industrial User indicates a violation, the user shall notify the Control Authority within 24 hours of becoming aware of the violation. The User shall also repeat the sampling and analysis and submit the results of the repeat analysis to the Control Authority within 30 days after becoming aware of the violation, except the Industrial User is not required to resample if:</P>
        <P>(i) The Control Authority performs sampling at the Industrial User at a frequency of at least once per month, or</P>
        <P>(ii) The Control Authority performs sampling at the User between the time when the User performs its initial sampling and the time when the User receives the results of this sampling.</P>
        <P>(3) The reports required in paragraph (e) of this section shall be based upon data obtained through appropriate sampling and analysis performed during the period covered by the report, which data is representative of conditions occurring during the reporting period. The Control Authority shall require that frequency of monitoring necessary to assess and assure compliance by Industrial Users with applicable Pretreatment Standards and Requirements.</P>

        <P>(4) All analyses shall be performed in accordance with procedures established by the Administrator pursuant to section 304(h) of the Act and contained in 40 CFR part 136 and amendments thereto or with any other test procedures <PRTPAGE P="39"/>approved by the Administrator. (<E T="03">See,</E> §§ 136.4 and 136.5.) Sampling shall be performed in accordance with the techniques approved by the Administrator. Where 40 CFR part 136 does not include sampling or analytical techniques for the pollutants in question, or where the Administrator determines that the part 136 sampling and analytical techniques are inappropriate for the pollutant in question, sampling and analyses shall be performed using validated analytical methods or any other sampling and analytical procedures, including procedures suggested by the POTW or other parties, approved by the Administrator.</P>
        <P>(5) If an Industrial User subject to the reporting requirement in paragraph (e) of this section monitors any pollutant more frequently than required by the Control Authority, using the procedures prescribed in paragraph (g)(4) of this section, the results of this monitoring shall be included in the report.</P>
        <P>(h) <E T="03">Reporting requirements for Industrial Users not subject to categorical Pretreatment Standards.</E> The Control Authority shall require appropriate reporting from those Industrial Users with discharges that are not subject to categorical Pretreatment Standards. Significant Noncategorical Industrial Users shall submit to the Control Authority at least once every six months (on dates specified by the Control Authority) a description of the nature, concentration, and flow of the pollutants required to be reported by the Control Authority. These reports shall be based on sampling and analysis performed in the period covered by the report, and performed in accordance with the techniques described in 40 CFR part 136 and amendments thereto. Where 40 CFR part 136 does not contain sampling or analytical techniques for the pollutant in question, or where the Administrator determines that the part 136 sampling and analytical techniques are inappropriate for the pollutant in question, sampling and analysis shall be performed by using validated analytical methods or any other applicable sampling and analytical procedures, including procedures suggested by the POTW or other persons, approved by the Administrator. This sampling and analysis may be performed by the Control Authority in lieu of the significant noncategorical industrial user. Where the POTW itself collects all the information required for the report, the noncategorical significant industrial user will not be required to submit the report.</P>
        <P>(i) <E T="03">Annual POTW reports.</E> POTWs with approved Pretreatment Programs shall provide the Approval Authority with a report that briefly describes the POTW's program activities, including activities of all participating agencies, if more than one jurisdiction is involved in the local program. The report required by this section shall be submitted no later than one year after approval of the POTW's Pretreatment Program, and at least annually thereafter, and shall include, at a minimum, the following:</P>
        <P>(1) An updated list of the POTW's Industrial Users, including their names and addresses, or a list of deletions and additions keyed to a previously submitted list. The POTW shall provide a brief explanation of each deletion. This list shall identify which Industrial Users are subject to categorical pretreatment Standards and specify which Standards are applicable to each Industrial User. The list shall indicate which Industrial Users are subject to local standards that are more stringent than the categorical Pretreatment Standards. The POTW shall also list the Industrial Users that are subject only to local Requirements.</P>
        <P>(2) A summary of the status of Industrial User compliance over the reporting period;</P>
        <P>(3) A summary of compliance and enforcement activities (including inspections) conducted by the POTW during the reporting period;</P>
        <P>(4) A summary of changes to the POTW's pretreatment program that have not been previously reported to the Approval Authority; and</P>
        <P>(5) Any other relevant information requested by the Approval Authority.</P>

        <P>(j) Notification of changed discharge. All Industrial Users shall promptly notify the POTW in advance of any substantial change in the volume or character of pollutants in their discharge, including the listed or characteristic <PRTPAGE P="40"/>hazardous wastes for which the Industrial User has submitted initial notification under 40 CFR 403.12(p).</P>
        <P>(k) <E T="03">Compliance schedule for POTW's.</E> The following conditions and reporting requirements shall apply to the compliance schedule for development of an approvable POTW Pretreatment Program required by § 403.8.</P>
        <P>(1) The schedule shall contain increments of progress in the form of dates for the commencement and completion of major events leading to the development and implementation of a POTW Pretreatment Program (e.g., acquiring required authorities, developing funding mechanisms, acquiring equipment);</P>
        <P>(2) No increment referred to in paragraph (h)(1) of this section shall exceed nine months;</P>
        <P>(3) Not later than 14 days following each date in the schedule and the final date for compliance, the POTW shall submit a progress report to the Approval Authority including, as a minimum, whether or not it complied with the increment of progress to be met on such date and, if not, the date on which it expects to comply with this increment of progress, the reason for delay, and the steps taken by the POTW to return to the schedule established. In no event shall more than nine months elapse between such progress reports to the Approval Authority.</P>
        <P>(l) <E T="03">Signatory requirements for industrial user reports.</E> The reports required by paragraphs (b), (d), and (e) of this section shall include the certification statement as set forth in § 403.6(a)(2)(ii), and shall be signed as follows:</P>
        <P>(1) By a responsible corporate officer, if the Industrial User submitting the reports required by paragraphs (b), (d) and (e) of this section is a corporation. For the purpose of this paragraph, a responsible corporate officer means (i) a president, secretary, treasurer, or vice-president of the corporation in charge of a principal business function, or any other person who performs similar policy- or decision-making functions for the corporation, or (ii) the manager of one or more manufacturing, production, or operation facilities employing more than 250 persons or having gross annual sales or expenditures exceeding $25 million (in second-quarter 1980 dollars), if authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures.</P>
        <P>(2) By a general partner or proprietor if the Industrial User submitting the reports required by paragraphs (b), (d) and (e) of this section is a partnership or sole proprietorship respectively.</P>
        <P>(3) By a duly authorized representative of the individual designated in paragraph (l)(1) or (l)(2) of this section if:</P>
        <P>(i) The authorization is made in writing by the individual described in paragraph (l)(1) or (l)(2);</P>
        <P>(ii) The authorization specifies either an individual or a position having responsibility for the overall operation of the facility from which the Industrial Discharge originates, such as the position of plant manager, operator of a well, or well field superintendent, or a position of equivalent responsibility, or having overall responsibility for environmental matters for the company; and</P>
        <P>(iii) the written authorization is submitted to the Control Authority.</P>
        <P>(4) If an authorization under paragraph (l)(3) of this section is no longer accurate because a different individual or position has responsibility for the overall operation of the facility, or overall responsibility for environmental matters for the company, a new authorization satisfying the requirements of paragraph (l)(3) of this section must be submitted to the Control Authority prior to or together with any reports to be signed by an authorized representative.</P>
        <P>(m) <E T="03">Signatory requirements for POTW reports.</E> Reports submitted to the Approval Authority by the POTW in accordance with paragraph (h) of this section must be signed by a principal executive officer, ranking elected official or other duly authorized employee if such employee is responsible for overall operation of the POTW.</P>
        <P>(n) Provisions Governing Fraud and False Statements: The reports and other documents required to be submitted or maintained under this section shall be subject to:</P>

        <P>(1) The provisions of 18 U.S.C. section 1001 relating to fraud and false statements;<PRTPAGE P="41"/>
        </P>
        <P>(2) The provisions of sections 309(c)(4) of the Act, as amended, governing false statements, representation or certification; and</P>
        <P>(3) The provisions of section 309(c)(6) regarding responsible corporate officers.</P>
        <P>(o) <E T="03">Record-keeping requirements.</E> (1) Any Industrial User and POTW subject to the reporting requirements established in this section shall maintain records of all information resulting from any monitoring activities required by this section. Such records shall include for all samples:</P>
        <P>(i) The date, exact place, method, and time of sampling and the names of the person or persons taking the samples;</P>
        <P>(ii) The dates analyses were performed;</P>
        <P>(iii) Who performed the analyses;</P>
        <P>(iv) The analytical techniques/methods use; and</P>
        <P>(v) The results of such analyses.</P>
        <P>(2) Any Industrial User or POTW subject to the reporting requirements established in this section shall be required to retain for a minimum of 3 years any records of monitoring activities and results (whether or not such monitoring activities are required by this section) and shall make such records available for inspection and copying by the Director and the Regional Administrator (and POTW in the case of an Industrial User). This period of retention shall be extended during the course of any unresolved litigation regarding the Industrial User or POTW or when requested by the Director or the Regional Administrator.</P>
        <P>(3) Any POTW to which reports are submitted by an Industrial User pursuant to paragraphs (b), (d), (e), and (h) of this section shall retain such reports for a minimum of 3 years and shall make such reports available for inspection and copying by the Director and the Regional Administrator. This period of retention shall be extended during the course of any unresolved litigation regarding the discharge of pollutants by the Industrial User or the operation of the POTW Pretreatment Program or when requested by the Director or the Regional Administrator.</P>
        <P>(p)(1) The Industrial User shall notify the POTW, the EPA Regional Waste Management Division Director, and State hazardous waste authorities in writing of any discharge into the POTW of a substance, which, if otherwise disposed of, would be a hazardous waste under 40 CFR part 261. Such notification must include the name of the hazardous waste as set forth in 40 CFR part 261, the EPA hazardous waste number, and the type of discharge (continuous, batch, or other). If the Industrial User discharges more than 100 kilograms of such waste per calendar month to the POTW, the notification shall also contain the following information to the extent such information is known and readily available to the Industrial User: An identification of the hazardous constituents contained in the wastes, an estimation of the mass and concentration of such constituents in the wastestream discharged during that calendar month, and an estimation of the mass of constituents in the wastestream expected to be discharged during the following twelve months. All notifications must take place within 180 days of the effective date of this rule. Industrial users who commence discharging after the effective date of this rule shall provide the notification no later than 180 days after the discharge of the listed or characteristic hazardous waste. Any notification under this paragraph need be submitted only once for each hazardous waste discharged. However, notifications of changed discharges must be submitted under 40 CFR 403.12 (j). The notification requirement in this section does not apply to pollutants already reported under the self-monitoring requirements of 40 CFR 403.12 (b), (d), and (e).</P>
        <P>(2) Dischargers are exempt from the requirements of paragraph (p)(1) of this section during a calendar month in which they discharge no more than fifteen kilograms of hazardous wastes, unless the wastes are acute hazardous wastes as specified in 40 CFR 261.30(d) and 261.33(e). Discharge of more than fifteen kilograms of non-acute hazardous wastes in a calendar month, or of any quantity of acute hazardous wastes as specified in 40 CFR 261.30(d) and 261.33(e), requires a one-time notification.</P>

        <P>Subsequent months during which the Industrial User discharges more than <PRTPAGE P="42"/>such quantities of any hazardous waste do not require additional notification.</P>
        <P>(3) In the case of any new regulations under section 3001 of RCRA identifying additional characteristics of hazardous waste or listing any additional substance as a hazardous waste, the Industrial User must notify the POTW, the EPA Regional Waste Management Waste Division Director, and State hazardous waste authorities of the discharge of such substance within 90 days of the effective date of such regulations.</P>
        <P>(4) In the case of any notification made under paragraph (p) of this section, the Industrial User shall certify that it has a program in place to reduce the volume and toxicity of hazardous wastes generated to the degree it has determined to be economically practical.</P>
        <CITA>[46 FR 9439, Jan. 28, 1981, as amended at 49 FR 31225, Aug. 3, 1984; 51 FR 20429, June 4, 1986; 53 FR 40613, Oct. 17, 1988; 55 FR 30131, July 24, 1990; 58 FR 18017, Apr. 7, 1993; 60 FR 33932, June 29, 1995; 62 FR 38414, July 17, 1997]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 403.13</SECTNO>
        <SUBJECT>Variances from categorical pretreatment standards for fundamentally different factors.</SUBJECT>
        <P>(a) <E T="03">Definition.</E> The term <E T="03">Requester</E> means an Industrial User or a POTW or other interested person seeking a variance from the limits specified in a categorical Pretreatment Standard.</P>
        <P>(b) <E T="03">Purpose and scope.</E> In establishing categorical Pretreatment Standards for existing sources, the EPA will take into account all the information it can collect, develop and solicit regarding the factors relevant to pretreatment standards under section 307(b). In some cases, information which may affect these Pretreatment Standards will not be available or, for other reasons, will not be considered during their development. As a result, it may be necessary on a case-by-case basis to adjust the limits in categorical Pretreatment Standards, making them either more or less stringent, as they apply to a certain Industrial User within an industrial category or subcategory. This will only be done if data specific to that Industrial User indicates it presents factors fundamentally different from those considered by EPA in developing the limit at issue. Any interested person believing that factors relating to an Industrial User are fundamentally different from the factors considered during development of a categorical Pretreatment Standard applicable to that User and further, that the existence of those factors justifies a different discharge limit than specified in the applicable categorical Pretreatment Standard, may request a fundamentally different factors variance under this section or such a variance request may be initiated by the EPA.</P>
        <P>(c) <E T="03">Criteria—</E>(1) <E T="03">General criteria.</E> A request for a variance based upon fundamentally different factors shall be approved only if:</P>
        <P>(i) There is an applicable categorical Pretreatment Standard which specifically controls the pollutant for which alternative limits have been requested; and</P>
        <P>(ii) Factors relating to the discharge controlled by the categorical Pretreatment Standard are fundamentally different from the factors considered by EPA in establishing the Standards; and</P>
        <P>(iii) The request for a variance is made in accordance with the procedural requirements in paragraphs (g) and (h) of this section.</P>
        <P>(2) <E T="03">Criteria applicable to less stringent limits.</E> A variance request for the establishment of limits less stringent than required by the Standard shall be approved only if:</P>
        <P>(i) The alternative limit requested is no less stringent than justified by the fundamental difference;</P>
        <P>(ii) The alternative limit will not result in a violation of prohibitive discharge standards prescribed by or established under § 403.5;</P>
        <P>(iii) The alternative limit will not result in a non-water quality environmental impact (including energy requirements) fundamentally more adverse than the impact considered during development of the Pretreatment Standards; and</P>
        <P>(iv) Compliance with the Standards (either by using the technologies upon which the Standards are based or by using other control alternatives) would result in either:</P>

        <P>(A) A removal cost (adjusted for inflation) wholly out of proportion to the <PRTPAGE P="43"/>removal cost considered during development of the Standards; or</P>
        <P>(B) A non-water quality environmental impact (including energy requirements) fundamentally more adverse than the impact considered during development of the Standards.</P>
        <P>(3) <E T="03">Criteria applicable to more stringent limits.</E> A variance request for the establishment of limits more stringent than required by the Standards shall be approved only if:</P>
        <P>(i) The alternative limit request is no more stringent than justified by the fundamental difference; and</P>
        <P>(ii) Compliance with the alternative limit would not result in either:</P>
        <P>(A) A removal cost (adjusted for inflation) wholly out of proportion to the removal cost considered during development of the Standards; or</P>
        <P>(B) A non-water quality environmental impact (including energy requirements) fundamentally more adverse than the impact considered during development of the Standards.</P>
        <P>(d) <E T="03">Factors considered fundamentally different.</E> Factors which may be considered fundamentally different are:</P>
        <P>(1) The nature or quality of pollutants contained in the raw waste load of the User's process wastewater:</P>
        <P>(2) The volume of the User's process wastewater and effluent discharged;</P>
        <P>(3) Non-water quality environmental impact of control and treatment of the User's raw waste load;</P>
        <P>(4) Energy requirements of the application of control and treatment technology;</P>
        <P>(5) Age, size, land availability, and configuration as they relate to the User's equipment or facilities; processes employed; process changes; and engineering aspects of the application of control technology;</P>
        <P>(6) Cost of compliance with required control technology.</P>
        <P>(e) <E T="03">Factors which will not be considered fundamentally different.</E> A variance request or portion of such a request under this section may not be granted on any of the following grounds:</P>
        <P>(1) The feasibility of installing the required waste treatment equipment within the time the Act allows;</P>
        <P>(2) The assertion that the Standards cannot be achieved with the appropriate waste treatment facilities installed, if such assertion is not based on factors listed in paragraph (d) of this section;</P>
        <P>(3) The User's ability to pay for the required waste treatment; or</P>
        <P>(4) The impact of a Discharge on the quality of the POTW's receiving waters.</P>
        <P>(f) <E T="03">State or local law.</E> Nothing in this section shall be construed to impair the right of any state or locality under section 510 of the Act to impose more stringent limitations than required by Federal law.</P>
        <P>(g) <E T="03">Application deadline.</E> (1) Requests for a variance and supporting information must be submitted in writing to the Director or to the Administrator (or his delegate), as appropriate.</P>

        <P>(2) In order to be considered, a request for a variance must be submitted no later than 180 days after the date on which a categorical Pretreatment Standard is published in the <E T="04">Federal Register</E>.</P>
        <P>(3) Where the User has requested a catergorical determination pursuant to § 403.6(a), the User may elect to await the results of the category determination before submitting a variance request under this section. Where the User so elects, he or she must submit the variance request within 30 days after a final decision has been made on the categorical determination pursuant to § 403.6(a)(4).</P>
        <P>(h) <E T="03">Contents submission.</E> Written submissions for variance requests, whether made to the Administrator (or his delegate) or the Director, must include:</P>
        <P>(1) The name and address of the person making the request;</P>
        <P>(2) Identification of the interest of the Requester which is affected by the categorical Pretreatment Standard for which the variance is requested;</P>
        <P>(3) Identification of the POTW currently receiving the waste from the Industrial User for which alternative discharge limits are requested;</P>
        <P>(4) Identification of the categorical Pretreatment Standards which are applicable to the Industrial User;</P>

        <P>(5) A list of each pollutant or pollutant parameter for which an alternative discharge limit is sought;<PRTPAGE P="44"/>
        </P>
        <P>(6) The alternative discharge limits proposed by the Requester for each pollutant or pollutant parameter identified in paragraph (h)(5) of this section;</P>
        <P>(7) A description of the Industrial User's existing water pollution control facilities;</P>
        <P>(8) A schematic flow representation of the Industrial User's water system including water supply, process wastewater systems, and points of Discharge; and</P>
        <P>(9) A Statement of facts clearly establishing why the variance request should be approved, including detailed support data, documentation, and evidence necessary to fully evaluate the merits of the request, e.g., technical and economic data collected by the EPA and used in developing each pollutant discharge limit in the Pretreatment Standard.</P>
        <P>(i) <E T="03">Deficient requests.</E> The Administrator (or his delegate) or the Director will only act on written requests for variances that contain all of the information required. Persons who have made incomplete submissions will be notified by the Administrator (or his delegate) or the Director that their requests are deficient and unless the time period is extended, will be given up to thirty days to remedy the deficiency. If the deficiency is not corrected within the time period allowed by the Administrator (or his delegate) or the Director, the request for a variance shall be denied.</P>
        <P>(j) <E T="03">Public notice.</E> Upon receipt of a complete request, the Administrator (or his delegate) or the Director will provide notice of receipt, opportunity to review the submission, and opportunity to comment.</P>
        <P>(1) The public notice shall be circulated in a manner designed to inform interested and potentially interested persons of the request. Procedures for the circulation of public notice shall include mailing notices to:</P>
        <P>(i) The POTW into which the Industrial User requesting the variance discharges;</P>
        <P>(ii) Adjoining States whose waters may be affected; and</P>
        <P>(iii) Designated 208 planning agencies, Federal and State fish, shellfish and wildlife resource agencies; and to any other person or group who has requested individual notice, including those on appropriate mailing lists.</P>
        <P>(2) The public notice shall provide for a period not less than 30 days following the date of the public notice during which time interested persons may review the request and submit their written views on the request.</P>
        <P>(3) Following the comment period, the Administrator (or his delegate) or the Director will make a determination on the request taking into consideration any comments received. Notice of this final decision shall be provided to the requester (and the Industrial User for which the variance is requested if different), the POTW into which the Industrial User discharges and all persons who submitted comments on the request.</P>
        <P>(k) <E T="03">Review of requests by state.</E> (1) Where the Director finds that fundamentally different factors do not exist, he may deny the request and notify the requester (and Industrial User where they are not the same) and the POTW of the denial.</P>
        <P>(2) Where the Director finds that fundamentally different factors do exist, he shall forward the request, with a recommendation that the request be approved, to the Administrator (or his delegate).</P>
        <P>(l) <E T="03">Review of requests by EPA.</E> (1) Where the Administrator (or his delegate) finds that fundamentally different factors do not exist, he shall deny the request for a variance and send a copy of his determination to the Director, to the POTW, and to the requester (and to the Industrial User, where they are not the same).</P>
        <P>(2) Where the Administrator (or his delegate) finds that fundamentally different factors do exist, and that a partial or full variance is justified, he will approve the variance. In approving the variance, the Administrator (or his delegate) will:</P>
        <P>(i) Prepare recommended alternative discharge limits for the Industrial User either more or less stringent than those prescribed by the applicable categorical Pretreatment Standard to the extent warranted by the demonstrated fundamentally different factors;</P>

        <P>(ii) Provide the following information in his written determination:<PRTPAGE P="45"/>
        </P>
        <P>(A) The recommended alternative discharge limits for the Industrial User concerned;</P>
        <P>(B) The rationale for the adjustment of the Pretreatment Standard (including the reasons for recommending that the variance be granted) and an explanation of how the recommended alternative discharge limits were derived;</P>
        <P>(C) The supporting evidence submitted to the Administrator (or his delegate); and</P>
        <P>(D) Other information considered by the Administrator (or his delegate) in developing the recommended alternative discharge limits;</P>
        <P>(iii) Notify the Director and the POTW of his or her determination; and</P>
        <P>(iv) Send the information described in paragraphs (l)(2) (i) and (ii) of this section to the Requestor (and to the Industrial User where they are not the same).</P>
        <P>(m) <E T="03">Request for hearing.</E> (1) Within 30 days following the date of receipt of the notice of the decision of the Administrator's delegate on a variance request, the requester or any other interested person may submit a petition to the Regional Administrator for a hearing to reconsider or contest the decision. If such a request is submitted by a person other than the Industrial User the person shall simultaneously serve a copy of the request on the Industrial User.</P>
        <P>(2) If the Regional Administrator declines to hold a hearing and the Regional Administrator affirms the findings of the Administrator's delegate the requester may submit a petition for a hearing to the Environmental Appeals Board (which is described in § 1.25 of this title) within 30 days of the Regional Administrator's decision.</P>
        <CITA>[46 FR 9439, Jan. 28, 1981, as amended at 49 FR 5132, Feb. 10, 1984; 50 FR 38811, Sept. 25, 1985; 51 FR 16030, Apr. 30, 1986; 54 FR 258, Jan. 4, 1989; 57 FR 5347, Feb. 13, 1992; 58 FR 18017, Apr. 7, 1993; 60 FR 33932, June 29, 1995]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 403.14</SECTNO>
        <SUBJECT>Confidentiality.</SUBJECT>
        <P>(a) <E T="03">EPA authorities.</E> In accordance with 40 CFR part 2, any information submitted to EPA pursuant to these regulations may be claimed as confidential by the submitter. Any such claim must be asserted at the time of submission in the manner prescribed on the application form or instructions, or, in the case of other submissions, by stamping the words “confidential business information” on each page containing such information. If no claim is made at the time of submission, EPA may make the information available to the public without further notice. If a claim is asserted, the information will be treated in accordance with the procedures in 40 CFR part 2 (Public Information).</P>
        <P>(b) <E T="03">Effluent data.</E> Information and data provided to the Control Authority pursuant to this part which is effluent data shall be available to the public without restriction.</P>
        <P>(c) <E T="03">State or POTW.</E> All other information which is submitted to the State or POTW shall be available to the public at least to the extent provided by 40 CFR 2.302.</P>
      </SECTION>
      <SECTION>
        <SECTNO>§ 403.15</SECTNO>
        <SUBJECT>Net/Gross calculation.</SUBJECT>
        <P>Categorical Pretreatment Standards may be adjusted to reflect the presence of pollutants in the Industrial User's intake water in accordance with this section.</P>
        <P>(a) <E T="03">Application.</E> Any Industrial User wishing to obtain credit for intake pollutants must make application to the Control Authority. Upon request of the Industrial User, the applicable Standard will be calculated on a “net” basis (i.e., adjusted to reflect credit for pollutants in the intake water) if the requirements of paragraphs (b) and (c) of this section are met.</P>
        <P>(b) <E T="03">Criteria.</E> (1) The Industrial User must demonstrate that the control system it proposes or uses to meet applicable categorical Pretreatment Standards would, if properly installed and operated, meet the Standards in the absence of pollutants in the intake waters.</P>

        <P>(2) Credit for generic pollutants such as biochemical oxygen demand (BOD), total suspended solids (TSS), and oil and grease should not be granted unless the Industrial User demonstrates that the constituents of the generic measure in the User's effluent are substantially similar to the constituents of the generic measure in the intake water or unless appropirate additional <PRTPAGE P="46"/>limits are placed on process water pollutants either at the outfall or elsewhere.</P>
        <P>(3) Credit shall be granted only to the extent necessary to meet the applicable categorical Pretreatment Standard(s), up to a maximum value equal to the influent value. Additional monitoring may be necessary to determine eligibility for credits and compliance with Standard(s) adjusted under this section.</P>
        <P>(4) Credit shall be granted only if the User demonstrates that the intake water is drawn from the same body of water as that into which the POTW discharges. The Control Authority may waive this requirement if it finds that no environmental degradation will result.</P>
        <P>(c) The applicable categorical pretreatment standards contained in 40 CFR subchapter N specifically provide that they shall be applied on a net basis.</P>
        <CITA>[53 FR 40614, Oct. 17, 1988, as amended at 58 FR 18017, Apr. 7, 1993]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 403.16</SECTNO>
        <SUBJECT>Upset provision.</SUBJECT>
        <P>(a) <E T="03">Definition.</E> For the purposes of this section, <E T="03">Upset</E> means an exceptional incident in which there is unintentional and temporary noncompliance with categorical Pretreatment Standards because of factors beyond the reasonable control of the Industrial User. An Upset does not include noncompliance to the extent caused by operational error, improperly designed treatment facilities, inadequate treatment facilities, lack of preventive maintenance, or careless or improper operation.</P>
        <P>(b) <E T="03">Effect of an upset.</E> An Upset shall constitute an affirmative defense to an action brought for noncompliance with categorical Pretreatment Standards if the requirements of paragraph (c) are met.</P>
        <P>(c) <E T="03">Conditions necessary for a demonstration of upset.</E> An Industrial User who wishes to establish the affirmative defense of Upset shall demonstrate, through properly signed, contemporaneous operating logs, or other relevant evidence that:</P>
        <P>(1) An Upset occurred and the Industrial User can identify the cause(s) of the Upset;</P>
        <P>(2) The facility was at the time being operated in a prudent and workman-like manner and in compliance with applicable operation and maintenance procedures;</P>
        <P>(3) The Industrial User has submitted the following information to the POTW and Control Authority within 24 hours of becoming aware of the Upset (if this information is provided orally, a written submission must be provided within five days):</P>
        <P>(i) A description of the Indirect Discharge and cause of noncompliance;</P>
        <P>(ii) The period of noncompliance, including exact dates and times or, if not corrected, the anticipated time the noncompliance is expected to continue;</P>
        <P>(iii) Steps being taken and/or planned to reduce, eliminate and prevent recurrence of the noncompliance.</P>
        <P>(d) <E T="03">Burden of proof.</E> In any enforcement proceeding the Industrial User seeking to establish the occurrence of an Upset shall have the burden of proof.</P>
        <P>(e) <E T="03">Reviewability of agency consideration of claims of upset.</E> In the usual exercise of prosecutorial discretion, Agency enforcement personnel should review any claims that non-compliance was caused by an Upset. No determinations made in the course of the review constitute final Agency action subject to judicial review. Industrial Users will have the opportunity for a judicial determination on any claim of Upset only in an enforcement action brought for noncompliance with categorical Pretreatment Standards.</P>
        <P>(f) <E T="03">User responsibility in case of upset.</E> The Industrial User shall control production or all Discharges to the extent necessary to maintain compliance with categorical Pretreatment Standards upon reduction, loss, or failure of its treatment facility until the facility is restored or an alternative method of treatment is provided. This requirement applies in the situation where, among other things, the primary source of power of the treatment facility is reduced, lost or fails.</P>
        <CITA>[46 FR 9439, Jan. 28, 1981, as amended at 53 FR 40615, Oct. 17, 1988]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 403.17</SECTNO>
        <SUBJECT>Bypass.</SUBJECT>
        <P>(a) <E T="03">Definitions.</E>  (1) <E T="03">Bypass</E> means the intentional diversion of wastestreams <PRTPAGE P="47"/>from any portion of an Industrial User's treatment facility.</P>
        <P>(2) <E T="03">Severe property damage</E> means substantial physical damage to property, damage to the treatment facilities which causes them to become inoperable, or substantial and permanent loss of natural resources which can reasonably be expected to occur in the absence of a bypass. Severe property damage does not mean economic loss caused by delays in production.</P>
        <P>(b) <E T="03">Bypass not violating applicable Pretreatment Standards or Requirements.</E>  An Industrial User may allow any bypass to occur which does not cause Pretreatment Standards or Requirements to be violated, but only if it also is for essential maintenance to assure efficient operation. These bypasses are not subject to the provision of paragraphs (c) and (d) of this section.</P>
        <P>(c) <E T="03">Notice.</E>  (1) If an Industrial User knows in advance of the need for a bypass, it shall submit prior notice to the Control Authority, if possible at least ten days before the date of the bypass.</P>
        <P>(2) An Industrial User shall submit oral notice of an unanticipated bypass that exceeds applicable Pretreatment Standards to the Control Authority within 24 hours from the time the Industrial User becomes aware of the bypass. A written submission shall also be provided within 5 days of the time the Industrial User becomes aware of the bypass. The written submission shall contain a description of the bypass and its cause; the duration of the bypass, including exact dates and times, and, if the bypass has not been corrected, the anticipated time it is expected to continue; and steps taken or planned to reduce, eliminate, and prevent reoccurrence of the bypass. The Control Authority may waive the written report on a case-by-case basis if the oral report has been received within 24 hours.</P>
        <P>(d) <E T="03">Prohibition of bypass.</E>  (1) Bypass is prohibited, and the Control Authority may take enforcement action against an Industrial User for a bypass, unless;</P>
        <P>(i) Bypass was unavoidable to prevent loss of life, personal injury, or severe property damage;</P>
        <P>(ii) There were no feasible alternatives to the bypass, such as the use of auxiliary treatment facilities, retention of untreated wastes, or maintenance during normal periods of equipment downtime. This condition is not satisfied if adequate back-up equipment should have been installed in the exercise of reasonable engineering judgment to prevent a bypass which occurred during normal periods of equipment downtime or preventative maintenance; and</P>
        <P>(iii) The Industrial User submitted notices as required under paragraph (c) of this section.</P>
        <P>(2) The Control Authority may approve an anticipated bypass, after considering its adverse effects, if the Control Authority determines that it will meet the three conditions listed in paragraph (d)(1) of this section.</P>
        <CITA>[53 FR 40615, Oct. 17, 1988, as amended at 58 FR 18017, Apr. 7, 1993]</CITA>
      </SECTION>
      <SECTION>
        <SECTNO>§ 403.18</SECTNO>
        <SUBJECT>Modification of POTW pretreatment programs.</SUBJECT>
        <P>(a) <E T="03">General.</E> Either the Approval Authority or a POTW with an approved POTW Pretreatment Program may initiate program modification at any time to reflect changing conditions at the POTW. Program modification is necessary whenever there is a significant change in the operation of a POTW Pretreatment Program that differs from the information in the POTW's submission, as approved under § 403.11.</P>
        <P>(b) <E T="03">Substantial modifications defined.</E> Substantial modifications include:</P>
        <P>(1) Modifications that relax POTW legal authorities (as described in § 403.8(f)(1)), except for modifications that directly reflect a revision to this Part 403 or to 40 CFR chapter I, subchapter N, and are reported pursuant to paragraph (d) of this section;</P>

        <P>(2) Modifications that relax local limits, except for the modifications to local limits for pH and reallocations of the Maximum Allowable Industrial Loading of a pollutant that do not increase the total industrial loadings for the pollutant, which are reported pursuant to paragraph (d) of this section. Maximum Allowable Industrial Loading means the total mass of a pollutant that all Industrial Users of a POTW (or <PRTPAGE P="48"/>a subgroup of Industrial Users identified by the POTW) may discharge pursuant to limits developed under § 403.5(c);</P>
        <P>(3) Changes to the POTW's control mechanism, as described in § 403.8(f)(1)(iii);</P>
        <P>(4) A decrease in the frequency of self-monitoring or reporting required of industrial users;</P>
        <P>(5) A decrease in the frequency of industrial user inspections or sampling by the POTW;</P>
        <P>(6) Changes to the POTW's confidentiality procedures; and</P>
        <P>(7) Other modifications designated as substantial modifications by the Approval Authority on the basis that the modification could have a significant impact on the operation of the POTW's Pretreatment Program; could result in an increase in pollutant loadings at the POTW; or could result in less stringent requirements being imposed on Industrial Users of the POTW.</P>
        <P>(c) <E T="03">Approval procedures for substantial modifications.</E> (1) The POTW shall submit to the Approval Authority a statement of the basis for the desired program modification, a modified program description (see § 403.9(b)), or such other documents the Approval Authority determines to be necessary under the circumstances.</P>
        <P>(2) The Approval Authority shall approve or disapprove the modification based on the requirements of § 403.8(f) and using the procedures in § 403.11(b) through (f), except as provided in paragraphs (c) (3) and (4) of this section. The modification shall become effective upon approval by the Approval Authority.</P>
        <P>(3) The Approval Authority need not publish a notice of decision under § 403.11(e) provided: The notice of request for approval under § 403.11(b)(1) states that the request will be approved if no comments are received by a date specified in the notice; no substantive comments are received; and the request is approved without change.</P>
        <P>(4) Notices required by § 403.11 may be performed by the POTW provided that the Approval Authority finds that the POTW notice otherwise satisfies the requirements of § 403.11.</P>
        <P>(d) <E T="03">Approval procedures for non-substantial modifications.</E> (1) The POTW shall notify the Approval Authority of any non-substantial modification at least 45 days prior to implementation by the POTW, in a statement similar to that provided for in paragraph (c)(1) of this section.</P>
        <P>(2) Within 45 days after the submission of the POTW's statement, the Approval Authority shall notify the POTW of its decision to approve or disapprove the non-substantial modification.</P>
        <P>(3) If the Approval Authority does not notify the POTW within 45 days of its decision to approve or deny the modification, or to treat the modification as substantial under paragraph (b)(7) of this section, the POTW may implement the modification.</P>
        <P>(e) <E T="03">Incorporation in permit.</E> All modifications shall be incorporated into the POTW's NPDES permit upon approval. The permit will be modified to incorporate the approved modification in accordance with 40 CFR 122.63(g).</P>
        <CITA>[62 FR 38414, July 17, 1997]</CITA>
      </SECTION>
      <APPENDIX>
        <RESERVED>Appendix F[Reserved]</RESERVED>
      </APPENDIX>
      <APPENDIX>
        <EAR>Pt. 403, App. A</EAR>
        <HD SOURCE="HED">Appendix A to Part 403—Program Guidance Memorandum</HD>
        <HD SOURCE="HD3">U.S. Environmental Protection Agency</HD>
        <HD SOURCE="HED">December 16, 1975.</HD>
        <HD SOURCE="HD2">Program Guidance Memorandum—61</HD>
        <FP SOURCE="FP-2">Subject: Grants for Treatment and Control of Combined Sewer Overflows and Stormwater Discharges.</FP>
        <FP SOURCE="FP-2">From: John T. Rhett, Deputy Assistant Administrator for Water Program Operations (WH-546).</FP>
        <FP SOURCE="FP-2">To: Regional Administrators, Regions I-X.</FP>
        
        <P>This memorandum summarizes the Agency's policy on the use of construction grants for treatment and control of combined sewer overflows and stormwater discharges during wet-weather conditions. The purpose is to assure that projects are funded only when careful planning has demonstrated they are cost-effective.</P>
        <HD SOURCE="HD1">I. Combined Sewer Overflows</HD>
        <HD SOURCE="HD2">A. Background</HD>

        <P>The costs and benefits of control of various portions of pollution due to combined sewer overflows and by-passes vary greatly with the characteristics of the sewer and treatment system, the duration, intensity, frequency and areal extent of precipitation, the <PRTPAGE P="49"/>type and extent of development in the service area, and the characteristics, uses and water quality standards of the receiving waters. Decisions on grants for control of combined sewer overflows, therefore, must be made on a case-by-case basis after detailed planning at the local level.</P>
        <P>Where detailed planning has been completed, treatment or control of pollution from wet-weather overflows and bypasses may be given priority for construction grant funds only after provision has been made for secondary treatment of dry-weather flows in the area. The detailed planning requirements and criteria for project approval follow.</P>
        <HD SOURCE="HD2">B. Planning Requirements</HD>
        <P>Construction grants may be approved for control of pollution from combined sewer overflows only if planning for the project was thoroughly analyzed for the 20 year planning period:</P>
        <P>1. Alternative control techniques which might be utilized to attain various levels of pollution control (related to alternative beneficial uses, if appropriate), including at least initial consideration of all the alternatives described in the section on combined sewer and stormwater control in “Alternative Waste Management Techniques and Best Practicable Waste Treatment” (Section C of Chapter III of the information proposed for comment in March 1974).</P>
        <P>2. The costs of achieving the various levels of pollution control by each of the techniques appearing to be the most feasible and cost-effective after the preliminary analysis.</P>
        <P>3. The benefits to the receiving waters of a range of levels of pollution control during wet-weather conditions. This analysis will normally be conducted as part of State water quality management planning, 208 areawide management planning, or other State, regional or local planning effort.</P>
        <P>4. The costs and benefits of addition of advanced waste treatment processes to dry-weather flows in the area.</P>
        <HD SOURCE="HD2">C. Criteria for Project Approval</HD>
        <P>The final alternative selected shall meet the following criteria:</P>
        <P>1. The analysis required above has demonstrated that the level of pollution control provided will be necessary to protect a beneficial use of the receiving water even after technology based standards required by Section 301 of Pub. L. 92-500 are achieved by industrial point sources and at least secondary treatment is achieved for dry-weather municipal flows in the area.</P>
        <P>2. Provision has already been made for funding of secondary treatment of dry-weather flows in the area.</P>
        <P>3. The pollution control technique proposed for combined sewer overflow is a more cost-effective means of protecting the beneficial use of the receiving waters than other combined sewer pollution control techniques and the addition of treatment higher than secondary treatment for dry-weather municipal flows in the area.</P>
        <P>4. The marginal costs are not substantial compared to marginal benefits.</P>
        <P>Marginal costs and benefits for each alternative may be displayed graphically to assist with determining a project's acceptability under this criterion. Dollar costs should be compared with quantified pollution reduction and water quality improvements. A descriptive narrative should also be included analyzing monetary, social and environmental costs compared to benefits, particularly the significance of the beneficial uses to be protected by the project.</P>
        <HD SOURCE="HD1">II. Stormwater Discharges</HD>
        <P>Approaches for reducing pollution from separate stormwater discharges are now in the early stages of development and evaluation. We anticipate, however, that in many cases the benefits obtained by construction of treatment works for this purpose will be small compared with the costs, and other techniques of control and prevention will be more cost-effective. The policy of the Agency is, therefore, that construction grants shall not be used for construction of treatment works to control pollution from separate discharges of stormwater except under unusual conditions where the project clearly has been demonstrated to meet the planning requirements and criteria described above for combined sewer overflows.</P>
        <HD SOURCE="HD1">III. Multi-purpose Projects</HD>
        <P>Projects with multiple purposes, such as flood control and recreation in addition to pollution control, may be eligible for an amount not to exceed the cost of the most cost-effective single purpose pollution abatement system. Normally the Separable Costs-Remaining Benefits (SCRB) method should be used to allocate costs between pollution control and other purposes, although in unusual cases another method may be appropriate. For such cost allocation, the cost of the least cost pollution abatement alternative may be used as a substitute measure of the benefits for that purpose. The method is described in “Proposed Practices for Economic Analysis of River Basin Projects,” GPO, Washington, D.C., 1958, and “Efficiency in Government through Systems Analysis,” by Roland N. McKean, John Wiley &amp; Sons, Inc., 1958.</P>

        <P>Enlargement of or otherwise adding to combined sewer conveyance systems is one means of reducing or eliminating flooding caused by wet-weather conditions. These additions may be designed so as to produce some benefits in terms of reduced discharge of pollutants to surrounding waterways. The <PRTPAGE P="50"/>pollution control benefits of such flood control measures, however, are likely to be small compared with the costs, and the measures therefore would normally be ineligible for funding under the construction grants program.</P>
        <P>All multi-purpose projects where less than 100% of the costs are eligible for construction grants under this policy shall contain a special grant condition precluding EPA funding of non-pollution control elements. This condition should, as a minimum, contain a provision similar to the following:</P>
        <FP>“The grantee explicitly acknowledges and agrees that costs are allowable only to the extent they are incurred for the water pollution control elements of this project.”</FP>
        <P>Additional special conditions should be included as appropriate to assure that the grantee clearly understands which elements of the project are eligible for construction grants under Pub. L. 92-500.</P>
      </APPENDIX>
      <APPENDIX>
        <RESERVED>Appendixes B-C to Part 403[Reserved]</RESERVED>
      </APPENDIX>
      <APPENDIX>
        <EAR>Pt. 403, App. B-C</EAR>
        <HD SOURCE="HED">Appendix D to Part 403—Selected Industrial Subcategories Considered Dilute for Purposes of the Combined Wastestream Formula</HD>
        <P>The following industrial subcategories are considered to have dilute wastestreams for purposes of the combined wastestream formula. They either were or could have been excluded from categorical pretreatment standards pursuant to paragraph 8 of the Natural Resources Defense Council, Inc., et al. v. Costle Consent Decree for one or more of the following four reasons: (1) The pollutants of concern are not detectable in the effluent from the industrial user (paragraph 8(a)(iii)); (2) the pollutants of concern are present only in trace amounts and are neither causing nor likely to cause toxic effects (paragraph 8(a)(iii)); (3) the pollutants of concern are present in amounts too small to be effectively reduced by technologies known to the Administrator (paragraph 8(a)(iii)); or (4) the wastestream contains only pollutants which are compatible with the POTW (paragraph 8(b)(i)). In some instances, different rationales were given for exclusion under paragraph 8. However, EPA has reviewed these subcategories and has determined that exclusion could have occurred due to one of the four reasons listed above.</P>
        <P>This list is complete as of October 9, 1986. It will be updated periodically for the convenience of the reader.</P>
        <FP SOURCE="FP-2">
          <E T="03">Auto and Other Laundries</E> (40 CFR part 444)</FP>
        <FP SOURCE="FP1-2">Carpet and Upholstery Cleaning</FP>
        <FP SOURCE="FP1-2">Coin-Operated Laundries and Dry Cleaning</FP>
        <FP SOURCE="FP1-2">Diaper Services</FP>
        <FP SOURCE="FP1-2">Dry Cleaning Plants except Rug Cleaning</FP>
        <FP SOURCE="FP1-2">Industrial Laundries</FP>
        <FP SOURCE="FP1-2">Laundry and Garment Services, Not Elsewhere Classified</FP>
        <FP SOURCE="FP1-2">Linen Supply</FP>
        <FP SOURCE="FP1-2">Power Laundries, Family and Commercial</FP>
        <FP SOURCE="FP-2">
          <E T="03">Electrical and Electronic Components \1\</E>
          <FTREF/>
          <E T="01">(40 CFR part 469)</E>
        </FP>
        <FTNT>
          <P>
            <SU>1</SU> The Paragraph 8 exemption for the manufacture of products in the Electrical and Electronic Components Category is for operations not covered by Electroplating/Metal Finishing pretreatment regulations (40 CFR parts 413/433).</P>
        </FTNT>
        <FP SOURCE="FP1-2">Capacitors (Fluid Fill)</FP>
        <FP SOURCE="FP1-2">Carbon and Graphite Products</FP>
        <FP SOURCE="FP1-2">Dry Transformers</FP>
        <FP SOURCE="FP1-2">Ferrite Electronic Devices</FP>
        <FP SOURCE="FP1-2">Fixed Capacitors</FP>
        <FP SOURCE="FP1-2">Fluorescent Lamps</FP>
        <FP SOURCE="FP1-2">Fuel Cells</FP>
        <FP SOURCE="FP1-2">Incandescent Lamps</FP>
        <FP SOURCE="FP1-2">Magnetic Coatings</FP>
        <FP SOURCE="FP1-2">Mica Paper Dielectric</FP>
        <FP SOURCE="FP1-2">Motors, Generators, Alternators</FP>
        <FP SOURCE="FP1-2">Receiving and Transmitting Tubes</FP>
        <FP SOURCE="FP1-2">Resistance Heaters</FP>
        <FP SOURCE="FP1-2">Resistors</FP>
        <FP SOURCE="FP1-2">Swithchgear</FP>
        <FP SOURCE="FP1-2">Transformer (Fluid Fill)</FP>
        <FP SOURCE="FP-2">
          <E T="03">Metal Molding and Casting</E> (40 CFR part 464)</FP>
        <FP SOURCE="FP1-2">Nickel Casting</FP>
        <FP SOURCE="FP1-2">Tin Casting</FP>
        <FP SOURCE="FP1-2">Titanium Casting</FP>
        <FP SOURCE="FP-2">
          <E T="03">Gum and Wood Chemicals</E> (40 CFR part 454)</FP>
        <FP SOURCE="FP1-2">Char and Charcoal Briquets</FP>
        <FP SOURCE="FP-2">
          <E T="03">Inorganic Chemicals Manufacturing</E> (40 CFR part 415)</FP>
        <FP SOURCE="FP1-2">Ammonium Chloride</FP>
        <FP SOURCE="FP1-2">Ammonium Hydroxide</FP>
        <FP SOURCE="FP1-2">Barium Carbonate</FP>
        <FP SOURCE="FP1-2">Calcium Carbonate</FP>
        <FP SOURCE="FP1-2">Carbon Dioxide</FP>
        <FP SOURCE="FP1-2">Carbon Monoxide and Byproduct Hydrogen</FP>
        <FP SOURCE="FP1-2">Hydrochloric Acid</FP>
        <FP SOURCE="FP1-2">Hydrogen Peroxide (Organic Process)</FP>
        <FP SOURCE="FP1-2">Nitric Acid</FP>
        <FP SOURCE="FP1-2">Oxygen and Nitrogen</FP>
        <FP SOURCE="FP1-2">Potassium Iodide</FP>
        <FP SOURCE="FP1-2">Sodium Chloride (Brine Mining Process)</FP>
        <FP SOURCE="FP1-2">Sodium Hydrosulfide</FP>
        <FP SOURCE="FP1-2">Sodium Hydrosulfite</FP>
        <FP SOURCE="FP1-2">Sodium Metal</FP>
        <FP SOURCE="FP1-2">Sodium Silicate</FP>
        <FP SOURCE="FP1-2">Sodium Thiosulfate</FP>
        <FP SOURCE="FP1-2">Sulfur Dioxide</FP>
        <FP SOURCE="FP1-2">Sulfuric Acid</FP>
        <FP SOURCE="FP-2">
          <E T="03">Leather</E> (40 CFR part 425)</FP>
        <FP SOURCE="FP1-2">Gloves</FP>
        <FP SOURCE="FP1-2">Luggage</FP>
        <FP SOURCE="FP-2">
          <E T="03">Paving and Roofing</E> (40 CFR part 443)</FP>
        <FP SOURCE="FP1-2">Asphalt Concrete</FP>
        <FP SOURCE="FP1-2">Asphalt Emulsion</FP>
        <FP SOURCE="FP1-2">Linoleum</FP>
        <FP SOURCE="FP1-2">Printed Asphalt Felt</FP>
        <FP SOURCE="FP1-2">Roofing<PRTPAGE P="51"/>
        </FP>
        <FP SOURCE="FP-2">
          <E T="03">Pulp, Paper, and Paperboard, and Builders’ Paper and Board Mills</E> (40 CFR parts 430 and 431)</FP>
        <FP SOURCE="FP1-2">Groundwood-Chemi-Mechanical</FP>
        <FP SOURCE="FP-2">
          <E T="03">Rubber Manufacturing</E> (40 CFR part 428)</FP>
        <FP SOURCE="FP1-2">Tire and Inner Tube Plants</FP>
        <FP SOURCE="FP1-2">Emulsion Crumb Rubber</FP>
        <FP SOURCE="FP1-2">Solution Crumb Rubber</FP>
        <FP SOURCE="FP1-2">Latex Rubber</FP>
        <FP SOURCE="FP1-2">Small-sized General Molded, Extruded and Fabricated Rubber Plants,<SU>2</SU>
          <FTREF/>
        </FP>
        <FTNT>
          <P>
            <SU>2</SU> Footnote: Except for production attributed to lead-sheathed hose manufacturing operations.</P>
        </FTNT>
        <FP SOURCE="FP1-2">Medium-sided General Molded, Extruded and Fabricated Rubber Plants <SU>2</SU>
        </FP>
        <FP SOURCE="FP1-2">Large-sized General Molded, Extruded and Fabricated Rubber Plants <SU>2</SU>
        </FP>
        <FP SOURCE="FP1-2">Wet Digestion Reclaimed Rubber</FP>
        <FP SOURCE="FP1-2">Pan, Dry Digestion, and Mechanical Reclaimed Rubber</FP>
        <FP SOURCE="FP1-2">Latex Dipped, Latex-Extruded, and Latex-Molded Rubber <SU>3</SU>
          <FTREF/>
        </FP>
        <FTNT>
          <P>
            <SU>3</SU> Footnote: Except for production attributed to chromic acid form-cleaning operations.</P>
        </FTNT>
        <FP SOURCE="FP1-2">Latex Foam <SU>4</SU>
          <FTREF/>
        </FP>
        <FTNT>
          <P>
            <SU>4</SU> Footnote: Except for production that generates zinc as a pollutant in discharge.</P>
        </FTNT>
        <FP SOURCE="FP-2">
          <E T="03">Soap and Detergent Manufacturing</E> (40 CFR part 417)</FP>
        <FP SOURCE="FP1-2">Soap Manufacture by Batch Kettle</FP>
        <FP SOURCE="FP1-2">Fatty Acid Manufacture by Fat Splitting</FP>
        <FP SOURCE="FP1-2">Soap Manufacture by Fatty Acid</FP>
        <FP SOURCE="FP1-2">Neutralization</FP>
        <FP SOURCE="FP1-2">Glycerine Concentration</FP>
        <FP SOURCE="FP1-2">Glycerine Distillation</FP>
        <FP SOURCE="FP1-2">Manufacture of Soap Flakes and Powders</FP>
        <FP SOURCE="FP1-2">Manufacture of Bar Soaps</FP>
        <FP SOURCE="FP1-2">Manufacture of Liquid Soaps</FP>
        <FP SOURCE="FP1-2">Manufacture of Spray Dried Detergents</FP>
        <FP SOURCE="FP1-2">Manufacture of Liquid Detergents</FP>
        <FP SOURCE="FP1-2">Manufacture of Dry Blended Detergents</FP>
        <FP SOURCE="FP1-2">Manufacture of Drum Dried Detergents</FP>
        <FP SOURCE="FP1-2">Manufacture of Detergent Bars and Cakes</FP>
        <FP SOURCE="FP-2">
          <E T="03">Textile Mills</E> (40 CFR part 410)</FP>
        <FP SOURCE="FP1-2">Apparel manufacturing</FP>
        <FP SOURCE="FP1-2">Cordage and Twine</FP>
        <FP SOURCE="FP1-2">Padding and Upholstery Filling</FP>
        <FP SOURCE="FP-2">
          <E T="03">Timber Products Processing</E> (40 CFR part 429)</FP>
        <FP SOURCE="FP1-2">Barking Process</FP>
        <FP SOURCE="FP1-2">Finishing Processes</FP>
        <FP SOURCE="FP1-2">Hardboard—Dry Process</FP>
        <CITA>[51 FR 36372, Oct. 9, 1986]</CITA>
      </APPENDIX>
      <APPENDIX>
        <EAR>Pt. 403, App. E</EAR>
        <HD SOURCE="HED">Appendix E to Part 403—Sampling Procedures</HD>
        <HD SOURCE="HD1">I. Composite Method</HD>
        <P>A. It is recommended that influent and effluent operational data be obtained through 24-hour flow proportional composite samples. Sampling may be done manually or automatically, and discretely or continuously. If discrete sampling is employed, at least 12 aliquots should be composited. Discrete sampling may be flow proportioned either by varying the time interval between each aliquot or the volume of each aliquot. All composites should be flow proportional to either the stream flow at the time of collection of the influent aliquot or to the total influent flow since the previous influent aliquot. Volatile pollutant aliquots must be combined in the laboratory immediately before analysis.</P>
        <P>B. Effluent sample collection need not be delayed to compensate for hydraulic detention unless the POTW elects to include detention time compensation or unless the Approval Authority requires detention time compensation. The Approval Authority may require that each effluent sample is taken approximately one detention time later than the corresponding influent sample when failure to do so would result in an unrepresentative portrayal of actual POTW operation. The detention period should be based on a 24-hour average daily flow value. The average daily flow should in turn be based on the average of the daily flows during the same month of the previous year.</P>
        <HD SOURCE="HD1">II. Grab Method</HD>
        <P>If composite sampling is not an appropriate technique, grab samples should be taken to obtain influent and effluent operational data. A grab sample is an individual sample collected over a period of time not exceeding 15 minutes. The collection of influent grab samples should precede the collection of effluent samples by approximately one detention period except that where the detention period is greater than 24 hours such staggering of the sample collection may not be necessary or appropriate. The detention period should be based on a 24-hour average daily flow value. The average daily flow should in turn be based upon the average of the daily flows during the same month of the previous year. Grab sampling should be employed where the pollutants being evaluated are those, such as cyanide and phenol, which may not be held for an extended period because of biological, chemical or physical interaction which take place after sample collection and affect the results.</P>
        <CITA>[49 FR 31225, Aug. 3, 1984]</CITA>
      </APPENDIX>
      <APPENDIX>
        <EAR>Pt. 403, App. G</EAR>
        <HD SOURCE="HED">Appendix G To Part 403—Pollutants Eligible for a Removal Credit</HD>
        <GPOTABLE CDEF="s25,xs30,xs30,xs30" COLS="4" OPTS="L2,i1">
          <TTITLE>I. Regulated Pollutants in Part 503 Eligible for a Removal Credit</TTITLE>
          <BOXHD>
            <CHED H="1">Pollutants</CHED>
            <CHED H="1">Use or disposal practice</CHED>
            <CHED H="2">LA</CHED>
            <CHED H="2">SD</CHED>
            <CHED H="2">I</CHED>
          </BOXHD>
          <ROW>
            <ENT I="01">Arsenic </ENT>
            <ENT O="xl">X</ENT>
            <ENT O="xl">X</ENT>
            <ENT>X</ENT>
          </ROW>
          <ROW>
            <PRTPAGE P="52"/>
            <ENT I="01">Beryllium</ENT>
            <ENT/>
            <ENT/>
            <ENT>X</ENT>
          </ROW>
          <ROW>
            <ENT I="01">Cadmium </ENT>
            <ENT O="xl">X</ENT>
            <ENT/>
            <ENT>X</ENT>
          </ROW>
          <ROW>
            <ENT I="01">Chromium</ENT>
            <ENT/>
            <ENT O="xl">X</ENT>
            <ENT>X</ENT>
          </ROW>
          <ROW>
            <ENT I="01">Copper </ENT>
            <ENT O="xl">X</ENT>
            <ENT O="xl"/>
            <ENT O="xl"/>
          </ROW>
          <ROW>
            <ENT I="01">Lead </ENT>
            <ENT O="xl">X</ENT>
            <ENT/>
            <ENT>X</ENT>
          </ROW>
          <ROW>
            <ENT I="01">Mercury </ENT>
            <ENT O="xl">X</ENT>
            <ENT/>
            <ENT>X</ENT>
          </ROW>
          <ROW>
            <ENT I="01">Molybdenum </ENT>
            <ENT O="xl">X</ENT>
            <ENT O="xl"/>
            <ENT O="xl"/>
          </ROW>
          <ROW>
            <ENT I="01">Nickel </ENT>
            <ENT O="xl">X </ENT>
            <ENT O="xl">X</ENT>
            <ENT>X</ENT>
          </ROW>
          <ROW>
            <ENT I="01">Selenium </ENT>
            <ENT O="xl">X</ENT>
            <ENT O="xl"/>
            <ENT O="xl"/>
          </ROW>
          <ROW>
            <ENT I="01">Zinc </ENT>
            <ENT O="xl">X</ENT>
            <ENT/>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Total hydrocarbons</ENT>
            <ENT/>
            <ENT/>
            <ENT>X <SU>1</SU>
            </ENT>
          </ROW>
          <TNOTE>Key:</TNOTE>
          <TNOTE>LA—land application.</TNOTE>
          <TNOTE>SD—surface disposal site without a liner and leachate collection system.</TNOTE>
          <TNOTE>I—firing of sewage sludge in a sewage sludge incinerator.</TNOTE>
          <TNOTE>
            <SU>1</SU> The following organic pollutants are eligible for a removal credit if the requirements for total hydrocarbons in subpart E in 40 CFR Part 503 are met when sewage sludge is fired in a sewage sludge incinerator: Acrylonitrile, Aldrin/Dieldrin(total), Benzene, Benzidine, Benzo(a)pyrene, Bis(2-chloroethyl)ether, Bis(2-ethylhexyl)phthalate, Bromodichloromethane, Bromoethane, Bromoform, Carbon tetrachloride, Chlordane, Chloroform, Chloromethane, DDD,DDE,DDT, Dibromochloromethane, Dibutyl phthalate, 1,2-dichloroethane, 1,1-dichloroethylene, 2,4-dichlorophenol, 1,3-dichloropropene, Diethyl phthalate, 2,4-dinitrophenol, 1,2-diphenylhydrazine, Di-n-butyl phthalate, Endosulfan, Endrin, Ethylbenzene, Heptachlor, Heptachlor epoxide, Hexachlorobutadiene, Alpha-hexachlorocyclohexane, Beta-hexachlorocyclohexane, Hexachlorocyclopentadiene, Hexachloroethane, Hydrogen cyanide, Isophorone, Lindane, Methylene chloride, Nitrobenzene, N-Nitrosodimethylamine, N-Nitrosodi-n-propylamine, Pentachlorophenol, Phenol, Polychlorinated biphenyls, 2,3,7,8-tetrachlorodibenzo-p-dioxin, 1,1,2,2,-tetrachloroethane, Tetrachloroethylene, Toluene, Toxaphene, Trichloroethylene, 1,2,4-Trichlorobenzene, 1,1,1-Trichloroethane, 1,1,2-Trichloroethane, and 2,4,6-Trichlorophenol.</TNOTE>
        </GPOTABLE>
        <GPOTABLE CDEF="s50,9.1,9.3,9.3,5.1" COLS="5" OPTS="L2,i1">
          <TTITLE>II. Additional Pollutants Eligible for a Removal Credit</TTITLE>
          <TDESC>[Milligrams per kilogram—dry weight basis]</TDESC>
          <BOXHD>
            <CHED H="1">Pollutant</CHED>
            <CHED H="1">Use or disposal practice</CHED>
            <CHED H="2">LA</CHED>
            <CHED H="2">Surface  disposal</CHED>
            <CHED H="3">Unlined <SU>1</SU>
            </CHED>
            <CHED H="3">Lined <SU>2</SU>
            </CHED>
            <CHED H="2">I</CHED>
          </BOXHD>
          <ROW>
            <ENT I="01">Arsenic </ENT>
            <ENT/>
            <ENT/>
            <ENT>
              <SU>3</SU> 100 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Aldrin/Dieldrin (Total) </ENT>
            <ENT>2.7 </ENT>
            <ENT/>
            <ENT/>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Benzene </ENT>
            <ENT>
              <SU>3</SU> 16 </ENT>
            <ENT>140 </ENT>
            <ENT>3400 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Benzo(a)pyrene </ENT>
            <ENT>15 </ENT>
            <ENT>
              <SU>3</SU> 100 </ENT>
            <ENT>
              <SU>3</SU> 100 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Bis(2-ethylhexyl)phthalate </ENT>
            <ENT/>
            <ENT>
              <SU>3</SU> 100 </ENT>
            <ENT>
              <SU>3</SU> 100 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Cadmium </ENT>
            <ENT/>
            <ENT>
              <SU>3</SU> 100 </ENT>
            <ENT>
              <SU>3</SU> 100 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Chlordane </ENT>
            <ENT>86 </ENT>
            <ENT>
              <SU>3</SU> 100 </ENT>
            <ENT>
              <SU>3</SU> 100 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Chromium (total) </ENT>
            <ENT>
              <SU>3</SU> 100 </ENT>
            <ENT/>
            <ENT>
              <SU>3</SU> 100 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Copper </ENT>
            <ENT/>
            <ENT>
              <SU>3</SU> 46   </ENT>
            <ENT>100 </ENT>
            <ENT>1400</ENT>
          </ROW>
          <ROW>
            <ENT I="01">DDD, DDE, DDT (Total) </ENT>
            <ENT>1.2 </ENT>
            <ENT>2000 </ENT>
            <ENT>2000 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">2,4 Dichlorophenoxy-acetic acid </ENT>
            <ENT/>
            <ENT>7 </ENT>
            <ENT>7 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Fluoride </ENT>
            <ENT>730 </ENT>
            <ENT/>
            <ENT/>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Heptachlor </ENT>
            <ENT>7.4 </ENT>
            <ENT/>
            <ENT/>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Hexachlorobenzene </ENT>
            <ENT>29 </ENT>
            <ENT/>
            <ENT/>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Hexachlorobutadiene </ENT>
            <ENT>600 </ENT>
            <ENT/>
            <ENT/>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Iron </ENT>
            <ENT>
              <SU>3</SU> 78 </ENT>
            <ENT/>
            <ENT/>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Lead </ENT>
            <ENT/>
            <ENT>
              <SU>3</SU> 100 </ENT>
            <ENT>
              <SU>3</SU> 100 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Lindane </ENT>
            <ENT>84 </ENT>
            <ENT>
              <SU>3</SU> 28 </ENT>
            <ENT>
              <SU>3</SU> 28 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Malathion </ENT>
            <ENT/>
            <ENT>0.63 </ENT>
            <ENT>0.63 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Mercury </ENT>
            <ENT/>
            <ENT>
              <SU>3</SU> 100 </ENT>
            <ENT>
              <SU>3</SU> 100 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Molybdenum </ENT>
            <ENT/>
            <ENT>40 </ENT>
            <ENT>40 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Nickel </ENT>
            <ENT/>
            <ENT/>
            <ENT>
              <SU>3</SU> 100 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">N-Nitrosodimethylamine</ENT>
            <ENT>2.1 </ENT>
            <ENT>0.088 </ENT>
            <ENT>0.088 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Pentachlorophenol </ENT>
            <ENT>30 </ENT>
            <ENT/>
            <ENT/>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Phenol </ENT>
            <ENT/>
            <ENT>82 </ENT>
            <ENT>82 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Polychlorinated biphenyls </ENT>
            <ENT>4.6 </ENT>
            <ENT>&lt;50 </ENT>
            <ENT>&lt;50 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Selenium </ENT>
            <ENT/>
            <ENT>4.8 </ENT>
            <ENT>4.8 </ENT>
            <ENT>4.8</ENT>
          </ROW>
          <ROW>
            <ENT I="01">Toxaphene </ENT>
            <ENT>10 </ENT>
            <ENT>
              <SU>3</SU> 26 </ENT>
            <ENT>
              <SU>3</SU> 26 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Trichloroethylene </ENT>
            <ENT>
              <SU>3</SU> 10 </ENT>
            <ENT>9500 </ENT>
            <ENT>
              <SU>3</SU> 10 </ENT>
            <ENT/>
          </ROW>
          <ROW>
            <ENT I="01">Zinc </ENT>
            <ENT/>
            <ENT>4500 </ENT>
            <ENT>4500 </ENT>
            <ENT>4500</ENT>
          </ROW>
          <TNOTE>
            <SU>1</SU> Active sewage sludge unit without a liner and leachate collection system.</TNOTE>
          <TNOTE>
            <SU>2</SU> Active sewage sludge unit with a liner and leachate collection system.</TNOTE>
          <TNOTE>
            <SU>3</SU> Value expressed in grams per kilogram—dry weight basis.</TNOTE>
          <TNOTE>
            <E T="02">Key:</E> LA—land application.</TNOTE>
          <TNOTE>I—incineration.</TNOTE>
        </GPOTABLE>
        <CITA TYPE="W">[60 FR 54768, Oct. 25, 1995, as amended at 65 FR 42567, Aug. 4, 1999]</CITA>
      </APPENDIX>
    </PART>
    <PART>
      <PRTPAGE P="53"/>
      <EAR>Pt. 405</EAR>
      <HD SOURCE="HED">PART 405—DAIRY PRODUCTS PROCESSING POINT SOURCE CATEGORY</HD>
      <CONTENTS>
        <SUBPART>
          <HD SOURCE="HED">Subpart A—Receiving Stations Subcategory</HD>
          <SECHD>Sec.</SECHD>
          <SECTNO>405.10</SECTNO>
          <SUBJECT>Applicability; description of the receiving stations subcategory.</SUBJECT>
          <SECTNO>405.11</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>405.12</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>405.13</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>405.14</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>405.15</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>405.16</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>405.17</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart B—Fluid Products Subcategory</HD>
          <SECTNO>405.20</SECTNO>
          <SUBJECT>Applicability; description of the fluid products subcategory.</SUBJECT>
          <SECTNO>405.21</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>405.22</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>405.23</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>405.24</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>405.25</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>405.26</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>405.27</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart C—Cultured Products Subcategory</HD>
          <SECTNO>405.30</SECTNO>
          <SUBJECT>Applicability; description of the cultured products subcategory.</SUBJECT>
          <SECTNO>405.31</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>405.32</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>405.33</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>405.34</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>405.35</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>405.36</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>405.37</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart D—Butter Subcategory</HD>
          <SECTNO>405.40</SECTNO>
          <SUBJECT>Applicability; description of the butter subcategory.</SUBJECT>
          <SECTNO>405.41</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>405.42</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>405.43</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>405.44</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>405.45</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>405.46</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>405.47</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart E—Cottage Cheese and Cultured Cream Cheese Subcategory</HD>
          <SECTNO>405.50</SECTNO>
          <SUBJECT>Applicability; description of the cottage cheese and cultured cream cheese subcategory.</SUBJECT>
          <SECTNO>405.51</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>405.52</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>405.53</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>405.54</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>405.55</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>405.56</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>405.57</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart F—Natural and Processed Cheese Subcategory</HD>
          <SECTNO>405.60</SECTNO>
          <SUBJECT>Applicability; description of the natural and processed cheese subcategory.</SUBJECT>
          <SECTNO>405.61</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>405.62</SECTNO>

          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best <PRTPAGE P="54"/>practicable control technology currently available.</SUBJECT>
          <SECTNO>405.63</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>405.64</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>405.65</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>405.66</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>405.67</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart G—Fluid Mix for Ice Cream and Other Frozen Desserts Subcategory</HD>
          <SECTNO>405.70</SECTNO>
          <SUBJECT>Applicability; description of the fluid mix for ice cream and other frozen desserts subcategory.</SUBJECT>
          <SECTNO>405.71</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>405.72</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>405.73</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>405.74</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>405.75</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>405.76</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>405.77</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart H—Ice Cream, Frozen Desserts, Novelties and Other Dairy Desserts Subcategory</HD>
          <SECTNO>405.80</SECTNO>
          <SUBJECT>Applicability; description of the ice cream, frozen desserts, novelties and other dairy desserts subcategory.</SUBJECT>
          <SECTNO>405.81</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>405.82</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>405.83</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>405.84</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>405.85</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>405.86</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>405.87</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart I—Condensed Milk Subcategory</HD>
          <SECTNO>405.90</SECTNO>
          <SUBJECT>Applicability; description of the condensed milk subcategory.</SUBJECT>
          <SECTNO>405.91</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>405.92</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>405.93</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>405.94</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>405.95</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>405.96</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>405.97</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart J—Dry Milk Subcategory</HD>
          <SECTNO>405.100</SECTNO>
          <SUBJECT>Applicability; description of the dry milk subcategory.</SUBJECT>
          <SECTNO>405.101</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>405.102</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>405.103</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>405.104</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>405.105</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>405.106</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>405.107</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart K—Condensed Whey Subcategory</HD>
          <SECTNO>405.110</SECTNO>
          <SUBJECT>Applicability; description of the condensed whey subcategory.</SUBJECT>
          <SECTNO>405.111</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>405.112</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>405.113</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>405.114</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>405.115</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>405.116</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>405.117</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <PRTPAGE P="55"/>
          <HD SOURCE="HED">Subpart L—Dry Whey Subcategory</HD>
          <SECTNO>405.120</SECTNO>
          <SUBJECT>Applicability; description of the dry whey subcategory.</SUBJECT>
          <SECTNO>405.121</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>405.122</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>405.123</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>405.124</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>405.125</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>405.126</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>405.127</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
      </CONTENTS>
      <AUTH>
        <HD SOURCE="HED">Authority:</HD>
        <P>Secs. 301, 304 (b) and (c), 306 (b) and (c) and 307(c) of the Federal Water Pollution Control Act, as amended (the Act); 33 U.S.C. 1251, 1311, 1314 (b) and (c), 1316 (b) and (c), and 1317(c); 86 Stat. 816, et seq., Pub. L. 92-500; 91 Stat. 1567, Pub. L. 95-217.</P>
      </AUTH>
      <SOURCE>
        <HD SOURCE="HED">Source:</HD>
        <P>39 FR 18597, May 28, 1974, unless otherwise noted.</P>
      </SOURCE>
      <SUBPART>
        <HD SOURCE="HED">Subpart A—Receiving Stations Subcategory</HD>
        <SECTION>
          <SECTNO>§ 405.10</SECTNO>
          <SUBJECT>Applicability; description of the receiving stations subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the operation of receiving stations engaged in the assembly and reshipment of bulk milk for the use of manufacturing or processing plants.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.11</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term “BOD<E T="03">5</E> input” shall mean the biochemical oxygen demand of the materials entered into process. It can be calculated by multiplying the fats, proteins and carbohydrates by factors of 0.890, 1.031 and 0.691 respectively. Organic acids (e.g., lactic acids) should be included as carbohydrates. Composition of input materials may be based on either direct analyses or generally accepted published values.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.12</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) For receiving stations receiving more than 150,000 lb/day of milk equivalent (15,600 lb/day or more of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.475</ENT>
              <ENT>0.190</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.713</ENT>
              <ENT>.285</ENT>
            </ROW>
            <ROW RUL="n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.048</ENT>
              <ENT>0.019</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.071</ENT>
              <ENT>.029</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(b) For receiving stations receiving 150,000 lb/day or less of milk equivalent (under 15,600 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.625</ENT>
              <ENT>0.313</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.938</ENT>
              <ENT>.469</ENT>
            </ROW>
            <ROW RUL="n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.063</ENT>
              <ENT>0.031</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.094</ENT>
              <ENT>.047</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 18597, May 28, 1974, as amended at 60 FR 33933, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <PRTPAGE P="56"/>
          <SECTNO>§ 405.13</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.14</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6434, Feb. 11, 1975, as amended at 60 FR 33933, June 29, 1995]</CITA>
          
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.15</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.100</ENT>
              <ENT>0.050</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.126</ENT>
              <ENT>.063</ENT>
            </ROW>
            <ROW RUL="n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.010</ENT>
              <ENT>0.005</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.013</ENT>
              <ENT>.006</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.16</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33933, June 29, 1995]</CITA>
          
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.17</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 405.12 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24996, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart B—Fluid Products Subcategory</HD>
        <SECTION>
          <SECTNO>§ 405.20</SECTNO>
          <SUBJECT>Applicability; description of the fluid products subcategory.</SUBJECT>

          <P>The provisions of this subpart are applicable to discharges resulting from the manufacture of market milk (ranging from 3.5 percent fat to fat-free), flavored milk (chocolate and others) and cream (of various fat concentrations, plain and whipped).
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.21</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term “BOD<E T="03">5</E> input” shall mean the biochemical oxygen demand of the materials entered into process. It can be calculated by multiplying the fats, proteins and carbohydrates by factors of 0.890, 1.031 and 0.691 respectively. Organic acids (e.g., lactic acids) should be included as carbohydrates. Composition of input materials may be based on either direct analyses or generally accepted published values.
          </P>
        </SECTION>
        <SECTION>
          <PRTPAGE P="57"/>
          <SECTNO>§ 405.22</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) For fluid products plants receiving more than 250,000 lb/day of milk equivalent (more than 25,900 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>3.375</ENT>
              <ENT>1.350</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>5.506</ENT>
              <ENT>2.025</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.338</ENT>
              <ENT>0.135</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.551</ENT>
              <ENT>.203</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(b) For fluid products plants receiving 250,000 lb/day or less of milk equivalent (less than 25,900 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>4.50</ENT>
              <ENT>2.250</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>6.750</ENT>
              <ENT>3.375</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.450</ENT>
              <ENT>0.225</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.675</ENT>
              <ENT>.338</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 18597, May 28, 1974, as amended at 39 FR 32994, Sept. 13, 1974; 60 FR 33933, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.23</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.24</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6434, Feb. 11, 1975, as amended at 60 FR 33933, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.25</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.740</ENT>
              <ENT>0.370</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.925</ENT>
              <ENT>.463</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.074</ENT>
              <ENT>0.037</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.093</ENT>
              <ENT>.046</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.26</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33933, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <PRTPAGE P="58"/>
          <SECTNO>§ 405.27</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 405.22 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24996, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart C—Cultured Products Subcategory</HD>
        <SECTION>
          <SECTNO>§ 405.30</SECTNO>
          <SUBJECT>Applicability; description of the cultured products subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable discharges resulting from the manufacture of cultured products, including cultured skim milk (cultured buttermilk), yoghurt, sour cream and dips of various types.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.31</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term “BOD<E T="03">5</E> input” shall mean the biochemical oxygen demand of the materials entered into process. It can be calculated by multiplying the fats, proteins and carbohydrates by factors of 0.890, 1.031 and 0.691 respectively. Organic acids (e.g., lactic acids) should be included as carbohydrates. Composition of input materials may be based on either direct analyses or generally accepted published values.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.32</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) For cultured products plants receiving more than 60,000 lb/day of milk equivalent (more than 6,200 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>3.375</ENT>
              <ENT>1.350</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>5.063</ENT>
              <ENT>2.025</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.338</ENT>
              <ENT>0.135</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.506</ENT>
              <ENT>.203</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(b) For cultured products plants receiving 60,000 lb/day or less of milk equivalent (less than 6,200 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>4.50</ENT>
              <ENT>2.250</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>6.750</ENT>
              <ENT>.3.375</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.450</ENT>
              <ENT>0.225</ENT>
            </ROW>
            <ROW>
              <PRTPAGE P="59"/>
              <ENT I="01">TSS</ENT>
              <ENT>0.675</ENT>
              <ENT>.338</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 18597, May 28, 1974, as amended at 60 FR 33933, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.33</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.34</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6434, Feb. 11, 1975, as amended at 60 FR 33933, June 29, 1995]</CITA>
          
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.35</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.740</ENT>
              <ENT>0.370</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.926</ENT>
              <ENT>.463</ENT>
            </ROW>
            <ROW RUL="n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.074</ENT>
              <ENT>0.037</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.093</ENT>
              <ENT>.046</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.36</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33933, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.37</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 405.32 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24996, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart D—Butter Subcategory</HD>
        <SECTION>
          <SECTNO>§ 405.40</SECTNO>
          <SUBJECT>Applicability; description of the butter subcategory.</SUBJECT>

          <P>The provisions of this subpart are applicable to discharges resulting from the manufacture of butter, either by churning or continuous process.
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.41</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>

          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part <PRTPAGE P="60"/>401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term “BOD<E T="03">5</E> input” shall mean the biochemical oxygen demand of the materials entered into process. It can be calculated by multiplying the fats, proteins and carbohydrates by factors of 0.890, 1.031 and 0.691 respectively. Organic acids (e.g., lactic acids) should be included as carbohydrates. Composition of input materials may be based on either direct analyses or generally accepted published values.
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.42</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) For plants processing more than 175,000 lb/day of milk equivalent (more than 18,180 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.375</ENT>
              <ENT>0.550</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.063</ENT>
              <ENT>.825</ENT>
            </ROW>
            <ROW RUL="n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.138</ENT>
              <ENT>0.055</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.206</ENT>
              <ENT>.083</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(b) For plants processing 175,000 lb/day or less of milk equivalent (less than 18,180 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.825</ENT>
              <ENT>0.913</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.738</ENT>
              <ENT>1.369</ENT>
            </ROW>
            <ROW RUL="n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.183</ENT>
              <ENT>0.091</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>.274</ENT>
              <ENT>.137</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          
          <CITA>[39 FR 18597, May 28, 1974, as amended at 60 FR 33933, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.43</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.44</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6434, Feb. 11, 1975, as amended at 60 FR 33933, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.45</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>

          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:<PRTPAGE P="61"/>
          </P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.160</ENT>
              <ENT>0.080</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.20</ENT>
              <ENT>.10</ENT>
            </ROW>
            <ROW RUL="n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.016</ENT>
              <ENT>0.008</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.020</ENT>
              <ENT>.010</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.46</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33934, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.47</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 405.42 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24996, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart E—Cottage Cheese and Cultured Cream Cheese Subcategory</HD>
        <SECTION>
          <SECTNO>§ 405.50</SECTNO>
          <SUBJECT>Applicability; description of the cottage cheese and cultured cream cheese subcategory.</SUBJECT>

          <P>The provisions of this subpart are applicable to discharges resulting from the manufacture of cottage cheese and cultured cream cheese.
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.51</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term “BOD<E T="03">5</E> input” shall mean the biochemical oxygen demand of the materials entered into process. It can be calculated by multiplying the fats, proteins and carbohydrates by factors of 0.890, 1.031 and 0.691 respectively. Organic acids (e.g., lactic acids) should be included as carbohydrates. Composition of input materials may be based on either direct analyses or generally accepted published values.
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.52</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) For plants processing more than 25,000 lb/day of milk equivalent (more than 2,600 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>6.70</ENT>
              <ENT>2.680</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>10.050</ENT>
              <ENT>4.020</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.670</ENT>
              <ENT>0.268</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.005</ENT>
              <ENT>.402</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <PRTPAGE P="62"/>

          <P>(b) For plants processing 25,000 lb/day or less of milk equivalent (less than 2,600 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>8.926</ENT>
              <ENT>4.463</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>13.388</ENT>
              <ENT>6.694</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.893</ENT>
              <ENT>0.446</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.339</ENT>
              <ENT>.669</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 18597, May 28, 1974, as amended at 60 FR 33934, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.53</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.54</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6434, Feb. 11, 1975, as amended at 60 FR 33934, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.55</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.480</ENT>
              <ENT>0.740</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.850</ENT>
              <ENT>.925</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.148</ENT>
              <ENT>0.074</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.185</ENT>
              <ENT>.093</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.56</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33934, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.57</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 405.52 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24996, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart F—Natural and Processed Cheese Subcategory</HD>
        <SECTION>
          <SECTNO>§ 405.60</SECTNO>
          <SUBJECT>Applicability; description of the natural and processed cheese subcategory.</SUBJECT>

          <P>The provisions of this subpart are applicable to discharges resulting from the manufacture of natural cheese (hard curd) and processed cheese.
          </P>
        </SECTION>
        <SECTION>
          <PRTPAGE P="63"/>
          <SECTNO>§ 405.61</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter, shall apply to this subpart.</P>
          <P>(b) The term “BOD<E T="03">5</E> input” shall mean the biochemical oxygen demand of the materials entered into process. It can be calculated by multiplying the fats, proteins and carbohydrates by factors of 0.890, 1.031 and 0.691 respectively. Organic acids (e.g., lactic acids) should be included as carbohydrates. Composition of input materials may be based on either direct analyses or generally accepted published values.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.62</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) For plants processing more than 100,000 lb/day of milk equivalent (more than 10,390 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.716</ENT>
              <ENT>0.290</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.088</ENT>
              <ENT>.435</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.073</ENT>
              <ENT>0.029</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.109</ENT>
              <ENT>.044</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(b) For plants processing 100,000 lb/day or less of milk equivalent (less than 10,390 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.976</ENT>
              <ENT>0.488</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.462</ENT>
              <ENT>.731</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.098</ENT>
              <ENT>0.049</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.146</ENT>
              <ENT>.073</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          
          <CITA>[39 FR 18597, May 28, 1974, as amended at 39 FR 32993, Sept. 13, 1974; 60 FR 33934, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.63</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.64</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6434, Feb. 11, 1975, as amended at 60 FR 33934, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.65</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>

          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:<PRTPAGE P="64"/>
          </P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.160</ENT>
              <ENT>0.080</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.20</ENT>
              <ENT>.10</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.016</ENT>
              <ENT>0.008</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.020</ENT>
              <ENT>.010</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.66</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33934, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.67</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 405.62 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24996, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart G—Fluid Mix for Ice Cream and Other Frozen Desserts Subcategory</HD>
        <SECTION>
          <SECTNO>§ 405.70</SECTNO>
          <SUBJECT>Applicability; description of the fluid mix for ice cream and other frozen desserts subcategory.</SUBJECT>

          <P>The provisions of this subpart are applicable to discharges resulting from the manufacture of fluid mixes for ice cream and other frozen desserts for later freezing in other plants; it does not include freezing of the products as one of the affected operations.
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.71</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term “BOD<E T="03">5</E> input” shall mean the biochemical oxygen demand of the materials entered into process. It can be calculated by multiplying the fats, proteins and carbohydrates by factors of 0.890, 1.031 and 0.691 respectively. Organic acids (e.g., lactic acids) should be included as carbohydrates. Composition of input materials may be based on either direct analyses or generally accepted published values.
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.72</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) For plants with a dairy products input of more than 85,000 lb/day of milk equivalent (more than 8,830 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>2.20</ENT>
              <ENT>0.880</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>3.30</ENT>
              <ENT>1.320</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.220</ENT>
              <ENT>0.068</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.330</ENT>
              <ENT>.132</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <PRTPAGE P="65"/>

          <P>(b) For plants with a dairy products input of 85,000 lb/day or less of milk equivalent (less than 8.830 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>2.926</ENT>
              <ENT>1.463</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>4.388</ENT>
              <ENT>2.194</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.293</ENT>
              <ENT>0.146</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.439</ENT>
              <ENT>.219</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 18597, May 28, 1974, as amended at 39 FR 32993, Sept. 13, 1974; 60 FR 33934, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.73</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.74</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">Pretreatment standard</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6435, Feb. 11, 1975, as amended at 60 FR 33934, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.75</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.480</ENT>
              <ENT>0.240</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.60</ENT>
              <ENT>.30</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.048</ENT>
              <ENT>0.024</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.060</ENT>
              <ENT>.030</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.76</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33934, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.77</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 405.72 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24996, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart H—Ice Cream, Frozen Desserts, Novelties and Other Dairy Desserts Subcategory</HD>
        <SECTION>
          <SECTNO>§ 405.80</SECTNO>
          <SUBJECT>Applicability; description of the ice cream, frozen desserts, novelties and other dairy desserts subcategory.</SUBJECT>

          <P>The provisions of this subpart are applicable to discharges resulting from <PRTPAGE P="66"/>the manufacture of ice cream, ice milk, sherbert, water ices, stick confections, frozen novelties products, frozen desserts, melorine, pudding and other dairy product base desserts. If fluid mixes prepared at another plant are employed, the appropriate values from subpart G should be deducted from the limitations.
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.81</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter, shall apply to this subpart.</P>
          <P>(b) The term “BOD<E T="03">5</E> input” shall mean the biochemical oxygen demand of the materials entered into process. It can be calculated by multiplying the fats, proteins and carbohydrates by factors of 0.890, 1.031 and 0.691 respectively. Organic acids (e.g., lactic acids) should be included as carbohydrates. Composition of input materials may be based on either direct analyses or generally accepted published values.
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.82</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) For plants with a dairy products input of more than 85,000 lb/day of milk equivalent (more than 8,830 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>4.60</ENT>
              <ENT>1.840</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>6.90</ENT>
              <ENT>2.760</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.460</ENT>
              <ENT>0.184</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>.690</ENT>
              <ENT>0.276</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(b) For plants with a dairy products input of 85,000 lb/day or less of milk equivalent (less than 8,830 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>6.126</ENT>
              <ENT>3.063</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>9.188</ENT>
              <ENT>4.594</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.613</ENT>
              <ENT>0.306</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>.919</ENT>
              <ENT>.459</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 18597, May 28, 1974, as amended at 60 FR 33934, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.83</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.84</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <PRTPAGE P="67"/>
          <CITA>[40 FR 6435, Feb. 11, 1975, as amended at 60 FR 33934, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.85</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.940</ENT>
              <ENT>0.470</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.175</ENT>
              <ENT>.588</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.094</ENT>
              <ENT>0.047</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.118</ENT>
              <ENT>.059</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.86</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33934, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.87</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 405.82 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24996, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart I—Condensed Milk Subcategory</HD>
        <SECTION>
          <SECTNO>§ 405.90</SECTNO>
          <SUBJECT>Applicability; description of the condensed milk subcategory.</SUBJECT>

          <P>The provisions of this subpart are applicable to discharges resulting from the manufacture of condensed whole milk, condensed skim milk, sweetened condensed milk and condensed buttermilk.
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.91</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term “BOD<E T="03">5</E> input” shall mean the biochemical oxygen demand of the materials entered into process. It can be calculated by multiplying the fats, proteins and carbohydrates by factors of 0.890, 1.031 and 0.691 respectively. Organic acids (e.g., lactic acids) should be included as carbohydrates. Composition of input materials may be based on either direct analyses or generally accepted published values.
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.92</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) For plants condensing more than 100,000 lb/day of milk equivalent (more than 10,390 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>3.450</ENT>
              <ENT>1.380</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>5.175</ENT>
              <ENT>2.070</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <PRTPAGE P="68"/>
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.345</ENT>
              <ENT>0.138</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.518</ENT>
              <ENT>.207</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(b) For plants condensing 100,000 lb/day or less of milk equivalent (less than 10,390 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>4.60</ENT>
              <ENT>2.30</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>6.90</ENT>
              <ENT>.450</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.460</ENT>
              <ENT>0.230</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.690</ENT>
              <ENT>.345</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(c) For plants in the size range covered by paragraph (b) once-through barometric condenser water may be discharged untreated if the composite net entrainment is below 15 mg/l of BOD<E T="03">5</E> for any one day and below 10 mg/l of BOD<E T="03">5</E> as the average for thirty consecutive days.</P>
          <CITA>[39 FR 18597, May 28, 1974, as amended at 39 FR 32993, Sept. 13, 1974; 60 FR 33935, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.93</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.94</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">Pretreatment standard</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6435, Feb. 11, 1975, as amended at 60 FR 33935, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.95</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.760</ENT>
              <ENT>0.380</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.950</ENT>
              <ENT>.475</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.076</ENT>
              <ENT>0.038</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.095</ENT>
              <ENT>.048</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 18597, May 28, 1974, as amended at 39 FR 32994, Sept. 13, 1974]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.96</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33935, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.97</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall <PRTPAGE P="69"/>achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 405.92 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24996, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart J—Dry Milk Subcategory</HD>
        <SECTION>
          <SECTNO>§ 405.100</SECTNO>
          <SUBJECT>Applicability; description of the dry milk subcategory.</SUBJECT>

          <P>The provisions of this subpart are applicable to discharges resulting from the manufacture of dry whole milk, dry skim milk and dry buttermilk.
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.101</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term “BOD<E T="03">5</E> input” shall mean the biochemical oxygen demand of the materials entered into process. It can be calculated by multiplying the fats, proteins and carbohydrates by factors of 0.890, 1.031 and 0.691 respectively. Organic acids (e.g., lactic acids) should be included as carbohydrates. Composition of input materials may be based on either direct analysis or generally accepted published values.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.102</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) For milk drying plants with an input equivalent to more than 145,000 lb/day of milk equivalent (more than 15,070 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.625</ENT>
              <ENT>0.650</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.438</ENT>
              <ENT>.975</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.163</ENT>
              <ENT>0.065</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.244</ENT>
              <ENT>.098</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(b) For milk drying plants with an input equivalent to 145,000 lb/day or less of milk equivalent (less than 15,070 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>2.176</ENT>
              <ENT>1.088</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>3.276</ENT>
              <ENT>1.638</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.218</ENT>
              <ENT>0.109</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.328</ENT>
              <ENT>.164</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 18597, May 28, 1974, as amended at 60 FR 33935, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.103</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.104</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>

          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.<PRTPAGE P="70"/>
          </P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6435, Feb. 11, 1975, as amended at 60 FR 33935, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.105</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)
              </ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.036</ENT>
              <ENT>0.018</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.450</ENT>
              <ENT>.225</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.036</ENT>
              <ENT>0.018</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.045</ENT>
              <ENT>.023</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 18597, May 28, 1974, as amended at 39 FR 32993, Sept. 13, 1974]</CITA>
          
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.106</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33935, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.107</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 405.102 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24996, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart K—Condensed Whey Subcategory</HD>
        <SECTION>
          <SECTNO>§ 405.110</SECTNO>
          <SUBJECT>Applicability; description of the condensed whey subcategory.</SUBJECT>

          <P>The provisions of this subpart are applicable to discharges resulting from the manufacture of condensed sweet whey and condensed acid whey.
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.111</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">BOD5</E> input shall mean the biochemical oxygen demand of the materials entered into process. It can be calculated by multiplying the fats, proteins and carbohydrates by factors of 0.890, 1.031 and 0.691 respectively. Organic acids (e.g., lactic acids) should be included as carbohydrates. Composition of input materials may be based on either direct analyses or generally accepted published values.
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.112</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) For whey condensing plants with over 300,000 lb/day of fluid raw whey input (over 20,700 lb/day of solids or 14,160 lb/day of BOD<E T="03">5</E> input).<PRTPAGE P="71"/>
          </P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.00</ENT>
              <ENT>0.400</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.50</ENT>
              <ENT>.600</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.100</ENT>
              <ENT>0.040</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.150</ENT>
              <ENT>.060</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(b) For whey condensing plants with 300,000 lb/day or less of raw fluid whey input (less than 20,700 lb/day of solids or 14,160 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.30</ENT>
              <ENT>0.650</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.950</ENT>
              <ENT>.975</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.130</ENT>
              <ENT>0.065</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.195</ENT>
              <ENT>.098</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(c) For plants in the size range covered in paragraph (b) once-through barometric condenser water may be discharged untreated if the composite net entrainment is below 15 mg/1 of BOD<E T="03">5</E> for any one day and below 10 mg/1 of BOD<E T="03">5</E> as the average for thirty consecutive days.</P>
          <CITA>[39 FR 18597, May 28, 1974, as amended at 60 FR 33935, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.113</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.114</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6435, Feb. 11, 1975, as amended at 60 FR 33935, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.115</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.220</ENT>
              <ENT>0.110</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.276</ENT>
              <ENT>.138</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.022</ENT>
              <ENT>0.011</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.028</ENT>
              <ENT>.014</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.116</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33935, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <PRTPAGE P="72"/>
          <SECTNO>§ 405.117</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 405.112 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24996, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart L—Dry Whey Subcategory</HD>
        <SECTION>
          <SECTNO>§ 405.120</SECTNO>
          <SUBJECT>Applicability; description of the dry whey subcategory.</SUBJECT>

          <P>The provisions of this subpart are applicable to discharges resulting from the manufacture of sweet or acid dry whey.
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.121</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">BOD5</E> input shall mean the biochemical oxygen demand of the materials entered into process. It can be calculated by multiplying the fats, proteins and carbohydrates by factors of 0.890, 1.031 and 0.691 respectively. Organic acids (e.g., lactic acids) should be included as carbohydrates. Composition of input materials may be based on either direct analyses or generally accepted published values.
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.122</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) For whey drying plants with an input equivalent to more than 57,000 lb/day of 40 percent solids whey (22,800 lb/day of solids or 15,620 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.00</ENT>
              <ENT>0.400</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.50</ENT>
              <ENT>.600</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.100</ENT>
              <ENT>0.040</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.150</ENT>
              <ENT>.060</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(b) For whey drying plants with an input equivalent to 57,000 lb/day or less of 40 percent solids whey (under 22,800 lb/day solids or 15,620 lb/day of BOD<E T="03">5</E> input).</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.30</ENT>
              <ENT>0.650</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.95</ENT>
              <ENT>.975</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.130</ENT>
              <ENT>0.065</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.195</ENT>
              <ENT>.098</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 18597, May 28, 1974, as amended at 60 FR 33935, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <PRTPAGE P="73"/>
          <SECTNO>§ 405.123</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.124</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6435, Feb. 11, 1975, as amended at 60 FR 33935, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.125</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.220</ENT>
              <ENT>0.110</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.275</ENT>
              <ENT>.138</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 100 lb of BOD<E T="03">5</E> input)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.022</ENT>
              <ENT>0.011</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.023</ENT>
              <ENT>.014</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.126</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33935, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 405.127</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 405.122 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24996, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
    </PART>
    <PART>
      <EAR>Pt. 406</EAR>
      <HD SOURCE="HED">PART 406—GRAIN MILLS POINT SOURCE CATEGORY</HD>
      <CONTENTS>
        <SUBPART>
          <HD SOURCE="HED">Subpart A—Corn Wet Milling Subcategory</HD>
          <SECHD>Sec.</SECHD>
          <SECTNO>406.10</SECTNO>
          <SUBJECT>Applicability; description of the corn wet milling subcategory.</SUBJECT>
          <SECTNO>406.11</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>406.12</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>406.13</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>406.14</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>406.15</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>406.16</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>406.17</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart B—Corn Dry Milling Subcategory</HD>
          <SECTNO>406.20</SECTNO>
          <SUBJECT>Applicability; description of the corn dry milling subcategory.</SUBJECT>
          <SECTNO>406.21</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>406.22</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>406.23</SECTNO>
          <SUBJECT>[Reserved]<PRTPAGE P="74"/>
          </SUBJECT>
          <SECTNO>406.24</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>406.25</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>406.26</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>406.27</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart C—Normal Wheat Flour Milling Subcategory</HD>
          <SECTNO>406.30</SECTNO>
          <SUBJECT>Applicability; description of the normal wheat flour milling subcategory.</SUBJECT>
          <SECTNO>406.31</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>406.32</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>406.33</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.</SUBJECT>
          <SECTNO>406.34</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>406.35</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>406.36</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>406.37</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart D—Bulgur Wheat Flour Milling Subcategory</HD>
          <SECTNO>406.40</SECTNO>
          <SUBJECT>Applicability; description of the bulgur wheat flour milling subcategory.</SUBJECT>
          <SECTNO>406.41</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>406.42</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>406.43</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>406.44</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>406.45</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>406.46</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>406.47</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart E—Normal Rice Milling Subcategory</HD>
          <SECTNO>406.50</SECTNO>
          <SUBJECT>Applicability; description of the normal rice milling subcategory.</SUBJECT>
          <SECTNO>406.51</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>406.52</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>406.53</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.</SUBJECT>
          <SECTNO>406.54</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>406.55</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>406.56</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>406.57</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart F—Parboiled Rice Processing Subcategory</HD>
          <SECTNO>406.60</SECTNO>
          <SUBJECT>Applicability; description of the parboiled rice processing subcategory.</SUBJECT>
          <SECTNO>406.61</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>406.62</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>406.63</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>406.64</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>406.65</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>406.66</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>406.67</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart G—Animal Feed Subcategory</HD>
          <SECTNO>406.70</SECTNO>
          <SUBJECT>Applicability; description of the animal feed subcategory.</SUBJECT>
          <SECTNO>406.71</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>406.72</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>406.73</SECTNO>

          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.<PRTPAGE P="75"/>
          </SUBJECT>
          <SECTNO>406.74</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>406.75</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>406.76</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>406.77</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart H—Hot Cereal Subcategory</HD>
          <SECTNO>406.80</SECTNO>
          <SUBJECT>Applicability; description of the hot cereal subcategory.</SUBJECT>
          <SECTNO>406.81</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>406.82</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>406.83</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.</SUBJECT>
          <SECTNO>406.84</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>406.85</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>406.86</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>406.87</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart I—Ready-to-Eat Cereal Subcategory</HD>
          <SECTNO>406.90</SECTNO>
          <SUBJECT>Applicability; description of the ready-to-eat cereal subcategory.</SUBJECT>
          <SECTNO>406.91</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>406.92</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>406.93-406.94</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>406.95</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>406.96</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>406.97</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart J—Wheat Starch and Gluten Subcategory</HD>
          <SECTNO>406.100</SECTNO>
          <SUBJECT>Applicability; description of the wheat starch and gluten subcategory.</SUBJECT>
          <SECTNO>406.101</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>406.102</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>406.103-406.104</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>406.105</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>406.106</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>406.107</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
      </CONTENTS>
      <AUTH>
        <HD SOURCE="HED">Authority:</HD>
        <P>Secs. 301, 304 (b) and (c), 306 (b) and (c), 307(c) of the Federal Water Pollution Control Act, as amended; 33 U.S.C. 1251, 1311, 1314 (b) and (c), 1316 (b) and (c), 1317(c); 86 Stat. 816 et seq., Pub. L. 92-500; 91 Stat. 1567, Pub. L. 95-217.</P>
      </AUTH>
      <SOURCE>
        <HD SOURCE="HED">Source:</HD>
        <P>39 FR 10513, Mar. 20, 1974, unless otherwise noted.</P>
      </SOURCE>
      <SUBPART>
        <HD SOURCE="HED">Subpart A—Corn Wet Milling Subcategory</HD>
        <SECTION>
          <SECTNO>§ 406.10</SECTNO>
          <SUBJECT>Applicability; description of the corn wet milling subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the process in which shelled corn is steeped in a dilute solution of sulfurous acid and then processed by wet means into such products as animal feed, regular and modified starches, corn oil, corn syrup, and dextrose.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.11</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">corn</E> shall mean the shelled corn delivered to a plant before processing.</P>
          <P>(c) The term <E T="03">standard bushel</E> shall mean a bushel of shelled corn weighing 56 pounds.</P>
          <P>(d) The abbreviation <E T="03">MSBu</E> shall mean 1000 standard bushels.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.12</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>

          <P>(a) Except as provided in §§ 125.30 through 125.32, and subject to the provisions in paragraph (b) of this section, any existing point source subject to this subpart shall achieve the following <PRTPAGE P="76"/>effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of corn)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>2.67</ENT>
              <ENT>0.89</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>4.32</ENT>
              <ENT>1.08</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 stdbu of corn)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>150</ENT>
              <ENT>50</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>240</ENT>
              <ENT>60</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(b) The limitations given in paragraph (a) of this section for BOD<E T="03">5</E> and TSS are derived for a point source producing products standards to the corn wet milling industry. For those plants producing modified starches at a rate of at least 15 percent by dry-basis weight of total sweetener and starch products per month for 12 consecutive months, the following limitations should be used to derive an additive adjustment to the discharge allowed by paragraph (a) of this section:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of corn)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.81</ENT>
              <ENT>0.27</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">TSS</ENT>
              <ENT>2.16</ENT>
              <ENT>.54</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 stdbu of corn)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>45</ENT>
              <ENT>15</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>120</ENT>
              <ENT>30</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[39 FR 10513, Mar. 20, 1974, as amended at 42 FR 62371, Dec. 12, 1977; 60 FR 33936, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.13</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.14</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6436, Feb. 11, 1975, as amended at 60 FR 33036, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.15</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of corn)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.08</ENT>
              <ENT>0.36</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.35</ENT>
              <ENT>.45</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 stdbu of corn)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>60</ENT>
              <ENT>20</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>75</ENT>
              <ENT>25</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[41 FR 50823, Nov. 18, 1976]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.16</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>

          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned <PRTPAGE P="77"/>treatment works must comply with 40 CFR part 403. In addition, the provisions set forth in paragraph (a) of this section apply, as well as the following pretreatment standard which establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to publicly owned treatment works by a new source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>

          <P>(a) Process waste water shall not be discharged to a POTW at a flow rate or pollutant mass loading rate which is excessive over any time period during the peak load at a POTW. Excessive discharges are defined as those in which the flow of BOD<E T="03">5</E> or total suspended solids (TSS) exceed the respective values of P from the following formula:
          </P>
          <HD SOURCE="HD1">P = K(Q+R)−S</HD>
          
          <EXTRACT>
            <FP>where:</FP>

            <FP SOURCE="FP-1">P = maximum allowable peak waste load for the new corn wet milling source to be discharged to the POTW (gallons per one hour for flow and pounds per day for BOD<E T="03">5</E> and TSS).</FP>
            <FP SOURCE="FP-1">Q = average existing waste load to POTW.</FP>
            <FP SOURCE="FP-1">R = average waste load for the new corn wet milling source to be discharged to POTW.</FP>
            <FP SOURCE="FP-1">S = existing peak load of POTW.</FP>
            <FP SOURCE="FP-1">K = 2. When the ratio of (S/Q) is greater than 1.5, K = 3.</FP>
          </EXTRACT>
          
          <P>Calculations are to be based on dry weather conditions.</P>
          <CITA>[40 FR 52016, Nov. 7, 1975, as amended at 60 FR 33936, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.17</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.</SUBJECT>
          <P>The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology.</P>
          <P>(a) Subject to the provisions in paragraph (b) of this section, the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of corn)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.08</ENT>
              <ENT>0.36</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.62</ENT>
              <ENT>.54</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 stdbu of corn)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>60</ENT>
              <ENT>20</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>90</ENT>
              <ENT>30</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(b) The limitations given in paragraph (a) of this section for BOD<E T="03">5</E> and TSS are derived for a point source producing products standard to the corn wet milling industry. For those plants producing modified starches at a rate of at least 15 percent by dry-basis weight of total sweetener and starch products per month for 12 consecutive months, the following limitations should be used to derive an additive adjustment to the discharge allowed by paragraph (a) of this section:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of corn)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.43</ENT>
              <ENT>0.14</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">TSS</ENT>
              <ENT>0.66</ENT>
              <ENT>.22</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 stdbu of corn)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>24</ENT>
              <ENT>8</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>36</ENT>
              <ENT>12</ENT>
            </ROW>
          </GPOTABLE>
          <PRTPAGE P="78"/>
          <CITA>[42 FR 62372, Dec. 12, 1977. Redesignated and amended at 44 FR 50739, Aug. 29, 1979]</CITA>
          <EDNOTE>
            <HD SOURCE="HED">Editorial Note:</HD>
            <P>Section 406.17 was indefinitely suspended at 45 FR 45582, July 7, 1980.</P>
          </EDNOTE>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart B—Corn Dry Milling Subcategory</HD>
        <SECTION>
          <SECTNO>§ 406.20</SECTNO>
          <SUBJECT>Applicability; description of the corn dry milling subcategory.</SUBJECT>
          <P>(a) The provisions of this subpart are applicable to discharges resulting from the process in which shelled corn is washed and subsequently milled by dry processes into such products as corn meal, grits, flour, oil, and animal feed.</P>
          <P>(b) The provisions of this subpart do not apply to discharges from subsequent manufacturing operations to produce expanded or extruded feed or feed products.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.21</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">corn</E> shall mean the shelled corn delivered to a plant before processing.</P>
          <P>(c) The term <E T="03">standard bushel</E> shall mean a bushel of shelled corn weighing 56 pounds.</P>
          <P>(d) The abbreviation <E T="03">MSBu</E> shall mean 1000 standard bushels.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.22</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s20,9,15" COLS="3" OPTS="L1,tp0">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of corn)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.21</ENT>
              <ENT>0.07</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.18</ENT>
              <ENT>.06</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 stdbu of corn)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>12.0</ENT>
              <ENT>4.0</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>10.5</ENT>
              <ENT>3.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 10513, Mar. 20, 1974, as amended at 60 FR 33936, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.23</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.24</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6436, Feb. 11, 1975, as amended at 60 FR 33936, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.25</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>

          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this part:<PRTPAGE P="79"/>
          </P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of corn)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.11</ENT>
              <ENT>0.036</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.054</ENT>
              <ENT>0.18</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 stdbu of corn)
              </ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>6.0</ENT>
              <ENT>2.0</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>3.0</ENT>
              <ENT>1.0</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.26</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33936, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.27</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 406.22 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart C—Normal Wheat Flour Milling Subcategory</HD>
        <SECTION>
          <SECTNO>§ 406.30</SECTNO>
          <SUBJECT>Applicability; description of the normal wheat flour milling subcategory.</SUBJECT>

          <P>The provisions of this subpart are applicable to discharges resulting from the processes in which wheat and other grains are milled by dry processes into flour and millfeed.
            
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.31</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.32</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): There shall be no discharge of process waste water pollutants to navigable waters.</P>
          <CITA>[60 FR 33936, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.33</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.</SUBJECT>

          <P>The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: there shall be no discharge of process waste water pollutants to navigable waters.
            
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.34</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>

          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.<PRTPAGE P="80"/>
          </P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6436, Feb. 11, 1975, as amended at 60 FR 33936, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.35</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties which may be discharged by a new source subject to the provisions of this subpart: There shall be no discharge of process waste water pollutants to navigable waters.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.36</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33936, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.37</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 406.32 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart D—Bulgur Wheat Flour Milling Subcategory</HD>
        <SECTION>
          <SECTNO>§ 406.40</SECTNO>
          <SUBJECT>Applicability; description of the bulgur wheat flour milling subcategory.</SUBJECT>

          <P>The provisions of this subpart are applicable to discharges resulting from the process in which wheat is parboiled, dried, and partially debranned in the production of bulgur.
            
          </P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.41</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of the subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">wheat</E> shall mean wheat delivered to a plant before processing.</P>
          <P>(c) The term <E T="03">standard bushel</E> shall mean a bushel of wheat weighing 60 pounds.</P>
          <P>(d) The abbreviation <E T="03">MSBu</E> shall mean 1,000 standard bushels.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.42</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="01,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of wheat)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.025</ENT>
              <ENT>0.0083</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.025</ENT>
              <ENT>.0083</ENT>
            </ROW>
            <ROW RUL="01,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="01,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 stdbu of wheat)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.50</ENT>
              <ENT>0.50</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.50</ENT>
              <ENT>.50</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 10513, Mar. 20, 1974, as amended at 60 FR 33936, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.43</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.44</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>

          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned <PRTPAGE P="81"/>treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6436, Feb. 11, 1975, as amended at 60 FR 33936, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.45</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of wheat)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.015</ENT>
              <ENT>0.005</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.0099</ENT>
              <ENT>.0033</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 stdbu of wheat)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.90</ENT>
              <ENT>0.30</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.60</ENT>
              <ENT>.20</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.46</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33937, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.47</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 406.42 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart E—Normal Rice Milling Subcategory</HD>
        <SECTION>
          <SECTNO>§ 406.50</SECTNO>
          <SUBJECT>Applicability; description of the normal rice milling subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the process in which rice is cleaned and milled by dry processes.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.51</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.52</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): There shall be no discharge of process <PRTPAGE P="82"/>waste water pollutants to navigable waters.</P>
          <CITA>[60 FR 33937, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.53</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.</SUBJECT>
          <P>The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: there shall be no discharge of process waste water pollutants to navigable waters.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.54</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">Pretreatment standard</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6436, Feb. 11, 1975, as amended at 60 FR 33937, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.55</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties which may be discharged by a new source subject to the provisions of this subpart: There shall be no discharge of process waste water pollutants to navigable waters.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.56</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33937, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.57</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 406.52 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart F—Parboiled Rice Processing Subcategory</HD>
        <SECTION>
          <SECTNO>§ 406.60</SECTNO>
          <SUBJECT>Applicability; description of the parboiled rice processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the process in which rice is cleaned, cooked and dried before being milled.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.61</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term “rice” shall mean rice delivered to a plant before processing.</P>
          <P>(c) The abbreviation “cwt” shall mean hundred weight.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.62</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall <PRTPAGE P="83"/>achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of rice)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.42</ENT>
              <ENT>0.14</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.24</ENT>
              <ENT>.08</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per hundredweight of rice)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.042</ENT>
              <ENT>0.014</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.024</ENT>
              <ENT>.008</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 10513, Mar. 20, 1974, as amended at 60 FR 33937, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.63</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.64</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6436, Feb. 11, 1975, as amended at 60 FR 33937, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.65</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of rice)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.21</ENT>
              <ENT>0.07</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.09</ENT>
              <ENT>.03</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per hundredweight of rice)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.021</ENT>
              <ENT>0.007</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.009</ENT>
              <ENT>.003</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.66</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33937, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.67</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 406.62 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart G—Animal Feed Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 918, Jan. 3, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 406.70</SECTNO>
          <SUBJECT>Applicability; description of the animal feed subcategory.</SUBJECT>

          <P>The provisions of this subpart are applicable to discharges resulting from <PRTPAGE P="84"/>the manufacturing of animal feeds (formula feed concentrate) using primarily grain and grain by-products which may be supplemented by proteins, pharmaceuticals, vitamins or mineral additives.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.71</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart: The general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.72</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): There shall be no discharge of process waste water pollutants to navigable waters.</P>
          <CITA>[60 FR 33937, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.73</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.</SUBJECT>
          <P>The following limitations establish the quantity or quality of pollutants or pollutant properties, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: There shall be no discharge of process waste water pollutants to navigable waters.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.74</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.75</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties which may be discharged by a new source subject to the provisions of this subpart: There shall be no discharge of process waste water pollutants to navigable waters.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.76</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 918, Jan. 3, 1975, as amended at 60 FR 33937, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.77</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 406.72 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart H—Hot Cereal Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 918, Jan. 3, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 406.80</SECTNO>
          <SUBJECT>Applicability; description of the hot cereal subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the production of various breakfast cereals from grains, principally wheat and oats, requiring cooking prior to normal human consumption.</P>
        </SECTION>
        <SECTION>
          <PRTPAGE P="85"/>
          <SECTNO>§ 406.81</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) The general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">cereal</E> shall mean breakfast cereal.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.82</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): There shall be no discharge of process waste water pollutants to navigable waters.</P>
          <CITA>[60 FR 33937, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.83</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.</SUBJECT>
          <P>The following limitations establish the quantity or quality of pollutants or pollutant properties, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: There shall be no discharge of process waste water pollutants to navigable waters.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.84</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.85</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, which may be discharged by a new source subject to the provisions of this subpart: There shall be no discharge of process waste water pollutants to navigable waters.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.86</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 918, Jan. 3, 1975, as amended at 60 FR 33937, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.87</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 406.82 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart I—Ready-to-Eat Cereal Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 919, Jan. 3, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 406.90</SECTNO>
          <SUBJECT>Applicability; description of the ready-to-eat cereal subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of various grains and other materials (whole grain wheat, rice, corn grits, oat flour, sugar, and minor ingredients) to produce various breakfast cereals normally available for human consumption without cooking.</P>
        </SECTION>
        <SECTION>
          <PRTPAGE P="86"/>
          <SECTNO>§ 406.91</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) The general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">cereal</E> shall mean breakfast cereal.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.92</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of cereal product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.2</ENT>
              <ENT>0.40</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.2</ENT>
              <ENT>0.40</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of cereal product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.2</ENT>
              <ENT>0.40</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.2</ENT>
              <ENT>0.40</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 919, Jan. 3, 1975, as amended at 60 FR 33937, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§§ 406.93-406.94</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.95</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of cereal product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.60</ENT>
              <ENT>0.20</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.45</ENT>
              <ENT>0.15</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of cereal product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.60</ENT>
              <ENT>0.20</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.45</ENT>
              <ENT>0.15</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.96</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 919, Jan. 3, 1975, as amended at 60 FR 33937, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.97</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 406.92 of this subpart for the best practicable <PRTPAGE P="87"/>control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart J—Wheat Starch and Gluten Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 920, Jan. 3, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 406.100</SECTNO>
          <SUBJECT>Applicability; description of the wheat starch and gluten subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from those industrial operations utilizing wheat flour as a raw material for production of wheat starch and gluten (protein) components through conventional processes of physical separation and subsequent refinement.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.101</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart: The general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.102</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of raw material (wheat flour))</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>6.0</ENT>
              <ENT>2.0</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>6.0</ENT>
              <ENT>2.0</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of raw material (wheat flour))</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>6.0</ENT>
              <ENT>2.0</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>6.0</ENT>
              <ENT>2.0</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 920, Jan. 3, 1975, as amended at 60 FR 33937, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§§ 406.103-406.104</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.105</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of raw material (wheat flour))</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>3.0</ENT>
              <ENT>1.0</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>3.0</ENT>
              <ENT>1.0</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of raw material (wheat flour))</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>3.0</ENT>
              <ENT>1.0</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>3.0</ENT>
              <ENT>1.0</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.106</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <PRTPAGE P="88"/>
          <CITA>[40 FR 920, Jan. 3, 1975, as amended at 60 FR 33937, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 406.107</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 406.102 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
    </PART>
    <PART>
      <EAR>Pt. 407</EAR>
      <HD SOURCE="HED">PART 407—CANNED AND PRESERVED FRUITS AND VEGETABLES PROCESSING POINT SOURCE CATEGORY</HD>
      <CONTENTS>
        <SUBPART>
          <HD SOURCE="HED">Subpart A—Apple Juice Subcategory</HD>
          <SECHD>Sec.</SECHD>
          <SECTNO>407.10</SECTNO>
          <SUBJECT>Applicability; description of the apple juice subcategory.</SUBJECT>
          <SECTNO>407.11</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>407.12</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>407.13</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>407.14</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>407.15</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>407.16</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>407.17</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart B—Apple Products Subcategory</HD>
          <SECTNO>407.20</SECTNO>
          <SUBJECT>Applicability; description of the apple products subcategory.</SUBJECT>
          <SECTNO>407.21</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>407.22</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>407.23</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>407.24</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>407.25</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>407.26</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>407.27</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart C—Citrus Products Subcategory</HD>
          <SECTNO>407.30</SECTNO>
          <SUBJECT>Applicability; description of the citrus products subcategory.</SUBJECT>
          <SECTNO>407.31</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>407.32</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>407.33</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>407.34</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>407.35</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>407.36</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>407.37</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart D—Frozen Potato Products Subcategory</HD>
          <SECTNO>407.40</SECTNO>
          <SUBJECT>Applicability; description of the frozen potato products subcategory.</SUBJECT>
          <SECTNO>407.41</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>407.42</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>407.43</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>407.44</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>407.45</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>407.46</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>407.47</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart E—Dehydrated Potato Products Subcategory</HD>
          <SECTNO>407.50</SECTNO>
          <SUBJECT>Applicability; description of the dehydrated potato products subcategory.</SUBJECT>
          <SECTNO>407.51</SECTNO>
          <SUBJECT>Specialized definitions.<PRTPAGE P="89"/>
          </SUBJECT>
          <SECTNO>407.52</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>407.53</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>407.54</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>407.55</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>407.56</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>407.57</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart F—Canned and Preserved Fruits Subcategory</HD>
          <SECTNO>407.60</SECTNO>
          <SUBJECT>Applicability; description of the canned and preserved fruits subcategory.</SUBJECT>
          <SECTNO>407.61</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>407.62</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>407.63</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>407.64</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>407.65</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>407.66</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>407.67</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart G—Canned and Preserved Vegetables Subcategory</HD>
          <SECTNO>407.70</SECTNO>
          <SUBJECT>Applicability; description of the canned and preserved vegetables subcategory.</SUBJECT>
          <SECTNO>407.71</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>407.72</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>407.73</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>407.74</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>407.75</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>407.76</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>407.77</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart H—Canned and Miscellaneous Specialities Subcategory</HD>
          <SECTNO>407.80</SECTNO>
          <SUBJECT>Applicability; description of the canned and miscellaneous specialties subcategory.</SUBJECT>
          <SECTNO>407.81</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>407.82</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>407.83</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>407.84</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>407.85</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>407.86</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>407.87</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
      </CONTENTS>
      <AUTH>
        <HD SOURCE="HED">Authority:</HD>
        <P>Secs. 301, 304 (b) and (c), 306 (b) and (c), 307(c) of the Federal Water Pollution Control Act, as amended; 33 U.S.C. 1251, 1311, 1314 (b) and (c), 1316 (b) and (c), 1317(c); 86 Stat. 816 et seq., Pub. L. 92-500; 91 Stat. 1567, Pub. L. 95-217.</P>
      </AUTH>
      <SOURCE>
        <HD SOURCE="HED">Source:</HD>
        <P>39 FR 10864, Mar. 21, 1974, unless otherwise noted.</P>
      </SOURCE>
      <SUBPART>
        <HD SOURCE="HED">Subpart A—Apple Juice Subcategory</HD>
        <SECTION>
          <SECTNO>§ 407.10</SECTNO>
          <SUBJECT>Applicability; description of the apple juice subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of apples into apple juice or apple cider. When a plant is subject to effluent limitations covering more than one subcategory, the plant discharge limitation shall be set by proration limitations for each subcategory based on the total raw material covered by each subcategory.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.11</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.12</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point <PRTPAGE P="90"/>source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
          </P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.60</ENT>
              <ENT>0.30</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.80</ENT>
              <ENT>.40</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.60</ENT>
              <ENT>0.30</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.80</ENT>
              <ENT>.40</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 10864, Mar. 21, 1974, as amended at 60 FR 33938, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.13</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.14</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>

          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.
          </P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6436, Feb. 11, 1975, as amended at 60 FR 33938, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.15</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>

          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
          </P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of raw material</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.20</ENT>
              <ENT>0.10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.20</ENT>
              <ENT>.10</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.20</ENT>
              <ENT>0.10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.20</ENT>
              <ENT>.10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 10864, Mar. 21, 1974, as amended at 41 FR 48737, Nov. 5, 1976]</CITA>
          
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.16</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33938, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.17</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 407.12 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <PRTPAGE P="91"/>
        <HD SOURCE="HED">Subpart B—Apple Products Subcategory</HD>
        <SECTION>
          <SECTNO>§ 407.20</SECTNO>
          <SUBJECT>Applicability; description of the apple products subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of apples into apple products. The processing of apples into caustic peeled or dehydrated products is specifically excluded. When a plant is subject to effluent limitations covering more than one subcategory, the plant discharge limitation shall be set by proration limitations, for each subcategory based on the total raw material covered by each subcategory.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.21</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.22</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.10</ENT>
              <ENT>0.55</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.40</ENT>
              <ENT>.70</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of raw material</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.10</ENT>
              <ENT>0.55</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.40</ENT>
              <ENT>.70</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 10864, Mar. 21, 1974, as amended at 60 FR 33938, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.23</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.24</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6437, Feb. 11, 1975, as amended at 60 FR 33938, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.25</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.20</ENT>
              <ENT>0.10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.20</ENT>
              <ENT>.10</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.20</ENT>
              <ENT>0.10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.20</ENT>
              <ENT>.10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 10864, Mar. 21, 1974, as amended at 41 FR 48737, Nov. 5, 1976]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.26</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>

          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned <PRTPAGE P="92"/>treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33938, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.27</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 407.22 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart C—Citrus Products Subcategory</HD>
        <SECTION>
          <SECTNO>§ 407.30</SECTNO>
          <SUBJECT>Applicability; description of the citrus products subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of citrus into citrus products. When a plant is subject to effluent limitations covering more than one subcategory, the plant discharge limitation shall be set by proration limitations for each subcategory based on raw material covered by each subcategory.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.31</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.32</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.80</ENT>
              <ENT>0.40</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.70</ENT>
              <ENT>0.85</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.80</ENT>
              <ENT>0.40</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.70</ENT>
              <ENT>0.85</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 10864, Mar. 21, 1974, as amended at 60 FR 33938, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.33</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.34</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6437, Feb. 11, 1975, as amended at 60 FR 33938, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.35</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>

          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:<PRTPAGE P="93"/>
          </P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.14</ENT>
              <ENT>0.07</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.20</ENT>
              <ENT>.10</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.14</ENT>
              <ENT>0.07</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.20</ENT>
              <ENT>.10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 10864, Mar. 21, 1974, as amended at 41 FR 48737, Nov. 5, 1976]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.36</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33939, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.37</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 407.32 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart D—Frozen Potato Products Subcategory</HD>
        <SECTION>
          <SECTNO>§ 407.40</SECTNO>
          <SUBJECT>Applicability; description of the frozen potato products subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of white potatoes into frozen potato products. When a plant is subject to effluent limitations covering more than one subcategory, the plant discharge limitation shall be set by proration limitations for each subcategory based on the total raw material covered by each subcategory.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.41</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.42</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>2.80</ENT>
              <ENT>1.40</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.80</ENT>
              <ENT>1.40</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>2.80</ENT>
              <ENT>1.40</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.80</ENT>
              <ENT>1.40</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 10864, Mar. 21, 1974, as amended at 60 FR 33939, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <PRTPAGE P="94"/>
          <SECTNO>§ 407.43</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.44</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6437, Feb. 11, 1975, as amended at 60 FR 33939, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.45</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.34</ENT>
              <ENT>0.17</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.10</ENT>
              <ENT>.55</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.34</ENT>
              <ENT>0.17</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.10</ENT>
              <ENT>.55</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 10864, Mar. 21, 1974, as amended at 41 FR 48737, Nov. 5, 1976]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.46</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33939, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.47</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 407.42 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart E—Dehydrated Potato Products Subcategory</HD>
        <SECTION>
          <SECTNO>§ 407.50</SECTNO>
          <SUBJECT>Applicability; description of the dehydrated potato products subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of white potatoes into dehydrated potato products. When a plant is subject to effluent limitations covering more than one subcategory, the plant discharge limitation shall be set by proration limitations for each subcategory based on the total raw material covered by each subcategory.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.51</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) [Reserved]</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.52</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall <PRTPAGE P="95"/>achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>2.40</ENT>
              <ENT>1.20</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.80</ENT>
              <ENT>1.40</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>2.40</ENT>
              <ENT>1.20</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.80</ENT>
              <ENT>1.40</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 10864, Mar. 21, 1974, as amended at 60 FR 33939, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.53</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.54</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6437, Feb. 11, 1975, as amended at 60 FR 33939, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.55</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.34</ENT>
              <ENT>0.17</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.10</ENT>
              <ENT>.55</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of raw material)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.34</ENT>
              <ENT>0.17</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.10</ENT>
              <ENT>.55</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 10864, Mar. 21, 1974, as amended at 41 FR 48737, Nov. 5, 1976]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.56</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33939, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.57</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 407.52 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart F—Canned and Preserved Fruits Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>41 FR 16277, Apr. 16, 1976, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <PRTPAGE P="96"/>
          <SECTNO>§ 407.60</SECTNO>
          <SUBJECT>Applicability; description of the canned and preserved fruits subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of the following fruit products: Apricots; caneberries; sweet, sour and brined cherries; cranberries; dried fruit; grape juice canning and pressing; olives; peaches; pears; fresh and processed pickles, and pickle salting stations; pineapples; plums; raisins; strawberries; and tomatoes. When a plant is subject to effluent limitations covering more than one commodity or subcategory, the plant discharge limitation shall be set by proration of limitations for each subcategory or commodity based on the total production covered by each commodity or subcategory.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.61</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">apricots</E> shall include the processing of apricots into the following product styles: Canned and frozen, pitted and unpitted, peeled and unpeeled, whole, halves, slices, nectar, and concentrate.</P>
          <P>(c) The term <E T="03">caneberries</E> shall include the processing of the following berries: Canned and frozen blackberries, blueberries, boysenberries, currants, gooseberries, loganberries, ollalieberries, raspberries, and any other similar cane or bushberry but not strawberries or cranberries.</P>
          <P>(d) The term <E T="03">cherries, sweet</E> shall include the processing of all sweet varieties of cherries into the following products styles: Frozen and canned, pitted and unpitted, whole, halves, juice and concentrate.</P>
          <P>(e) The term <E T="03">cherries, sour</E> shall include the processing of all sour varieties of cherries into the following products styles: Frozen and canned, pitted and unpitted, whole, halves, juice and concentrate.</P>
          <P>(f) The term <E T="03">cherries, brined</E> shall include the processing of all varieties of cherries into the following brined product styles: Canned, bottled and bulk, sweet and sour, pitted and unpitted, bleached, sweetened, colored and flavored, whole, halved and chopped.</P>
          <P>(g) The term <E T="03">cranberries</E> shall mean the processing of cranberries into the following product styles: Canned, bottled, and frozen, whole, sauce, jelly, juice and concentrate.</P>
          <P>(h) The term <E T="03">dried fruit</E> shall mean the processing of various fruits into the following products styles: Air, vacuum, and freeze dried, pitted and unpitted, blanched and unblanched, whole, halves, slices and other similar styles of apples, apricots, figs, peaches, pears, prunes, canned extracted prune juice and pulp from rehydrated and cooked dehydrated prunes; but not including dates or raisins.</P>
          <P>(i) The term <E T="03">grape juice canning</E> shall mean the processing of grape juice into the following products and product styles: Canned and frozen, fresh and stored, natural grape juice for the manufacture of juices, drinks, concentrates, jams, jellies, and other related finished products but not wine or other spirits. In terms of raw material processed 1000 kg (1000 lb) of grapes are equivalent to 834 liters (100 gallons) of grape juice.</P>
          <P>(j) The term <E T="03">grape pressing</E> shall mean the washing and subsequent handling including pressing, heating, and filtration of natural juice from all varieties of grapes for the purpose of manufacturing juice, drink, concentrate, and jelly but not wine or other spirits. In terms of raw material processed 1000 kg (1000 lb) of grapes are equivalent to 834 liters (100 gallons) of grape juice.</P>
          <P>(k) The term <E T="03">olives</E> shall mean the processing of olives into the following product styles: Canned, all varieties, fresh and stored, green ripe, black ripe, spanish, sicilian, and any other styles to which spices, acids, and flavorings may have been added.</P>
          <P>(l) The term <E T="03">peaches</E> shall mean the processing of peaches into the following product styles: Canned or frozen, all varieties, peeled, pitted and unpitted, whole, halves, sliced, diced, and any other cuts, nectar, and concentrate but not dehydrated.</P>
          <P>(m) The term <E T="03">pears</E> shall mean the processing of pears into the following product styles: Canned, peeled, halved, <PRTPAGE P="97"/>sliced, diced, and any other cuts, nectar and concentrate but not dehydrated.</P>
          <P>(n) The term <E T="03">pickles, fresh</E> shall mean the processing of fresh cucumbers and other vegetables, all varieties, all sizes from whole to relish, all styles, cured after packing.</P>
          <P>(o) The term <E T="03">pickles processed</E> shall mean the processing of pickles, cucumbers and other vegetables, all varieties, sizes and types, made after fermentation and storage.</P>
          <P>(p) The term <E T="03">pickles, salt stations</E> shall mean the handling and subsequent preserving of cucumbers and other vegetables at salting stations or tankyards, by salt and other chemical additions necessary to achieve proper fermentation for the packing of processed pickle products. Limitations include allowances for the discharge of spent brine, tank wash, tank soak, and cucumber wash waters. At locations where both salt station and process pack operations (§ 407.61(o)) occur, additive allowances shall be made for both of these sources in formulation of effluent limitations. The effluent limitations are to be calculated based upon the total annual weight (1000 lb, kkg) of raw product processed at each of the salt station and process pack operations. Allowances for contaminated stormwater runoff should be considered in NPDES permit formulation on a case-by-case basis.</P>
          <P>(q) The term <E T="03">pineapples</E> shall mean the processing of pineapple into the following product styles: Canned, peeled, sliced, chunk, tidbit, diced, crushed, and any other related piece size, juice and concentrate. It also specifically includes the on-site production of by-products such as alcohol, sugar or animal feed.</P>
          <P>(r) The term <E T="03">plums</E> shall mean the processing of plums into the following product styles: Canned and frozen, pitted and unpitted, peeled and unpeeled, blanched and unblanched, whole, halved, and other piece size.</P>
          <P>(s) The term <E T="03">raisins</E> shall mean the production of raisins from the following products: Dried grapes, all varieties, bleached and unbleached, which have been cleaned and washed prior to packaging.</P>
          <P>(t) The term <E T="03">strawberries</E> shall mean the processing of strawberries into the following product styles: Canned and frozen, whole, sliced, and pureed.</P>
          <P>(u) The term <E T="03">tomatoes</E> shall mean the processing of tomatoes into canned, peeled, whole, stewed, and related piece sizes; and processing of tomatoes into the following products and product styles: Canned, peeled and unpeeled paste, concentrate, puree, sauce, juice, catsup and other similar formulated items requiring various other pre-processed food ingredients.</P>
          <P>(v) The term <E T="03">medium</E> shall mean a point source that processes a total annual raw material production of fruits, vegetables, specialties and other products that is between 1,816 kkg (2,000 tons) per year and 9,080 kkg (10,000 tons) per year.</P>
          <P>(w) The term <E T="03">large</E> shall mean a point source that processes a total annual raw material production of fruits, vegetables, specialties and other products that exceeds 9,080 kkg (10,000 tons) per year.</P>
          <P>(x) The term <E T="03">annual average</E> shall mean the maximum allowable discharge of BOD<E T="03">5</E> or TSS as calculated by multiplying the total mass (kkg or 1000 lb) of each raw commodity processed for the entire processing season or calendar year by the applicable annual average limitation.</P>
          <P>(y) The terms <E T="03">maximum for any one day</E> and <E T="03">average of daily values for thirty consecutive days</E> shall be based on the daily average mass of material processed during the peak thirty consecutive day production period.</P>
          <CITA>[41 FR 16277, Apr. 16, 1976, as amended at 44 FR 22464, Apr. 16, 1979]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.62</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) The following limitations establish the quantity of BOD<E T="03">5</E> controlled by <PRTPAGE P="98"/>this section, which may be discharged by a “medium” or “large” existing point source subject to the provisions of this subpart after application of the best practicable control technology currently available. Any fruit processing plant which continuously or intermittently discharges process waste water during the processing season shall meet the annual average, maximum thirty day average, and maximum day BOD<E T="03">5</E> limitations. Fruit processing plants employing long term waste stabilization, where all or a portion of the process waste water discharge is stored for the entire processing season and released at a controlled rate with State approval, shall meet only the annual average BOD<E T="03">5</E> limitations.</P>
          <GPOTABLE CDEF="s25,7,12,7" COLS="4" OPTS="L2">
            <TDESC>[Metric units, kg/kkg of raw material; English units, lb/1,000 lb of raw material]</TDESC>
            <BOXHD>
              <CHED H="1">Commodity (fruits)</CHED>
              <CHED H="1">BOD<E T="03">5</E> effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
              <CHED H="2">Annual average shall not exceed—</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">Apricots</ENT>
              <ENT>3.00</ENT>
              <ENT>1.81</ENT>
              <ENT>1.26</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Caneberries</ENT>
              <ENT>0.77</ENT>
              <ENT>0.46</ENT>
              <ENT>0.32</ENT>
            </ROW>
            <ROW>
              <ENT I="11">Cherries:</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Brined</ENT>
              <ENT>2.87</ENT>
              <ENT>1.78</ENT>
              <ENT>1.28</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Sour</ENT>
              <ENT>1.77</ENT>
              <ENT>1.11</ENT>
              <ENT>0.81</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Sweet</ENT>
              <ENT>1.12</ENT>
              <ENT>0.69</ENT>
              <ENT>0.49</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Cranberries</ENT>
              <ENT>1.71</ENT>
              <ENT>1.03</ENT>
              <ENT>0.73</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Dried fruit</ENT>
              <ENT>1.86</ENT>
              <ENT>1.13</ENT>
              <ENT>0.80</ENT>
            </ROW>
            <ROW>
              <ENT I="11">Grape juice:</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Canning</ENT>
              <ENT>1.10</ENT>
              <ENT>0.69</ENT>
              <ENT>0.51</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Pressing</ENT>
              <ENT>0.22</ENT>
              <ENT>0.14</ENT>
              <ENT>0.10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Olives</ENT>
              <ENT>5.44</ENT>
              <ENT>3.34</ENT>
              <ENT>2.39</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Peaches</ENT>
              <ENT>1.51</ENT>
              <ENT>0.93</ENT>
              <ENT>0.67</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Pears</ENT>
              <ENT>1.77</ENT>
              <ENT>1.12</ENT>
              <ENT>0.83</ENT>
            </ROW>
            <ROW>
              <ENT I="11">Pickles:</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Fresh pack</ENT>
              <ENT>1.22</ENT>
              <ENT>0.75</ENT>
              <ENT>0.53</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Process pack</ENT>
              <ENT>1.45</ENT>
              <ENT>0.92</ENT>
              <ENT>0.68</ENT>
            </ROW>
            <ROW>
              <ENT I="03">Salt stations</ENT>
              <ENT>0.25</ENT>
              <ENT>0.18</ENT>
              <ENT>0.15</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Pineapples</ENT>
              <ENT>2.13</ENT>
              <ENT>1.33</ENT>
              <ENT>0.96</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Plums</ENT>
              <ENT>0.69</ENT>
              <ENT>0.42</ENT>
              <ENT>0.29</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Raisins</ENT>
              <ENT>0.43</ENT>
              <ENT>0.28</ENT>
              <ENT>0.21</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Strawberries</ENT>
              <ENT>1.79</ENT>
              <ENT>1.06</ENT>
              <ENT>0.74</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Tomatoes</ENT>
              <ENT>1.21</ENT>
              <ENT>0.71</ENT>
              <ENT>0.94</ENT>
            </ROW>
          </GPOTABLE>
          <P>(b) The following limitations establish the quantity of TSS controlled by this section, which may be discharged by a “medium” or “large” existing point source subject to the provisions of this subpart after application of the best practicable control technology currently available. Any fruit processing plant which continuously or intermittently discharges process waste water during the processing season shall meet the annual average, maximum thirty day average, and maximum day TSS limitations. Fruit processing plants employing long term waste stabilization, where all or a portion of the process waste water discharge is stored for the entire processing season and released at a controlled rate with state approval, shall meet only the annual average TSS limitations.</P>
          <GPOTABLE CDEF="s25,7,12,7" COLS="4" OPTS="L2">
            <TDESC>[Metric units, kg/kkg of raw material; English units, lb/1,000 lb of raw material]</TDESC>
            <BOXHD>
              <CHED H="1">Commodity (fruits)</CHED>
              <CHED H="1">TSS effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
              <CHED H="2">Annual average shall not exceed—</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">Apricots</ENT>
              <ENT>5.36</ENT>
              <ENT>3.74</ENT>
              <ENT>2.33</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Caneberries</ENT>
              <ENT>1.38</ENT>
              <ENT>0.95</ENT>
              <ENT>0.58</ENT>
            </ROW>
            <ROW>
              <ENT I="11">Cherries:</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Brined</ENT>
              <ENT>5.18</ENT>
              <ENT>3.68</ENT>
              <ENT>2.38</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Sour</ENT>
              <ENT>3.20</ENT>
              <ENT>2.30</ENT>
              <ENT>1.52</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Sweet</ENT>
              <ENT>2.01</ENT>
              <ENT>1.43</ENT>
              <ENT>0.92</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Cranberries</ENT>
              <ENT>3.06</ENT>
              <ENT>2.14</ENT>
              <ENT>1.34</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Dried fruit</ENT>
              <ENT>3.34</ENT>
              <ENT>2.34</ENT>
              <ENT>1.48</ENT>
            </ROW>
            <ROW>
              <ENT I="11">Grape juice:</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Canning</ENT>
              <ENT>1.99</ENT>
              <ENT>1.44</ENT>
              <ENT>0.96</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Pressing</ENT>
              <ENT>0.40</ENT>
              <ENT>0.29</ENT>
              <ENT>0.18</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Olives</ENT>
              <ENT>9.79</ENT>
              <ENT>6.92</ENT>
              <ENT>4.44</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Peaches</ENT>
              <ENT>2.72</ENT>
              <ENT>1.93</ENT>
              <ENT>1.26</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Pears</ENT>
              <ENT>3.21</ENT>
              <ENT>2.32</ENT>
              <ENT>1.55</ENT>
            </ROW>
            <ROW>
              <ENT I="11">Pickles:</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Fresh pack</ENT>
              <ENT>2.19</ENT>
              <ENT>1.54</ENT>
              <ENT>0.99</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Process pack</ENT>
              <ENT>2.63</ENT>
              <ENT>1.91</ENT>
              <ENT>1.28</ENT>
            </ROW>
            <ROW>
              <ENT I="03">Salt stations</ENT>
              <ENT>0.42</ENT>
              <ENT>0.33</ENT>
              <ENT>0.25</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Pineapples</ENT>
              <ENT>3.85</ENT>
              <ENT>2.76</ENT>
              <ENT>1.81</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Plums</ENT>
              <ENT>1.24</ENT>
              <ENT>0.87</ENT>
              <ENT>0.54</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Raisins</ENT>
              <ENT>0.78</ENT>
              <ENT>0.57</ENT>
              <ENT>0.39</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Strawberries</ENT>
              <ENT>3.19</ENT>
              <ENT>2.20</ENT>
              <ENT>1.35</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Tomatoes</ENT>
              <ENT>2.15</ENT>
              <ENT>1.48</ENT>
              <ENT>0.90</ENT>
            </ROW>
          </GPOTABLE>
          <P>(c) The following limitations establish the quality of pH controlled by this section, which may be discharged by a “medium” or “large” existing point source subject to the provisions of this subpart after application of the best practicable control technology currently available.</P>
          <GPOTABLE CDEF="s40,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>At all times within the range 6.0 to 9.5.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[41 FR 16277, Apr. 16, 1976, as amended at 44 FR 22464, Apr. 16, 1979; 60 FR 33939, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <PRTPAGE P="99"/>
          <SECTNO>§ 407.63</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.64</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by any existing point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[41 FR 16277, Apr. 16, 1976, as amended at 60 FR 33939, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.65</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.66</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[41 FR 16277, Apr. 16, 1976, as amended at 60 FR 33939, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.67</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 407.62 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart G—Canned and Preserved Vegetables Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>41 FR 16281, Apr. 16, 1976, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 407.70</SECTNO>
          <SUBJECT>Applicability; description of the canned and preserved vegetables subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of the following vegetable products: Beets; broccoli; carrots; canned and frozen corn; dehydrated onions and garlic; dehydrated vegetables; dry beans; lima beans; mushrooms; canned onions; peas; sauerkraut canning and cutting; snap beans; spinach; squash; and canned potatoes. When a plant is subject to effluent limitations covering more than one commodity or subcategory, the plant discharge limitations shall be set by proration of limitations for each subcategory or commodity based on the total production covered by each commodity or subcategory.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.71</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">beets</E> shall include the processing of beets into the following product styles: Canned and peeled, whole, sliced, diced, French style, sections, irregular, and other cuts but not dehydrated beets.</P>
          <P>(c) The term <E T="03">broccoli</E> shall include the processing of broccoli into the following product styles: Frozen, chopped, spears, and miscellaneous cuts.</P>
          <P>(d) The term <E T="03">carrots</E> shall include the processing of carrots into the following product styles: Canned and frozen, peeled, whole, sliced, diced, nuggets, <PRTPAGE P="100"/>crinkle cut, julienne, shoestrings, chunks, chips and other irregular cuts, and juices but not dehydrated carrots.</P>
          <P>(e) The term <E T="03">corn, canned</E> shall mean the processing of corn into the following product styles: Canned, yellow and white, whole kernel, cream style, and on-the-cob.</P>
          <P>(f) The term <E T="03">corn, frozen</E> shall mean the processing of corn into the following product styles: Frozen, yellow and white, whole kernel and whole cob.</P>
          <P>(g) The term <E T="03">dehydrated onions and garlic</E> shall mean the processing of dehydrated onions and garlic into the following product styles: Air, vacuum, and freeze dried, all varieties, diced, strips, and other piece sizes ranging from large sliced to powder but not including green onions, chives, or leeks.</P>
          <P>(h) The term <E T="03">dehydrated vegetables</E> shall mean the processing of dehydrated vegetables in the following product styles: Air, vacuum and freeze dried, blanched and unblanched, peeled and unpeeled, beets, bell peppers, cabbage, carrots, celery, chili pepper, horseradish, turnips, parsnips, parsley, asparagus, tomatoes, green beans, corn, spinach, green onion tops, chives, leeks, whole, diced, and any other piece size ranging from sliced to powder.</P>
          <P>(i) The term <E T="03">dry beans</E> shall mean the production of canned pinto, kidney, navy, great northern, red, pink or related type, with and without formulated sauces, meats and gravies.</P>
          <P>(j) The term <E T="03">lima beans</E> shall mean the processing of lima beans into the following product styles: Canned and frozen, green and white, all varieties and sizes.</P>
          <P>(k) The term <E T="03">mushrooms</E> shall mean the processing of mushrooms into the following product styles: Canned, frozen, dehydrated, all varieties, shapes and sizes.</P>
          <P>(l) The term <E T="03">canned onions</E> shall mean the processing of onions into the following product styles: Canned, frozen, and fried (canned), peeled, whole, sliced, and any other piece size but not including frozen, battered onion rings or dehydrated onions.</P>
          <P>(m) The term <E T="03">peas</E> shall mean the processing of peas into the following product styles: Canned and frozen, all varieties and sizes, whole.</P>
          <P>(n) The term <E T="03">squash</E> shall include the processing of pumpkin and squash into canned and frozen styles.</P>
          <P>(o) The term <E T="03">sauerkraut cutting</E> shall mean the trimming, cutting, and subsequent preparatory handling of cabbage necessary for and including brining and fermentation, and subsequent tank soaking.</P>
          <P>(p) The term <E T="03">sauerkraut canning</E> shall mean the draining and subsequent filling and canning of fermented cabbage and juice.</P>
          <P>(q) The term <E T="03">snap beans</E> shall mean the processing of snap beans into the following product styles: Canned and frozen green, Italian, wax, string, bush, and other related varieties, whole, French, fancy, Extra Standard, Standard, and other cuts.</P>
          <P>(r) The term <E T="03">spinach</E> shall mean the processing of spinach and leafy greens into the following product styles: Canned or frozen, whole leaf, chopped, and other related cuts.</P>
          <P>(s) The term <E T="03">potatoes</E> shall mean the processing of sweet potatoes into the following product styles: Canned, peeled, solid, syrup, and vacuum packed. The following white potato product styles are also included: Canned, peeled, white, all varieties, whole and sliced.</P>
          <P>(t) The term <E T="03">medium</E> shall mean a point source that processes a total annual raw material production of fruits, vegetables, specialties and other products that is between 1,816 kkg (2,000 tons) per year and 9,080 kkg (10,000 tons) per year.</P>
          <P>(u) The term <E T="03">large</E> shall mean a point source that processes a total annual raw material production of fruits, vegetables, specialties and other products that exceeds 9,080 kkg (10,000 tons) per year.</P>
          <P>(v) The term <E T="03">annual average</E> shall mean the maximum allowable discharge of BOD<E T="03">5</E> or TSS as calculated by multiplying the total mass (kkg or 1000 lb) of each raw commodity processed for the entire processing season or calendar year by the applicable annual average limitation.</P>
          <P>(w) The terms <E T="03">maximum for any one day</E> and <E T="03">average of daily values for thirty consecutive days</E> shall be based on the daily average mass of raw material <PRTPAGE P="101"/>processed during the peak thirty consecutive day production period.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.72</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) The following limitations establish the quantity of BOD<E T="03">5</E> controlled by this section, which may be discharged by a “medium” or “large” existing point source subject to the provisions of this subpart after application of the best practicable control technology currently available. Any vegetable processing plant which continuously or intermittently discharges process waste water during the processing season shall meet the annual average, maximum thirty day average, and maximum day BOD<E T="03">5</E> limitations. Vegetable processing plants employing long term waste stabilization, where all or a portion of the process waste water discharge is stored for the entire processing season and released at a controlled rate with State approval, shall meet only the annual average BOD<E T="03">5</E> limitations. The effluent limitations do not apply to single-commodity 100 percent canned corn processing plants of all sizes, and multi-commodity 100 percent frozen vegetable processing plants with total annual raw material production less than 7,264 kkg (8,000 tons) per year.</P>
          <GPOTABLE CDEF="s25,7,12,7" COLS="4" OPTS="L2">
            <TDESC>[Metric units, kg/kkg of raw material; English units, lb/1,000 lb of raw material]</TDESC>
            <BOXHD>
              <CHED H="1">Commodity (vegetables)</CHED>
              <CHED H="1">BOD<E T="03">5</E> effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
              <CHED H="2">Annual average shall not exceed—</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">Beets</ENT>
              <ENT>1.01</ENT>
              <ENT>0.71</ENT>
              <ENT>0.57</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Broccoli</ENT>
              <ENT>3.83</ENT>
              <ENT>2.21</ENT>
              <ENT>1.47</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Carrots</ENT>
              <ENT>1.76</ENT>
              <ENT>1.11</ENT>
              <ENT>0.82</ENT>
            </ROW>
            <ROW>
              <ENT I="11">Corn:</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Canned</ENT>
              <ENT>0.71</ENT>
              <ENT>0.48</ENT>
              <ENT>0.38</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Frozen</ENT>
              <ENT>1.45</ENT>
              <ENT>0.84</ENT>
              <ENT>0.56</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Dehydrated onion/garlic</ENT>
              <ENT>2.45</ENT>
              <ENT>1.46</ENT>
              <ENT>0.98</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Dehydrated vegetables</ENT>
              <ENT>2.98</ENT>
              <ENT>1.76</ENT>
              <ENT>1.21</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Dry beans</ENT>
              <ENT>2.50</ENT>
              <ENT>1.51</ENT>
              <ENT>1.07</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Lima beans</ENT>
              <ENT>3.68</ENT>
              <ENT>2.19</ENT>
              <ENT>1.51</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Mushrooms</ENT>
              <ENT>3.01</ENT>
              <ENT>1.78</ENT>
              <ENT>1.22</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Onions (canned)</ENT>
              <ENT>3.09</ENT>
              <ENT>1.83</ENT>
              <ENT>1.25</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Peas</ENT>
              <ENT>2.42</ENT>
              <ENT>1.50</ENT>
              <ENT>1.08</ENT>
            </ROW>
            <ROW>
              <ENT I="11">Sauerkraut:</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Canning</ENT>
              <ENT>0.50</ENT>
              <ENT>0.30</ENT>
              <ENT>0.21</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Cutting</ENT>
              <ENT>0.08</ENT>
              <ENT>0.05</ENT>
              <ENT>0.04</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Snap beans</ENT>
              <ENT>1.51</ENT>
              <ENT>0.87</ENT>
              <ENT>0.58</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Spinach</ENT>
              <ENT>2.37</ENT>
              <ENT>1.36</ENT>
              <ENT>0.91</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Squash</ENT>
              <ENT>0.90</ENT>
              <ENT>0.59</ENT>
              <ENT>0.46</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Potatoes</ENT>
              <ENT>0.90</ENT>
              <ENT>0.66</ENT>
              <ENT>0.55</ENT>
            </ROW>
          </GPOTABLE>
          <P>(b) The following limitations establish the quantity of TSS controlled by the section, which may be discharged by a “medium” or “large” existing point source subject to the provisions of this subpart after application of the best practicable control technology currently available. Any vegetable processing plant which continuously or intermittently discharges process waste water during the processing season shall meet the annual average, maximum thirty day average, and maximum day TSS limitations. Vegetable processing plants employing long term waste stabilization, where all or a portion of the process waste water discharge is stored for the entire processing season and released at a controlled rate with state approval, shall meet only the annual average TSS limitations. The effluent limitations do not apply to single-commodity 100 percent canned corn processing plants of all sizes, and multi-commodity 100 percent frozen vegetable processing plants with total annual raw material production less than 7,264 kkg (8,000 tons) per year.</P>
          <GPOTABLE CDEF="s25,7,12,7" COLS="4" OPTS="L2">
            <TDESC>[Metric units, kg/kkg of raw material; English units, lb/1,000 lb of raw material]</TDESC>
            <BOXHD>
              <CHED H="1">Commodity (vegetables)</CHED>
              <CHED H="1">TSS <E T="01">effluent limitations</E>
              </CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
              <CHED H="2">Annual average shall not exceed—</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">Beets</ENT>
              <ENT>1.88</ENT>
              <ENT>1.47</ENT>
              <ENT>1.12</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Broccoli</ENT>
              <ENT>6.78</ENT>
              <ENT>4.57</ENT>
              <ENT>2.65</ENT>
            </ROW>
            <ROW>
              <PRTPAGE P="102"/>
              <ENT I="01">Carrots</ENT>
              <ENT>3.19</ENT>
              <ENT>2.30</ENT>
              <ENT>1.54</ENT>
            </ROW>
            <ROW>
              <ENT I="11">Corn:</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Canned</ENT>
              <ENT>1.32</ENT>
              <ENT>1.00</ENT>
              <ENT>0.73</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Frozen</ENT>
              <ENT>3.13</ENT>
              <ENT>2.30</ENT>
              <ENT>1.57</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Dehydrated onion/garlic</ENT>
              <ENT>4.49</ENT>
              <ENT>3.02</ENT>
              <ENT>1.76</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Dehydrated vegetables</ENT>
              <ENT>5.30</ENT>
              <ENT>3.65</ENT>
              <ENT>2.21</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Dry beans</ENT>
              <ENT>4.48</ENT>
              <ENT>3.13</ENT>
              <ENT>1.97</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Lima beans</ENT>
              <ENT>6.56</ENT>
              <ENT>4.53</ENT>
              <ENT>2.76</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Mushrooms</ENT>
              <ENT>5.36</ENT>
              <ENT>3.68</ENT>
              <ENT>2.22</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Onions (canned)</ENT>
              <ENT>5.51</ENT>
              <ENT>3.78</ENT>
              <ENT>2.28</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Peas</ENT>
              <ENT>4.36</ENT>
              <ENT>3.11</ENT>
              <ENT>2.02</ENT>
            </ROW>
          </GPOTABLE>
          <GPOTABLE CDEF="s25,7,12,7" COLS="4" OPTS="L2(4,4,4)">
            <TDESC>[Metric units, kg/kkg of raw material; English units, lb/1,000 lb of raw material]</TDESC>
            <BOXHD>
              <CHED H="1">Commodity (vegetables)</CHED>
              <CHED H="1">TSS <E T="01">effluent limitations</E>
              </CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
              <CHED H="2">Annual average shall not exceed—</CHED>
            </BOXHD>
            <ROW>
              <ENT I="11">Sauerkraut:</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Canning</ENT>
              <ENT>0.89</ENT>
              <ENT>0.63</ENT>
              <ENT>0.40</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Cutting</ENT>
              <ENT>0.14</ENT>
              <ENT>0.11</ENT>
              <ENT>0.08</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Snap beans</ENT>
              <ENT>2.67</ENT>
              <ENT>1.80</ENT>
              <ENT>1.04</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Spinach</ENT>
              <ENT>4.19</ENT>
              <ENT>2.81</ENT>
              <ENT>1.64</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Squash</ENT>
              <ENT>1.64</ENT>
              <ENT>1.23</ENT>
              <ENT>0.87</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Potatoes</ENT>
              <ENT>1.69</ENT>
              <ENT>1.37</ENT>
              <ENT>1.09</ENT>
            </ROW>
          </GPOTABLE>
          <P>(c) The following limitations establish the quality of pH controlled by this section, which may be discharged by a “medium” or “large” existing point source subject to the provisions of this subpart after application of the best practicable control technology currently available. The effluent limitations do not apply to single-commodity 100 percent canned corn processing plants of all sizes, and multi-commodity 100 percent frozen vegetable processing plants with total annual raw material production less than 7,264 kkg (8,000 tons) per year.</P>
          <GPOTABLE CDEF="s40,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>At all times within the range 6.0 to 9.5.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[41 FR 16281, Apr. 16, 1976, as amended at 60 FR 33939, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.73</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.74</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by any existing point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[41 FR 16281, Apr. 16, 1976, as amended at 60 FR 33939, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.75</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.76</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[41 FR 16281, Apr. 16, 1976, as amended at 60 FR 33939, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.77</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall <PRTPAGE P="103"/>achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 407.72 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart H—Canned and Miscellaneous Specialties Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>41 FR 16284, Apr. 16, 1976, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 407.80</SECTNO>
          <SUBJECT>Applicability; description of the canned and miscellaneous specialties subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of the following specialty products: Added ingredients; baby food; corn, potato, and tortilla chips; ethnic foods; jams and jellies; mayonnaise and dressings; soups; and tomato-starch-cheese canned specialties. When a plant is subject to effluent limitations covering more than one commodity or subcategory, the plant discharge limitations shall be set by proration of limitations for each subcategory or commodity based on the total production covered by each commodity or subcategory.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.81</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">added ingredients</E> shall mean the prepared sauces (prepared from items such as dairy products, starches, sugar, tomato sauce and concentrate, spices, and other related preprocessed ingredients) which are added during the canning and freezing of fruits and vegetables.</P>
          <P>(c) The term <E T="03">baby foods</E> shall mean the processing of canned fresh fruits and vegetables, meats, eggs, fruit juices, cereal, formulated entrees, desserts and snacks using fresh, pre-processed, or any combination of these and other food ingredients necessary for the production of infant foods.</P>
          <P>(d) The term <E T="03">chips, potato</E> shall mean the processing of fried chips, made from fresh or stored white potatoes, all varieties. In terms of finished potato chips, 1 kg (lb) of finished product is equivalent to 4 kg (lb) of raw material.</P>
          <P>(e) The term <E T="03">chips, corn</E> shall mean the processing of fried corn, made by soaking, rinsing, milling and extruding into a fryer without toasting. In terms of finished corn chips, 1 kg (lb) of finished product is equivalent to 0.9 kg (lb) of raw material.</P>
          <P>(f) The term <E T="03">chips, tortilla</E> shall mean the processing of fried corn, made by soaking, rinsing, milling, rolling into sheets, toasting and frying. In terms of finished tortilla chips, 1 kg (lb) of finished product is equivalent to 0.9 kg (lb) of raw material.</P>
          <P>(g) The term <E T="03">ethnic foods</E> shall mean the production of canned and frozen Chinese and Mexican specialties utilizing fresh and pre-processed bean sprouts, bamboo shoots, water chestnuts, celery, cactus, tomatoes, and other similar vegetables necessary for the production of the various characteristic product styles.</P>
          <P>(h) The term <E T="03">jams and jellies</E> shall include the production of jams, jellies and preserves defined as follows: The combination of fruit and fruit concentrate, sugar, pectin, and other additives in an acidic medium resulting in a gelatinized and thickened finished product.</P>
          <P>(i) The term <E T="03">mayonnaise and salad dressings</E> shall be defined as the emulsified and non-emulsified semisolid food prepared from the combining of edible vegetable oil with acidifying, and egg yolk containing ingredients, or gum and starch combinations to which certain colorings, spices, and flavorings have been added.</P>
          <P>(j) The term <E T="03">soups</E> shall mean the combination of various fresh and pre-processed meats, fish, dairy products, eggs, flours, starches, vegetables, spices, and other similar raw ingredients into a variety of finished mixes and styles but not including dehydrated soups.<PRTPAGE P="104"/>
          </P>
          <P>(k) The term <E T="03">tomato-starch-cheese canned specialties</E> shall mean canned specialties resulting from a combination of fresh and pre-processed tomatoes, starches, cheeses, spices, and other flavorings necessary to produce a variety of products similar to but not exclusively raviolis, spaghetti, tamales, and enchiladas.</P>
          <P>(l) The term <E T="03">medium</E> shall mean a point source that processes a total annual raw material production of fruits, vegetables, specialties and other products that is between 1,816 kkg (2,000 tons) per year and 9,080 kkg (10,000 tons) per year.</P>
          <P>(m) The term <E T="03">large</E> shall mean a point source that processes a total annual raw material production of fruits, vegetables, specialties and other products that exceeds 9,080 kkg (10,000 tons) per year.</P>
          <P>(n) The term <E T="03">annual average</E> shall mean the maximum allowable discharge of BOD<E T="03">5</E> or TSS, as calculated by multiplying the total mass (kkg or 1000 lb) of each final product produced for the entire processing season or calendar year by the applicable annual average limitation.</P>
          <P>(o) The terms <E T="03">maximum for any one day</E> and <E T="03">average of daily values for thirty consecutive days</E> shall be based on the daily average mass of final product produced during the peak thirty consecutive day production period.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.82</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) The following limitations establish the quantity of BOD<E T="03">5</E> controlled by this section, which may be discharged by a “medium” or “large” existing point source subject to the provisions of this subpart after application of the best practicable control technology currently available. Any food specialty plant which continuously or intermittently discharges process waste water during the processing season shall meet the annual average, maximum thirty day average, and maximum day BOD<E T="03">5</E> limitations. Food specialty plants employing long term waste stabilization, where all or a portion of the process waste water discharge is stored for the entire processing season and release at a controlled rate with state approval, shall meet only the annual average BOD<E T="03">5</E> limitations. Effluent limitations for the soups subcategory are based upon pounds (lb) or kilograms (kg) of pollutant per 1000 pounds (lb) or kilograms (kkg) of raw ingredients.</P>
          <GPOTABLE CDEF="s25,7,12,7" COLS="4" OPTS="L2">
            <TDESC>[Metric units, kg/kkg of final product; English units, lb/1,000 lb of final product]</TDESC>
            <BOXHD>
              <CHED H="1">Commodity (specialties)</CHED>
              <CHED H="1">BOD<E T="03">5</E> effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
              <CHED H="2">Annual average shall not exceed—</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">Added ingredients</ENT>
              <ENT>0.95</ENT>
              <ENT>0.55</ENT>
              <ENT>0.36</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Baby food</ENT>
              <ENT>1.23</ENT>
              <ENT>0.73</ENT>
              <ENT>0.51</ENT>
            </ROW>
            <ROW>
              <ENT I="11">Chips:</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Corn</ENT>
              <ENT>1.58</ENT>
              <ENT>1.04</ENT>
              <ENT>0.80</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Potato</ENT>
              <ENT>3.46</ENT>
              <ENT>2.17</ENT>
              <ENT>1.58</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Tortilla</ENT>
              <ENT>2.41</ENT>
              <ENT>1.50</ENT>
              <ENT>1.09</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Ethnic foods</ENT>
              <ENT>2.39</ENT>
              <ENT>1.41</ENT>
              <ENT>0.96</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Jams/jellies</ENT>
              <ENT>0.42</ENT>
              <ENT>0.26</ENT>
              <ENT>0.19</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Mayonnaise and dressings</ENT>
              <ENT>0.37</ENT>
              <ENT>0.24</ENT>
              <ENT>0.17</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Soups</ENT>
              <ENT>4.14</ENT>
              <ENT>2.46</ENT>
              <ENT>1.69</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Tomato-starch-cheese canned specialties</ENT>
              <ENT>1.87</ENT>
              <ENT>1.08</ENT>
              <ENT>0.72</ENT>
            </ROW>
          </GPOTABLE>

          <P>(b) The following limitations establish the quantity of TSS controlled by this section, which may be discharged by a “medium” or “large” existing point source subject to the provisions of this subpart after application of the best practicable control technology currently available. Any food specialty plant which continuously or intermittently discharges process waste water during the processing season shall meet the annual average, maximum thirty day average, and maximum day TSS limitations. Food specialty plants employing long term waste stabilization, where all or a portion of the process waste water discharge is stored for the entire processing season and released at a controlled rate with state approval, shall meet only the annual average TSS limitations. Effluent limitations for the soups subcategory are based upon pounds (lb) or kilograms (kg) of pollutant per 1000 pounds (lb) or kilograms (kkg) of raw ingredients.<PRTPAGE P="105"/>
          </P>
          <GPOTABLE CDEF="s25,7,12,7" COLS="4" OPTS="L2">
            <TDESC>[Metric units, kg/kkg of final product; English units, lb/1,000 lb of final product]</TDESC>
            <BOXHD>
              <CHED H="1">Commodity (specialties)</CHED>
              <CHED H="1">TSS effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
              <CHED H="2">Annual average shall not exceed—</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">Added ingredients</ENT>
              <ENT>0.00</ENT>
              <ENT>0.00</ENT>
              <ENT>0.00</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Baby food</ENT>
              <ENT>2.23</ENT>
              <ENT>1.55</ENT>
              <ENT>0.95</ENT>
            </ROW>
            <ROW>
              <ENT I="11">Chips:</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Corn</ENT>
              <ENT>2.90</ENT>
              <ENT>2.17</ENT>
              <ENT>1.53</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Potato</ENT>
              <ENT>6.25</ENT>
              <ENT>4.49</ENT>
              <ENT>2.97</ENT>
            </ROW>
            <ROW>
              <ENT I="02">Tortilla</ENT>
              <ENT>4.34</ENT>
              <ENT>3.11</ENT>
              <ENT>2.04</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Ethnic foods</ENT>
              <ENT>4.23</ENT>
              <ENT>2.91</ENT>
              <ENT>1.73</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Jams/jellies</ENT>
              <ENT>0.76</ENT>
              <ENT>0.54</ENT>
              <ENT>0.36</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Mayonnaise and dressings</ENT>
              <ENT>0.67</ENT>
              <ENT>0.49</ENT>
              <ENT>0.33</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Soups</ENT>
              <ENT>7.38</ENT>
              <ENT>5.09</ENT>
              <ENT>3.10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Tomato-starch-cheese canned specialties</ENT>
              <ENT>3.31</ENT>
              <ENT>2.23</ENT>
              <ENT>1.30</ENT>
            </ROW>
          </GPOTABLE>
          <P>(c) The following limitations establish the quality of pH controlled by this section, which may be discharged by a “medium” or “large” existing point source subject to the provisions of this subpart after application of the best practicable control technology currently available.</P>
          <GPOTABLE CDEF="s40,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Shall not exceed 20 mg/l.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>At all times within the range 6.0 to 9.5 exceed 10 mg/l.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>At all times within the range 6.0 to 9.5.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[41 FR 16284, Apr. 16, 1976, as amended at 60 FR 33939, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.83</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.84</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by any existing point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[41 FR 16281, Apr. 16, 1976, as amended at 60 FR 33939, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.85</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.86</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[41 FR 16281, Apr. 16, 1976, as amended at 60 FR 33939, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 407.87</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 407.82 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
    </PART>
    <PART>
      <EAR>Pt. 408</EAR>
      <HD SOURCE="HED">PART 408—CANNED AND PRESERVED SEAFOOD PROCESSING POINT SOURCE CATEGORY</HD>
      <CONTENTS>
        <SUBPART>
          <HD SOURCE="HED">Subpart A—Farm-Raised Catfish Processing Subcategory</HD>
          <SECHD>Sec.</SECHD>
          <SECTNO>408.10</SECTNO>

          <SUBJECT>Applicability; description of the farm-raised catfish processing subcategory.<PRTPAGE P="106"/>
          </SUBJECT>
          <SECTNO>408.11</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.12</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.13</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.14</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.15</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.16</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.17</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart B—Conventional Blue Crab Processing Subcategory</HD>
          <SECTNO>408.20</SECTNO>
          <SUBJECT>Applicability; description of the conventional blue crab processing subcategory.</SUBJECT>
          <SECTNO>408.21</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.22</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.23</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.24</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.25</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.26</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.27</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart C—Mechanized Blue Crab Processing Subcategory</HD>
          <SECTNO>408.30</SECTNO>
          <SUBJECT>Applicability; description of the mechanized blue crab processing subcategory.</SUBJECT>
          <SECTNO>408.31</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.32</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.33</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.34</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.35</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.36</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.37</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart D—Non-Remote Alaskan Crab Meat Processing Subcategory</HD>
          <SECTNO>408.40</SECTNO>
          <SUBJECT>Applicability; description of the non-remote Alaskan crab meat processing subcategory.</SUBJECT>
          <SECTNO>408.41</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.42</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.43</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.44</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.45</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.46</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.47</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart E—Remote Alaskan Crab Meat Processing Subcategory</HD>
          <SECTNO>408.50</SECTNO>
          <SUBJECT>Applicability; description of the remote Alaskan crab meat processing subcategory.</SUBJECT>
          <SECTNO>408.51</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.52</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.53</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.54</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.55</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.56</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.57</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart F—Non-Remote Alaskan Whole Crab and Crab Section Processing Subcategory</HD>
          <SECTNO>408.60</SECTNO>
          <SUBJECT>Applicability; description of the non-remote Alaskan whole crab and crab section processing subcategory.</SUBJECT>
          <SECTNO>408.61</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.62</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.63</SECTNO>
          <SUBJECT>[Reserved]<PRTPAGE P="107"/>
          </SUBJECT>
          <SECTNO>408.64</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.65</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.66</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.67</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart G—Remote Alaskan Whole Crab and Crab Section Processing Subcategory</HD>
          <SECTNO>408.70</SECTNO>
          <SUBJECT>Applicability; description of the remote Alaskan whole crab and crab section processing subcategory.</SUBJECT>
          <SECTNO>408.71</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.72</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.73</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.74</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.75</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.76</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.77</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart H—Dungeness and Tanner Crab Pro-cessing in the Contiguous States Subcategory</HD>
          <SECTNO>408.80</SECTNO>
          <SUBJECT>Applicability; description of the dungeness and tanner crab processing in the contiguous States subcategory.</SUBJECT>
          <SECTNO>408.81</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.82</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.83</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.84</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.85</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.86</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.87</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart I—Non-Remote Alaskan Shrimp Processing Subcategory</HD>
          <SECTNO>408.90</SECTNO>
          <SUBJECT>Applicability; description of the non-remote Alaskan shrimp processing subcategory.</SUBJECT>
          <SECTNO>408.91</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.92</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.93</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.94</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.95</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.96</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.97</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart J—Remote Alaskan Shrimp Processing Subcategory</HD>
          <SECTNO>408.100</SECTNO>
          <SUBJECT>Applicability; description of the remote Alaskan shrimp processing subcategory.</SUBJECT>
          <SECTNO>408.101</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.102</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.103</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.104</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.105</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.106</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.107</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart K—Northern Shrimp Processing in the Contiguous States Subcategory</HD>
          <SECTNO>408.110</SECTNO>
          <SUBJECT>Applicability; description of the Northern shrimp processing in the contiguous States subcategory.</SUBJECT>
          <SECTNO>408.111</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.112</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.113</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.114</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.115</SECTNO>
          <SUBJECT>Standards of performance for new sources.<PRTPAGE P="108"/>
          </SUBJECT>
          <SECTNO>408.116</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.117</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart L—Southern Non-Breaded Shrimp Processing in the Contiguous States Subcategory</HD>
          <SECTNO>408.120</SECTNO>
          <SUBJECT>Applicability; description of the Southern non-breaded shrimp processing in the contiguous States subcategory.</SUBJECT>
          <SECTNO>408.121</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.122</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.123</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.124</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.125</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.126</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.127</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart M—Breaded Shrimp Processing in the Contiguous States Subcategory</HD>
          <SECTNO>408.130</SECTNO>
          <SUBJECT>Applicability; description of the breaded shrimp processing in the contiguous States subcategory.</SUBJECT>
          <SECTNO>408.131</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.132</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.133</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.134</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.135</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.136</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.137</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart N—Tuna Processing Subcategory</HD>
          <SECTNO>408.140</SECTNO>
          <SUBJECT>Applicability; description of the tuna processing subcategory.</SUBJECT>
          <SECTNO>408.141</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.142</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.143</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.144</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.145</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.146</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.147</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart O—Fish Meal Processing Subcategory</HD>
          <SECTNO>408.150</SECTNO>
          <SUBJECT>Applicability; description of the fish meal processing subcategory.</SUBJECT>
          <SECTNO>408.151</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.152</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.153</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.154</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.155</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.156</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.157</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart P—Alaskan Hand-Butchered Salmon Processing Subcategory</HD>
          <SECTNO>408.160</SECTNO>
          <SUBJECT>Applicability; description of the Alaskan hand-butchered salmon processing subcategory.</SUBJECT>
          <SECTNO>408.161</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.162</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.163</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.164</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.165</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.166</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.167</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.</SUBJECT>
        </SUBPART>
        <SUBPART>
          <PRTPAGE P="109"/>
          <HD SOURCE="HED">Subpart Q—Alaskan Mechanized Salmon Processing Subcategory</HD>
          <SECTNO>408.170</SECTNO>
          <SUBJECT>Applicability; description of the Alaskan mechanized salmon processing subcategory.</SUBJECT>
          <SECTNO>408.171</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.172</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.173</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.174</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.175</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.176</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.177</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart R—West Coast Hand-Butchered Salmon Processing Subcategory</HD>
          <SECTNO>408.180</SECTNO>
          <SUBJECT>Applicability; description of the West Coast hand-butchered salmon processing subcategory.</SUBJECT>
          <SECTNO>408.181</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.182</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.183</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.184</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.185</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.186</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.187</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart S—West Coast Mechanized Salmon Processing Subcategory</HD>
          <SECTNO>408.190</SECTNO>
          <SUBJECT>Applicability; description of the West Coast mechanized salmon processing subcategory.</SUBJECT>
          <SECTNO>408.191</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.192</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reductionattainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.193</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.194</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.195</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.196</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.197</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart T—Alaskan Bottom Fish Processing Subcategory</HD>
          <SECTNO>408.200</SECTNO>
          <SUBJECT>Applicability; description of the Alaskan bottom fish processing subcategory.</SUBJECT>
          <SECTNO>408.201</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.202</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.203</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.204</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.205</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.206</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.207</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart U—Non-Alaskan Conventional Bottom Fish Processing Subcategory</HD>
          <SECTNO>408.210</SECTNO>
          <SUBJECT>Applicability; description of the non-Alaskan conventional bottom fish processing subcategory.</SUBJECT>
          <SECTNO>408.211</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.212</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.213</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.214</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.215</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.216</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.217</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart V—Non-Alaskan Mechanized Bottom Fish Processing Subcategory</HD>
          <SECTNO>408.220</SECTNO>
          <SUBJECT>Applicability; description of the non-Alaskan mechanized bottom fish processing subcategory.</SUBJECT>
          <SECTNO>408.221</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.222</SECTNO>

          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction <PRTPAGE P="110"/>attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.223</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.224</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.225</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.226</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.227</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart W—Hand-Shucked Clam Processing Subcategory</HD>
          <SECTNO>408.230</SECTNO>
          <SUBJECT>Applicability; description of the hand-shucked clam processing subcategory.</SUBJECT>
          <SECTNO>408.231</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.232</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.233</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.234</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.235</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.236</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.237</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart X—Mechanized Clam Processing Subcategory</HD>
          <SECTNO>408.240</SECTNO>
          <SUBJECT>Applicability; description of the mechanized clam processing subcategory.</SUBJECT>
          <SECTNO>408.241</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.242</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.243</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.244</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.245</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.246</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.247</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart Y—Pacific Coast Hand-Shucked Oyster Processing Subcategory</HD>
          <SECTNO>408.250</SECTNO>
          <SUBJECT>Applicability; description of the Pacific Coast hand-shucked oyster processing subcategory.</SUBJECT>
          <SECTNO>408.251</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.252</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.253</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.254</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.255</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.256</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.257</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart Z—Atlantic and Gulf Coast Hand-Shucked Oyster Processing Subcategory</HD>
          <SECTNO>408.260</SECTNO>
          <SUBJECT>Applicability; description of the Atlantic and Gulf Coast hand-shucked oyster processing subcategory.</SUBJECT>
          <SECTNO>408.261</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.262</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.263</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.264</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.265</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.266</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.267</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart AA—Steamed and Canned Oyster Processing Subcategory</HD>
          <SECTNO>408.270</SECTNO>
          <SUBJECT>Applicability; description of the steamed and canned oyster processing subcategory.</SUBJECT>
          <SECTNO>408.271</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.272</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.273</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.274</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.275</SECTNO>
          <SUBJECT>Standards of performance for new sources.<PRTPAGE P="111"/>
          </SUBJECT>
          <SECTNO>408.276</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.277</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart AB—Sardine Processing Subcategory</HD>
          <SECTNO>408.280</SECTNO>
          <SUBJECT>Applicability; description of the sardine processing subcategory.</SUBJECT>
          <SECTNO>408.281</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.282</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.283</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.284</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.285</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.286</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.287</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart AC—Alaskan Scallop Processing Subcategory</HD>
          <SECTNO>408.290</SECTNO>
          <SUBJECT>Applicability; description of the Alaskan scallop processing subcategory.</SUBJECT>
          <SECTNO>408.291</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.292</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.293</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.294</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.295</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.296</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.297</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart AD—Non-Alaskan Scallop Processing Subcategory</HD>
          <SECTNO>408.300</SECTNO>
          <SUBJECT>Applicability; description of the non-Alaskan scallop processing subcategory.</SUBJECT>
          <SECTNO>408.301</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.302</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.303</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.304</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.305</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.306</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.307</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart AE—Alaskan Herring Fillet Processing Subcategory</HD>
          <SECTNO>408.310</SECTNO>
          <SUBJECT>Applicability; description of the Alaskan herring fillet processing subcategory.</SUBJECT>
          <SECTNO>408.311</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.312</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.313</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.314</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.315</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.316</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.317</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart AF—Non-Alaskan Herring Fillet Processing Subcategory</HD>
          <SECTNO>408.320</SECTNO>
          <SUBJECT>Applicability; description of the non-Alaskan herring fillet processing subcategory.</SUBJECT>
          <SECTNO>408.321</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.322</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.323</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.324</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.325</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.326</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.327</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <PRTPAGE P="112"/>
          <HD SOURCE="HED">Subpart AG—Abalone Processing Subcategory</HD>
          <SECTNO>408.330</SECTNO>
          <SUBJECT>Applicability; description of the abalone processing subcategory.</SUBJECT>
          <SECTNO>408.331</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>408.332</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>408.333</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>408.334</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>408.335</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>408.336</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>408.337</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.</SUBJECT>
        </SUBPART>
      </CONTENTS>
      <AUTH>
        <HD SOURCE="HED">Authority:</HD>
        <P>Secs. 301, 304 (b) and (c), 306 (b) and (c), 307(c), of the Federal Water Pollution Control Act, as amended; 33 U.S.C. 1251, 1311, 1314 (b) and (c), 1316 (b) and (c), 1317(c); 86 Stat. 816 et seq., Pub. L. 92-500; 91 Stat. 1567, Pub. L. 95-217.</P>
      </AUTH>
      <SOURCE>
        <HD SOURCE="HED">Source:</HD>
        <P>39 FR 23140, June 26, 1974, unless otherwise noted.</P>
      </SOURCE>
      <SUBPART>
        <HD SOURCE="HED">Subpart A—Farm-Raised Catfish Processing Subcategory</HD>
        <SECTION>
          <SECTNO>§ 408.10</SECTNO>
          <SUBJECT>Applicability; description of the farm-raised catfish processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of farm-raised catfish by existing facilities which process more than 1362 kg (3000 lbs) of raw material per day on any day during a calendar year and all new sources.</P>
          <CITA>[40 FR 55780, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.11</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">oil and grease</E> shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217.</P>
          <P>(c) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.12</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>28</ENT>
              <ENT>9.2</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>10</ENT>
              <ENT>3.4</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>28</ENT>
              <ENT>9.2</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>10</ENT>
              <ENT>3.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 23140, June 26, 1974, as amended at 60 FR 33940, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.13</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.14</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <PRTPAGE P="113"/>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6437, Feb. 11, 1975, as amended at 60 FR 33940, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.15</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>4.6</ENT>
              <ENT>2.3</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>11</ENT>
              <ENT>5.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.90</ENT>
              <ENT>0.45</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>4.6</ENT>
              <ENT>2.3</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>11</ENT>
              <ENT>5.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.90</ENT>
              <ENT>0.45</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.16</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33940, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.17</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.12 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart B—Conventional Blue Crab Processing Subcategory</HD>
        <SECTION>
          <SECTNO>§ 408.20</SECTNO>
          <SUBJECT>Applicability; description of the conventional blue crab processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of blue crab in which manual picking or separation of crab meat from the shell is utilized. The effluent limitations contained in this subpart B are applicable to existing facilities processing more than 1362 kg (3000 lbs) of raw material per day on any day during a calendar year and all new sources.</P>
          <CITA>[40 FR 55780, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.21</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">oil and grease</E> shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217.</P>
          <P>(c) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.22</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall <PRTPAGE P="114"/>achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.2</ENT>
              <ENT>0.74</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.60</ENT>
              <ENT>0.20</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.2</ENT>
              <ENT>0.74</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.60</ENT>
              <ENT>0.20</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 23140, June 26, 1974, as amended at 60 FR 33940, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.23</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.24</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6438, Feb. 11, 1975, as amended at 60 FR 33940, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.25</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.30</ENT>
              <ENT>0.15</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.90</ENT>
              <ENT>0.45</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.13</ENT>
              <ENT>0.065</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.30</ENT>
              <ENT>0.15</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.90</ENT>
              <ENT>0.45</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.13</ENT>
              <ENT>0.065</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.26</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33940, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.27</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.22 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart C—Mechanized Blue Crab Processing Subcategory</HD>
        <SECTION>
          <SECTNO>§ 408.30</SECTNO>
          <SUBJECT>Applicability; description of the mechanized blue crab processing subcategory.</SUBJECT>

          <P>The provisions of this subpart are applicable to discharges resulting from <PRTPAGE P="115"/>the processing of blue crab in which mechanical picking or separation of crab meat from the shell is utilized.</P>
          <CITA>[40 FR 55780, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.31</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">oil and grease</E> shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217.</P>
          <P>(c) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.32</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>36</ENT>
              <ENT>12.0</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>13</ENT>
              <ENT>4.2</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>36</ENT>
              <ENT>12.0</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>13</ENT>
              <ENT>4.2</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 23140, June 26, 1974, as amended at 60 FR 33941, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.33</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.34</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6438, Feb. 11, 1975, as amended at 60 FR 33941, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.35</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>5.0</ENT>
              <ENT>2.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>13</ENT>
              <ENT>6.3</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.6</ENT>
              <ENT>1.3</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>5.0</ENT>
              <ENT>2.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>13</ENT>
              <ENT>6.3</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.6</ENT>
              <ENT>1.3</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.36</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>

          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned <PRTPAGE P="116"/>treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33941, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.37</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.32 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart D—Non-Remote Alaskan Crab Meat Processing Subcategory</HD>
        <SECTION>
          <SECTNO>§ 408.40</SECTNO>
          <SUBJECT>Applicability; description of the non-remote Alaskan crab meat processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing, in non-remote Alaska, of dungeness, tanner, and king crab meat. The effluent limitations contained in this subpart D are applicable to facilities located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg.</P>
          <CITA>[40 FR 55780, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.41</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">oil and grease</E> shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217.</P>
          <P>(c) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.42</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>19</ENT>
              <ENT>6.2</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.8</ENT>
              <ENT>0.61</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>19</ENT>
              <ENT>6.2</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.8</ENT>
              <ENT>0.61</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 23140, June 26, 1974, as amended at 60 FR 33941, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.43</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.44</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>

          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.<PRTPAGE P="117"/>
          </P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6438, Feb. 11, 1975, as amended at 60 FR 33941, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.45</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>16</ENT>
              <ENT>5.3</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.6</ENT>
              <ENT>0.52</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>16</ENT>
              <ENT>5.3</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.6</ENT>
              <ENT>0.52</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.46</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33941, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.47</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.42 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart E—Remote Alaskan Crab Meat Processing Subcategory</HD>
        <SECTION>
          <SECTNO>§ 408.50</SECTNO>
          <SUBJECT>Applicability; description of the remote Alaskan crab meat processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing, in remote Alaska, of dungeness, tanner, and king crab meat. The effluent limitations contained in subpart E are applicable to facilities not covered under subpart D.</P>
          <CITA>[40 FR 55780, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.51</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">oil and grease</E> shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217.</P>
          <P>(c) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.52</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.</P>
          <CITA>[60 FR 33941, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <PRTPAGE P="118"/>
          <SECTNO>§ 408.53</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.54</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6438, Feb. 11, 1975, as amended at 60 FR 33941, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.55</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.</P>
          <CITA>[40 FR 55780, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.56</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33941, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.57</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.52 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart F—Non-Remote Alaskan Whole Crab and Crab Section Processing Subcategory</HD>
        <SECTION>
          <SECTNO>§ 408.60</SECTNO>
          <SUBJECT>Applicability; description of the non-remote Alaskan whole crab and crab section processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing, in non-remote Alaska, of dungeness, tanner and king whole crab and crab sections. The effluent limitations contained in this subpart F are applicable to facilities located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg.</P>
          <CITA>[40 FR 55780, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.61</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">oil and grease</E> shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217.</P>
          <P>(c) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.62</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall <PRTPAGE P="119"/>achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>12</ENT>
              <ENT>12</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.3</ENT>
              <ENT>0.42</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>12</ENT>
              <ENT>3.9</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.3</ENT>
              <ENT>0.42</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 23140, June 26, 1974, as amended at 60 FR 33941, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.63</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.64</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6438, Feb. 11, 1975, as amended at 60 FR 33941, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.65</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood—</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>9.9</ENT>
              <ENT>3.3</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.1</ENT>
              <ENT>0.36</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>9.9</ENT>
              <ENT>3.3</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.1</ENT>
              <ENT>0.36</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.66</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33941, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.67</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.62 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart G—Remote Alaskan Whole Crab and Crab Section Processing Subcategory</HD>
        <SECTION>
          <SECTNO>§ 408.70</SECTNO>
          <SUBJECT>Applicability; description of the remote Alaskan whole crab and crab section processing subcategory.</SUBJECT>

          <P>The provisions of this subpart are applicable to discharges resulting from <PRTPAGE P="120"/>the processing, in remote Alaska, of dungeness, tanner, and king whole crab and crab sections. The effluent limitations contained in this subpart G are applicable to facilities not covered under subpart F of this part.</P>
          <CITA>[40 FR 55780, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.71</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">oil and grease</E> shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217.</P>
          <P>(c) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.72</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.</P>
          <CITA>[60 FR 33941, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.73</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.74</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6438, Feb. 11, 1975, as amended at 60 FR 33942, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.75</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.</P>
          <CITA>[40 FR 55780, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.76</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33942, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.77</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.72 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <PRTPAGE P="121"/>
        <HD SOURCE="HED">Subpart H—Dungeness and Tanner Crab Processing in the Contiguous States Subcategory</HD>
        <SECTION>
          <SECTNO>§ 408.80</SECTNO>
          <SUBJECT>Applicability; description of the dungeness and tanner crab processing in the contiguous States subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of dungeness and tanner crab in the contiguous States.</P>
          <CITA>[40 FR 55780, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.81</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">oil and grease</E> shall mean those components of a waste water amendable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217.</P>
          <P>(c) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.82</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>8.1</ENT>
              <ENT>2.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.8</ENT>
              <ENT>0.61</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>8.1</ENT>
              <ENT>2.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.8</ENT>
              <ENT>0.61</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 23140, June 26, 1974, as amended at 60 FR 33942, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.83</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.84</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6438, Feb. 11, 1975, as amended at 60 FR 33942, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.85</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>10</ENT>
              <ENT>4.1</ENT>
            </ROW>
            <ROW>
              <PRTPAGE P="122"/>
              <ENT I="01">TSS</ENT>
              <ENT>1.7</ENT>
              <ENT>0.69</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.25</ENT>
              <ENT>0.10</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>10</ENT>
              <ENT>4.1</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.7</ENT>
              <ENT>0.69</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.25</ENT>
              <ENT>0.10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.86</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33942, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.87</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.82 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart I—Non-Remote Alaskan Shrimp Processing Subcategory</HD>
        <SECTION>
          <SECTNO>§ 408.90</SECTNO>
          <SUBJECT>Applicability; description of the non-remote Alaskan shrimp processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of shrimp in non-remote Alaska. The effluent limitations contained in this subpart I are applicable to facilities located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg.</P>
          <CITA>[40 FR 55780, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.91</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">oil and grease</E> shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217.</P>
          <P>(c) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.92</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>320</ENT>
              <ENT>210</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>51</ENT>
              <ENT>17</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>320</ENT>
              <ENT>210</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>51</ENT>
              <ENT>17</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <PRTPAGE P="123"/>
          <CITA>[39 FR 23140, June 26, 1974, as amended at 60 FR 33942, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.93</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.94</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6438, Feb. 11, 1975, as amended at 60 FR 33942, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.95</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>270</ENT>
              <ENT>180</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>45</ENT>
              <ENT>15</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>270</ENT>
              <ENT>180</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>45</ENT>
              <ENT>15</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.96</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33942, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.97</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.92 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart J—Remote Alaskan Shrimp Processing Subcategory</HD>
        <SECTION>
          <SECTNO>§ 408.100</SECTNO>
          <SUBJECT>Applicability; description of the remote Alaskan shrimp processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of shrimp in remote Alaska. The effluent limitations contained in this subpart J are applicable to facilities not covered under subpart I of this part.</P>
          <CITA>[40 FR 55781, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.101</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">oil and grease</E> shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217.</P>
          <P>(c) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and <PRTPAGE P="124"/>saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.102</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.</P>
          <CITA>[60 FR 33942, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.103</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.104</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6439, Feb. 11, 1975, as amended at 60 FR 33942, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.105</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.</P>
          <CITA>[40 FR 55781, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.106</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33942, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.107</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.102 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart K—Northern Shrimp Processing in the Contiguous States Sub-cat-egory</HD>
        <SECTION>
          <SECTNO>§ 408.110</SECTNO>
          <SUBJECT>Applicability; description of the Northern shrimp processing in the contiguous States subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of shrimp in the Northern contiguous States, including Washington, Oregon, California, Maine, New Hampshire, and Massachusetts. The effluent limitations contained in this subpart K are applicable to existing facilities processing more than 908 kg (2000 lbs) of raw material per day on any day during a calendar year and all new sources.</P>
          <CITA>[40 FR 55781, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.111</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:<PRTPAGE P="125"/>
          </P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">oil and grease</E> shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217.</P>
          <P>(c) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.112</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>160</ENT>
              <ENT>54</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>126</ENT>
              <ENT>42</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>160</ENT>
              <ENT>54</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>126</ENT>
              <ENT>42</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 23140, June 26, 1974, as amended at 60 FR 33942, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.113</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.114</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6439, Feb. 11, 1975, as amended at 60 FR 33942, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.115</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>155</ENT>
              <ENT>62</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>38</ENT>
              <ENT>15</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>14</ENT>
              <ENT>5.7</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>155</ENT>
              <ENT>62</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>38</ENT>
              <ENT>15</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>14</ENT>
              <ENT>5.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.116</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33943, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <PRTPAGE P="126"/>
          <SECTNO>§ 408.117</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.112 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart L—Southern Non-Breaded Shrimp Processing in the Contiguous States Subcategory</HD>
        <SECTION>
          <SECTNO>§ 408.120</SECTNO>
          <SUBJECT>Applicability; description of the Southern non-breaded shrimp processing in the contiguous States subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of non-breaded shrimp in the Southern contiguous States, including North and South Carolina, Georgia, Florida, Alabama, Mississippi, Louisiana, and Texas. The effluent limitations contained in this subpart L are applicable to existing facilities processing more than 908 kg (2000 lbs) of raw material per day on any day during a calendar year and all new sources.</P>
          <CITA>[40 FR 55781, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.121</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">oil and grease</E> shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217.</P>
          <P>(c) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.122</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>110</ENT>
              <ENT>38</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>36</ENT>
              <ENT>12</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>110</ENT>
              <ENT>38</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>36</ENT>
              <ENT>12</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 23140, June 26, 1974, as amended at 60 FR 33943, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.123</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.124</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>

          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.<PRTPAGE P="127"/>
          </P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6439, Feb. 11, 1975, as amended at 60 FR 33943, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.125</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>63</ENT>
              <ENT>25</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>25</ENT>
              <ENT>10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>4.0</ENT>
              <ENT>1.6</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>63</ENT>
              <ENT>25</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>25</ENT>
              <ENT>10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>4.0</ENT>
              <ENT>1.6</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.126</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33943, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.127</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.122 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart M—Breaded Shrimp Processing in the Contiguous States Sub-cat-egory</HD>
        <SECTION>
          <SECTNO>§ 408.130</SECTNO>
          <SUBJECT>Applicability; description of the breaded shrimp processing in the contiguous States subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of breaded shrimp in the contiguous States by existing facilities processing more than 908 kg (2000 lbs) of raw material per day on any day during a calendar year and all new sources.</P>
          <CITA>[40 FR 55781, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.131</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">oil and grease</E> shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217.</P>
          <P>(c) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.132</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall <PRTPAGE P="128"/>achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>280</ENT>
              <ENT>93</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>36</ENT>
              <ENT>12</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>280</ENT>
              <ENT>93</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>36</ENT>
              <ENT>12</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 23140, June 26, 1974, as amended at 60 FR 33943, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.133</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.134</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6439, Feb. 11, 1975, as amended at 60 FR 33943, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.135</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>100</ENT>
              <ENT>40</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>55</ENT>
              <ENT>22</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>3.8</ENT>
              <ENT>1.5</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>100</ENT>
              <ENT>40</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>55</ENT>
              <ENT>22</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>3.8</ENT>
              <ENT>1.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.136</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33943, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.137</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.132 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <PRTPAGE P="129"/>
        <HD SOURCE="HED">Subpart N—Tuna Processing Subcategory</HD>
        <SECTION>
          <SECTNO>§ 408.140</SECTNO>
          <SUBJECT>Applicability; description of the tuna processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of tuna.</P>
          <CITA>[40 FR 55781, Dec. 1, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.141</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">oil and grease</E> shall mean those components of a waste water amenable to measurement by the method described in Methods for Chemical Analysis of Water and Wastes, 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 217.</P>
          <P>(c) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.142</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>8.3</ENT>
              <ENT>3.3</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.1</ENT>
              <ENT>0.84</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>8.3</ENT>
              <ENT>3.3</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.1</ENT>
              <ENT>0.84</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[39 FR 23140, June 26, 1974, as amended at 44 FR 45945, Aug. 9, 1979; 60 FR 33943, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.143</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.144</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6439, Feb. 11, 1975, as amended at 60 FR 33943, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.145</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>20</ENT>
              <ENT>8.1</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>7.5</ENT>
              <ENT>3.0</ENT>
            </ROW>
            <ROW>
              <PRTPAGE P="130"/>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.9</ENT>
              <ENT>0.76</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>20</ENT>
              <ENT>8.1</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>7.5</ENT>
              <ENT>3.0</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.9</ENT>
              <ENT>0.76</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.146</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33943, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.147</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.142 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart O—Fish Meal Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55781, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.150</SECTNO>
          <SUBJECT>Applicability; description of the fish meal processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of menhaden on the Gulf and Atlantic Coasts and the processing of anchovy on the West Coast into fish meal, oil and solubles.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.151</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.152</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <P>(a) Any menhaden or anchovy fish meal reduction facility which utilizes a solubles plant to process stick water or bail water shall meet the following limitations.</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>7.0</ENT>
              <ENT>3.9</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>3.7</ENT>
              <ENT>1.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.4</ENT>
              <ENT>0.76</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>7.0</ENT>
              <ENT>3.9</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>3.7</ENT>
              <ENT>1.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.4</ENT>
              <ENT>0.76</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(b) Any menhaden or anchovy fish meal reduction facility not covered <PRTPAGE P="131"/>under § 408.152(a) shall meet the following limitations:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>3.5</ENT>
              <ENT>2.8</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.6</ENT>
              <ENT>1.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>3.2</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>3.5</ENT>
              <ENT>2.8</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.6</ENT>
              <ENT>1.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>3.2</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55781, Dec. 1, 1975, as amended at 41 FR 31821, July 30, 1976; 60 FR 33943, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.153</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.154</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55781, Dec. 1, 1975, as amended at 60 FR 33943, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.155</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>6.7</ENT>
              <ENT>3.8</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>3.7</ENT>
              <ENT>1.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.4</ENT>
              <ENT>0.76</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>6.7</ENT>
              <ENT>3.8</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>3.7</ENT>
              <ENT>1.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.4</ENT>
              <ENT>0.76</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55781, Dec. 1, 1975, as amended at 41 FR 31821, July 30, 1976]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.156</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55781, Dec. 1, 1975, as amended at 60 FR 33944, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.157</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall <PRTPAGE P="132"/>achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.152 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart P—Alaskan Hand-Butchered Salmon Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55782, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.160</SECTNO>
          <SUBJECT>Applicability; description of the Alaskan hand-butchered salmon processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the hand-butchering of salmon in Alaska.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.161</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.162</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <P>(a) Any hand-butchered salmon processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.6</ENT>
              <ENT>1.6</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.31</ENT>
              <ENT>0.19</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.6</ENT>
              <ENT>1.6</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.31</ENT>
              <ENT>0.19</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <P>(b) Any hand-butchered salmon processing facility not covered under § 408.162(a) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.</P>
          <CITA>[40 FR 55782, Dec. 1, 1975, as amended at 41 FR 31821, July 30, 1976; 60 FR 33944, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.163</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.164</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">Pretreatment standard</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55781, Dec. 1, 1975, as amended at 60 FR 33944, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <PRTPAGE P="133"/>
          <SECTNO>§ 408.165</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>(a) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <P>(1) Any hand-butchered salmon processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.3</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.28</ENT>
              <ENT>0.17</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.3</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.28</ENT>
              <ENT>0.17</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <P>(2) Any hand-butchered salmon processing facility not covered under § 408.165(a)(1) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.</P>
          <P>(b) [Reserved]</P>
          <CITA>[40 FR 55782, Dec. 1, 1975, as amended at 41 FR 31821, July 30, 1976]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.166</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">Pretreatment standard</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55781, Dec. 1, 1975, as amended at 60 FR 33944, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.167</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.</SUBJECT>
          <P>(a) [Reserved]</P>
          <P>(b) Except as provided in §§ 125.30 through 125.32, any hand-butchered salmon processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.162(b)(2) of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24998, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart Q—Alaskan Mechanized Salmon Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55783, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.170</SECTNO>
          <SUBJECT>Applicability; description of the Alaskan mechanized salmon processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the mechanized butchering of salmon in Alaska.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.171</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and <PRTPAGE P="134"/>saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.172</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <P>(a) Any mechanized salmon processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>44</ENT>
              <ENT>26</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>29</ENT>
              <ENT>11</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>44</ENT>
              <ENT>26</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>29</ENT>
              <ENT>11</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <P>(b) Any mechanized salmon processing facility not covered under § 408.172(a) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.</P>
          <CITA>[40 FR 55783, Dec. 1, 1975, as amended at 41 FR 31821, July 30, 1976; 60 FR 33944, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.173</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.174</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55783, Dec. 1, 1975, as amended at 60 FR 33944, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.175</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>(a) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <P>(1) Any mechanized salmon processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>42</ENT>
              <ENT>25</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>28</ENT>
              <ENT>10</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>42</ENT>
              <ENT>25</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>28</ENT>
              <ENT>10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(2) Any mechanized salmon processing facility not covered under § 408.175(a)(1) shall meet the following <PRTPAGE P="135"/>limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.</P>
          <P>(b) [Reserved]</P>
          <CITA>[40 FR 55783, Dec. 1, 1975, as amended at 41 FR 31822, July 30, 1976]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.176</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">Pretreatment standard</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55783, Dec. 1, 1975, as amended at 60 FR 33944, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.177</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.172 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart R—West Coast Hand-Butchered Salmon Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55784, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.180</SECTNO>
          <SUBJECT>Applicability; description of the West Coast hand-butchered salmon processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the hand-butchering of salmon on the West Coast.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.181</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.182</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.6</ENT>
              <ENT>1.6</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.31</ENT>
              <ENT>0.19</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>2.6</ENT>
              <ENT>1.6</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.31</ENT>
              <ENT>0.19</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55784, Dec. 1, 1975, as amended at 41 FR 31822, July 30, 1976; 60 FR 33944, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <PRTPAGE P="136"/>
          <SECTNO>§ 408.183</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.184</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55784, Dec. 1, 1975, as amended at 60 FR 33944, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.185</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>2.7</ENT>
              <ENT>1.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.70</ENT>
              <ENT>0.42</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.045</ENT>
              <ENT>0.026</ENT>
            </ROW>
            <ROW RUL="n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>2.7</ENT>
              <ENT>1.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.70</ENT>
              <ENT>0.42</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.045</ENT>
              <ENT>0.026</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55784, Dec. 1, 1975, as amended at 41 FR 31822, July 30, 1976]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.186</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55783, Dec. 1, 1975, as amended at 60 FR 33945, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.187</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.182 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart S—West Coast Mechanized Salmon Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55786, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.190</SECTNO>
          <SUBJECT>Applicability; description of the West Coast mechanized salmon processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the mechanized butchering of salmon on the West Coast.</P>
        </SECTION>
        <SECTION>
          <PRTPAGE P="137"/>
          <SECTNO>§ 408.191</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.192</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>44</ENT>
              <ENT>26</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>29</ENT>
              <ENT>11</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>44</ENT>
              <ENT>26</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>29</ENT>
              <ENT>11</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55786, Dec. 1, 1975, as amended at 41 FR 31822, July 30, 1976; 60 FR 33945, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.193</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.194</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55786, Dec. 1, 1975, as amended at 60 FR 33945, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.195</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>62</ENT>
              <ENT>38</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>13</ENT>
              <ENT>7.6</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>4.2</ENT>
              <ENT>1.5</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>62</ENT>
              <ENT>38</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>13</ENT>
              <ENT>7.6</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>4.2</ENT>
              <ENT>1.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55786, Dec. 1, 1975, as amended at 41 FR 31822, July 30, 1976]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.196</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>

          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a <PRTPAGE P="138"/>new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55786, Dec. 1, 1975, as amended at 60 FR 33945, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.197</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.192 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart T—Alaskan Bottom Fish Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55787, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.200</SECTNO>
          <SUBJECT>Applicability; description of the Alaskan bottom fish processing sub-category.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of bottom fish such as halibut in Alaska.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.201</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.202</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <P>(a) Any Alaskan bottom fish processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>3.1</ENT>
              <ENT>1.9</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>4.3</ENT>
              <ENT>0.56</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>3.1</ENT>
              <ENT>1.9</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>4.3</ENT>
              <ENT>0.56</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <P>(b) Any Alaskan bottom-fish processing facility not covered under § 408.202(a) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.</P>
          <CITA>[40 FR 55787, Dec. 1, 1975, as amended at 60 FR 33945, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.203</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.204</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>

          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or <PRTPAGE P="139"/>pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55787, Dec. 1, 1975, as amended at 60 FR 33945, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.205</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>(a) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <P>(1) Any Alaskan bottom fish processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.9</ENT>
              <ENT>1.1</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.6</ENT>
              <ENT>0.34</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.9</ENT>
              <ENT>1.1</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.6</ENT>
              <ENT>0.34</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <P>(2) Any Alaskan bottom-fish processing facility not covered under § 408.205(a)(1) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.</P>
          <P>(b) [Reserved]</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.206</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55787, Dec. 1, 1975, as amended at 60 FR 33945, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.207</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.</SUBJECT>
          <P>(a) [Reserved]</P>
          <P>(b) Except as provided in §§ 125.30 through 125.32, any Alaskan bottom fish processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.202(b)(2) of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24998, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart U—Non-Alaskan Conventional Bottom Fish Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55788, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <PRTPAGE P="140"/>
          <SECTNO>§ 408.210</SECTNO>
          <SUBJECT>Applicability; description of the non-Alaskan conventional bottom fish processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of bottom fish outside of Alaska in which the unit operations are carried out predominately through manual methods. However, the use of scaling machines and/or skinning machines are considered to be normal practice within this subcategory. The provisions of this subpart apply to the processing of currently, commercially processed species of bottom fish such as flounder, ocean perch, haddock, cod, sea catfish, sole, halibut, and rockfish. These provisions apply to existing facilities processing more than 1816 kg (4000 lbs) of raw material per day on any day during a calendar year and all new sources.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.211</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.212</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>3.6</ENT>
              <ENT>2.0</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.0</ENT>
              <ENT>0.55</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>3.6</ENT>
              <ENT>2.0</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.0</ENT>
              <ENT>0.55</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55788, Dec. 1, 1975, as amended at 41 FR 31822, July 30, 1976; 60 FR 33945, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.213</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.214</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55788, Dec. 1, 1975, as amended at 60 FR 33945, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.215</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>

          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, <PRTPAGE P="141"/>controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.2</ENT>
              <ENT>0.71</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.5</ENT>
              <ENT>0.73</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.077</ENT>
              <ENT>0.042</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.2</ENT>
              <ENT>0.71</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.5</ENT>
              <ENT>0.73</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.077</ENT>
              <ENT>0.042</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55788, Dec. 1, 1975, as amended at 41 FR 31823, July 30, 1976]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.216</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55788, Dec. 1, 1975, as amended at 60 FR 33945, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.217</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.212 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart V—Non-Alaskan Mechanized Bottom Fish Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55789, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.220</SECTNO>
          <SUBJECT>Applicability; description of the non-Alaskan mechanized bottom fish processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of bottom fish outside of Alaska in which the unit operations (particularly the butchering and/or filleting operations) are carried out predominately through mechanized methods. The provisions of this subpart apply to the processing of bottom fish such as whiting and croaker.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.221</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.222</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):<PRTPAGE P="142"/>
          </P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>22</ENT>
              <ENT>12</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>9.9</ENT>
              <ENT>3.9</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>22</ENT>
              <ENT>12</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>9.9</ENT>
              <ENT>3.9</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55789, Dec. 1, 1975, as amended at 41 FR 31823, July 30, 1976; 60 FR 33946, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.223</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.224</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55789, Dec. 1, 1975, as amended at 60 FR 33946, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.225</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of perform-ance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>13</ENT>
              <ENT>7.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>5.3</ENT>
              <ENT>2.9</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.2</ENT>
              <ENT>0.47</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>13</ENT>
              <ENT>7.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>5.3</ENT>
              <ENT>2.9</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.2</ENT>
              <ENT>0.47</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55789, Dec. 1, 1975, as amended at 41 FR 31823, July 30, 1976]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.226</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55789, Dec. 1, 1975, as amended at 60 FR 33946, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.227</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall <PRTPAGE P="143"/>achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.222 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart W—Hand-Shucked Clam Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55790, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.230</SECTNO>
          <SUBJECT>Applicability; description of the hand-shucked clam processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from existing hand-shucked clam processing facilities which process more than 1816 kg (4000 lbs) of raw material per day on any day during a calendar year and all new sources.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.231</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.232</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>59</ENT>
              <ENT>18</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.60</ENT>
              <ENT>0.23</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>59</ENT>
              <ENT>18</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.60</ENT>
              <ENT>0.23</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55790, Dec. 1, 1975, as amended at 60 FR 33946, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.233</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.234</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55790, Dec. 1, 1975, as amended at 60 FR 33946, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.235</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>

          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:<PRTPAGE P="144"/>
          </P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>55</ENT>
              <ENT>17</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.56</ENT>
              <ENT>0.21</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>55</ENT>
              <ENT>17</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.56</ENT>
              <ENT>0.21</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.236</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55790, Dec. 1, 1975, as amended at 60 FR 33946, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.237</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.232 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart X—Mechanized Clam Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55791, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.240</SECTNO>
          <SUBJECT>Applicability; description of the mechanized clam processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from mechanized clam processing.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.241</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.242</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>90</ENT>
              <ENT>15</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>4.2</ENT>
              <ENT>0.97</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <PRTPAGE P="145"/>
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>90</ENT>
              <ENT>15</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>4.2</ENT>
              <ENT>0.97</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55791, Dec. 1, 1975, as amended at 60 FR 33946, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.243</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.244</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55791, Dec. 1, 1975, as amended at 60 FR 33946, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.245</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>15</ENT>
              <ENT>5.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>26</ENT>
              <ENT>4.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.40</ENT>
              <ENT>0.092</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>15</ENT>
              <ENT>5.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>26</ENT>
              <ENT>4.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.40</ENT>
              <ENT>0.092</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.246</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55791, Dec. 1, 1975, as amended at 60 FR 33946, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.247</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.242 of this subpart for the best practicable <PRTPAGE P="146"/>control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart Y—Pacific Coast Hand-Shucked Oyster Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55792, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.250</SECTNO>
          <SUBJECT>Applicability; description of the Pacific Coast hand-shucked oyster processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from existing Pacific Coast handshucked oyster processing facilities which process more than 454 kg (1000 lbs) of product per day on any day during a calendar year and all new sources.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.251</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">product</E> shall mean the weight of the oyster meat after shucking.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.252</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>47</ENT>
              <ENT>38</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.4</ENT>
              <ENT>1.8</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>47</ENT>
              <ENT>38</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.4</ENT>
              <ENT>1.8</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55792, Dec. 1, 1975, as amended at 41 FR 31823, July 30, 1976; 60 FR, 33946, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.253</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.254</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55792, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.255</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>45</ENT>
              <ENT>36</ENT>
            </ROW>
            <ROW>
              <PRTPAGE P="147"/>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.2</ENT>
              <ENT>1.7</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>45</ENT>
              <ENT>36</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.2</ENT>
              <ENT>1.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55792, Dec. 1, 1975, as amended at 41 FR 31823, July 30, 1976]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.256</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55792, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.257</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology:</P>
          <GPOTABLE CDEF="s36,10,10" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for thirty consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="n,s,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of product)
              </ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>45</ENT>
              <ENT>36</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.2</ENT>
              <ENT>1.7</ENT>
            </ROW>
            <ROW RUL="n,s,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="n,s,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of product)
              </ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>45</ENT>
              <ENT>36</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.2</ENT>
              <ENT>1.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[51 FR 24998, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart Z—Atlantic and Gulf Coast Hand-Shucked Oyster Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55793, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.260</SECTNO>
          <SUBJECT>Applicability; description of the Atlantic and Gulf Coast hand-shucked oyster processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharge resulting from existing hand-shucked oyster processing facilities on the Atlantic and Gulf Coasts which process more than 454 kg (1000 lbs) of product per day on any day during a calendar year and all new sources.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.261</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">product</E> shall mean the weight of the oyster meat after shucking.</P>
        </SECTION>
        <SECTION>
          <PRTPAGE P="148"/>
          <SECTNO>§ 408.262</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>24</ENT>
              <ENT>16</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.2</ENT>
              <ENT>0.81</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>24</ENT>
              <ENT>16</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.2</ENT>
              <ENT>0.81</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55793, Dec. 1, 1975, as amended at 41 FR 31823, July 30, 1976; 60 FR 33947, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.263</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.264</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">Pretreatment standard</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55793, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.265</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of perform-ance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>23</ENT>
              <ENT>16</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.1</ENT>
              <ENT>0.77</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>23</ENT>
              <ENT>16</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.1</ENT>
              <ENT>0.77</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55793, Dec. 1, 1975, as amended at 41 FR 31824, July 30, 1976]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.266</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">Pretreatment standard</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55793, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <PRTPAGE P="149"/>
          <SECTNO>§ 408.267</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology:</P>
          <GPOTABLE CDEF="s36,10,10" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for thirty consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="n,s,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of product)
              </ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>23</ENT>
              <ENT>16</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.1</ENT>
              <ENT>0.77</ENT>
            </ROW>
            <ROW RUL="n,s,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="n,s,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of product)
              </ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>23</ENT>
              <ENT>16</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.1</ENT>
              <ENT>0.77</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[51 FR 24998, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart AA—Steamed and Canned Oyster Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55794, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.270</SECTNO>
          <SUBJECT>Applicability; description of the steamed and canned oyster processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from oysters which are mechanically shucked.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.271</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">product</E> shall mean the weight of the oyster meat after shucking.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.272</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>270</ENT>
              <ENT>190</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.3</ENT>
              <ENT>1.7</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>270</ENT>
              <ENT>190</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.3</ENT>
              <ENT>1.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55794, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.273</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.274</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <PRTPAGE P="150"/>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55794, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.275</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>Except for those steamed and canned oyster processing facilities which utilize air flotation treatment systems to meet the shrimp processing standards of performance for new sources under §§ 408.115, 408.125, or § 408.135 and for which standards of performance should be derived on a case-by-case basis, the following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>67</ENT>
              <ENT>17</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>56</ENT>
              <ENT>39</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.84</ENT>
              <ENT>0.42</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>67</ENT>
              <ENT>17</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>56</ENT>
              <ENT>39</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>0.64</ENT>
              <ENT>0.42</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55794, Dec. 1, 1975, as amended at 42 FR 6813, Feb. 4, 1977]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.276</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55794, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.277</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.272 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart AB—Sardine Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55795, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.280</SECTNO>
          <SUBJECT>Applicability; description of the sardine processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the canning of sardines or sea herring for sardines. These provisions, however, do not cover the relatively new steaking operation in which cutting machines are used for preparing fish steaks.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.281</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analyses set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <PRTPAGE P="151"/>
          <SECTNO>§ 408.282</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <P>(a) Any sardine processing facility which utilizes dry transportation systems from the fish storage area to the fish processing area shall meet the following limitations:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>36</ENT>
              <ENT>10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>3.5</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>36</ENT>
              <ENT>10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>3.5</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <P>(b) Any sardine processing facility not covered under § 408.282(a) shall meet the following limitations:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>48</ENT>
              <ENT>16</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>6.3</ENT>
              <ENT>2.8</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>48</ENT>
              <ENT>16</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>6.3</ENT>
              <ENT>2.8</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55795, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.283</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.284</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55795, Dec. 1, 1975, as amended at 60 FR 33947, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.285</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>36</ENT>
              <ENT>10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.4</ENT>
              <ENT>0.57</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>36</ENT>
              <ENT>10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>1.4</ENT>
              <ENT>0.57</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <PRTPAGE P="152"/>
          <SECTNO>§ 408.286</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55795, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.287</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.282 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart AC—Alaskan Scallop Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55796, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.290</SECTNO>
          <SUBJECT>Applicability; description of the Alaskan scallop processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of scallops in Alaska.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.291</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">product</E> shall mean the weight of the scallop meat after processing.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.292</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <P>(a) Any Alaskan scallop processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>6.6</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>7.7</ENT>
              <ENT>0.24</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>6.0</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>7.7</ENT>
              <ENT>0.24</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <P>(b) Any Alaskan scallop processing facility not covered under § 408.292(a) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm. (0.5 inch) in any dimension.</P>
          <CITA>[40 FR 55796, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <PRTPAGE P="153"/>
          <SECTNO>§ 408.293</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.294</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55796, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.295</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>(a) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <P>(1) Any Alaskan scallop processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>5.7</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>7.3</ENT>
              <ENT>0.23</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>5.7</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>7.3</ENT>
              <ENT>0.23</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <P>(2) Any Alaskan scallop processing facility not covered under § 408.295(a) (1) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.</P>
          <P>(b) [Reserved]</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.296</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55796, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.297</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.</SUBJECT>
          <P>(a) [Reserved]</P>
          <P>(b) Except as provided in §§ 125.30 through 125.32, any Alaskan scallop processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall achieve the following effluent limitations representing the degreee of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.292(b)(2) of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24998, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <PRTPAGE P="154"/>
        <HD SOURCE="HED">Subpart AD—Non-Alaskan Scallop Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55797, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.300</SECTNO>
          <SUBJECT>Applicability; description of the non-Alaskan scallop processing sub-cat-egory.</SUBJECT>
          <P>With the exception of land-based processing of calico scallops, the provisions of this subpart are applicable to discharges resulting from the processing of scallops outside of Alaska.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.301</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">product</E> shall mean the weight of the scallop meat after processing.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.302</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>6.0</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>7.7</ENT>
              <ENT>0.24</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>6.0</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>7.7</ENT>
              <ENT>0.24</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55797, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.303</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.304</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55797, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.305</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>5.7</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>7.3</ENT>
              <ENT>0.23</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>5.7</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>7.3</ENT>
              <ENT>0.23</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.306</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>

          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned <PRTPAGE P="155"/>treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55797, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.307</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology:</P>
          <GPOTABLE CDEF="s36,10,10" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effuent characteristic</CHED>
              <CHED H="1">Efflluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for thirty consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="03,n,s,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>5.7</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>7.3</ENT>
              <ENT>0.23</ENT>
            </ROW>
            <ROW RUL="n,s,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="n,s,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of product)
              </ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>5.7</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>7.3</ENT>
              <ENT>0.23</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[51 FR 24998, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart AE—Alaskan Herring Fillet Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55798, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.310</SECTNO>
          <SUBJECT>Applicability; description of the Alaskan herring fillet processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of herring fillets in Alaska.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.311</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.312</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <P>(a) Any herring fillet processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak and Petersburg shall meet the following limitations:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>32</ENT>
              <ENT>24</ENT>
            </ROW>
            <ROW>
              <PRTPAGE P="156"/>
              <ENT I="01">Oil and grease</ENT>
              <ENT>27</ENT>
              <ENT>10</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>32</ENT>
              <ENT>24</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>27</ENT>
              <ENT>10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <P>(b) Any Alaskan herring fillet processing facility not covered under § 408.312(a) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.</P>
          <CITA>[40 FR 55798, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.313</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.314</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">Pretreatment standard</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55798, Dec. 1, 1975, as amended at 60 FR 33948, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.315</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>(a) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <P>(1) Any herring fillet processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak and Petersburg shall meet the following limitations:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>23</ENT>
              <ENT>18</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>20</ENT>
              <ENT>7.3</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>23</ENT>
              <ENT>18</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>20</ENT>
              <ENT>7.3</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <P>(2) Any Alaskan herring fillet proc-essing facility not covered under § 408.315(a)(1) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.</P>
          <P>(b) [Reserved]</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.316</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">Pretreatment standard</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55798, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <PRTPAGE P="157"/>
          <SECTNO>§ 408.317</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.312 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart AF—Non-Alaskan Herring Fillet Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55799, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.320</SECTNO>
          <SUBJECT>Applicability; description of the non-Alaskan herring fillet processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of herring fillets outside of Alaska.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.321</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.322</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>32</ENT>
              <ENT>24</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>27</ENT>
              <ENT>10</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>32</ENT>
              <ENT>24</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>27</ENT>
              <ENT>10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55799, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.323</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.324</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55799, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.325</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>

          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:<PRTPAGE P="158"/>
          </P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>16</ENT>
              <ENT>15</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>7.0</ENT>
              <ENT>5.2</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.9</ENT>
              <ENT>1.1</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>16</ENT>
              <ENT>15</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>7.0</ENT>
              <ENT>5.2</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.9</ENT>
              <ENT>1.1</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.326</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55799, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.327</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 408.322 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24997, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart AG—Abalone Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 55800, Dec. 1, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 408.330</SECTNO>
          <SUBJECT>Applicability; description of the abalone processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of abalone in the contiguous states.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.331</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">seafood</E> shall mean the raw material, including freshwater and saltwater fish and shellfish, to be processed, in the form in which it is received at the processing plant.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.332</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>27</ENT>
              <ENT>15</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.2</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <PRTPAGE P="159"/>
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>27</ENT>
              <ENT>15</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.2</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 55800, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.333</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.334</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55800, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.335</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>26</ENT>
              <ENT>14</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.1</ENT>
              <ENT>1.3</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of seafood)
              </ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>26</ENT>
              <ENT>14</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.1</ENT>
              <ENT>1.3</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.336</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 55800, Dec. 1, 1975, as amended at 60 FR 33949, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 408.337</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology.</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, the following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best conventional pollutant control technology:<PRTPAGE P="160"/>
          </P>
          <GPOTABLE CDEF="s36,10,10" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Efflluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for thirty consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="03,n,s,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>26</ENT>
              <ENT>14</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>21</ENT>
              <ENT>1.3</ENT>
            </ROW>
            <ROW RUL="n,s,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="03,n,s,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per 1,000 lb of seafood)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>26</ENT>
              <ENT>14</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>2.1</ENT>
              <ENT>1.3</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <CITA>[51 FR 24999, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
    </PART>
    <PART>
      <EAR>Pt. 409</EAR>
      <HD SOURCE="HED">PART 409—SUGAR PROCESSING POINT SOURCE CATEGORY</HD>
      <CONTENTS>
        <SUBPART>
          <HD SOURCE="HED">Subpart A—Beet Sugar Processing Subcategory</HD>
          <SECHD>Sec.</SECHD>
          <SECTNO>409.10</SECTNO>
          <SUBJECT>Applicability; description of the beet sugar processing subcategory.</SUBJECT>
          <SECTNO>409.11</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>409.12</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>409.13</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.</SUBJECT>
          <SECTNO>409.14</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>409.15</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>409.16</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>409.17</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart B—Crystalline Cane Sugar Refining Subcategory</HD>
          <SECTNO>409.20</SECTNO>
          <SUBJECT>Applicability; description of the crystalline cane sugar refining subcategory.</SUBJECT>
          <SECTNO>409.21</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>409.22</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>409.23</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>409.24</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>409.25</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>409.26</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>409.27</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart C—Liquid Cane Sugar Refining Subcategory</HD>
          <SECTNO>409.30</SECTNO>
          <SUBJECT>Applicability; description of the liquid cane sugar refining subcategory.</SUBJECT>
          <SECTNO>409.31</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>409.32</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>409.33</SECTNO>
          <SUBJECT>[Reserved]</SUBJECT>
          <SECTNO>409.34</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <SECTNO>409.35</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <SECTNO>409.36</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <SECTNO>409.37</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart D—Louisiana Raw Cane Sugar Processing Subcategory</HD>
          <SECTNO>409.40</SECTNO>
          <SUBJECT>Applicability; description of the Louisiana raw cane sugar processing subcategory.</SUBJECT>
          <SECTNO>409.41</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>409.42</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>409.47</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart E—Florida and Texas Raw Cane Sugar Processing Subcategory</HD>
          <SECTNO>409.50</SECTNO>
          <SUBJECT>Applicability; description of the Florida and Texas raw cane sugar processing subcategory.</SUBJECT>
          <SECTNO>409.51</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>409.52</SECTNO>

          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best <PRTPAGE P="161"/>practicable control technology currently available.</SUBJECT>
          <SECTNO>409.57</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart F—Hilo-Hamakua Coast of the Island of Hawaii Raw Cane Sugar Processing Subcategory</HD>
          <SECTNO>409.60</SECTNO>
          <SUBJECT>Applicability; description of the Hilo-Hamakua Coast of the Island of Hawaii raw cane sugar processing sub-cat-egory.</SUBJECT>
          <SECTNO>409.61</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>409.62</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>409.67</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart G—Hawaiian Raw Cane Sugar Processing Subcategory</HD>
          <SECTNO>409.70</SECTNO>
          <SUBJECT>Applicability; description of the Hawaiian raw cane sugar processing sub-cat-egory.</SUBJECT>
          <SECTNO>409.71</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>409.72</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>409.77</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart H—Puerto Rican Raw Cane Sugar Processing Subcategory</HD>
          <SECTNO>409.80</SECTNO>
          <SUBJECT>Applicability; description of the Puerto Rican raw cane sugar processing subcategory.</SUBJECT>
          <SECTNO>409.81</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>409.82</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <SECTNO>409.87</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
        </SUBPART>
      </CONTENTS>
      <AUTH>
        <HD SOURCE="HED">Authority:</HD>
        <P>Secs. 301, 304 (b) and (c), 306 (b) and (c), 307 (c) and (d), and 316(b) of the Federal Water Pollution Control Act, as amended; 33 U.S.C. 1251, 1311, 1314 (b) and (c), 1316 (b) and (c), 1317(c), and 1326(c); 86 Stat. 816 et seq., Pub. L. 92-500; 91 Stat. 1567, Pub. L. 95-217.</P>
      </AUTH>
      <SUBPART>
        <HD SOURCE="HED">Subpart A—Beet Sugar Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>39 FR 4037, Jan. 31, 1974, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 409.10</SECTNO>
          <SUBJECT>Applicability; description of the beet sugar processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from any operation attendant to the processing of sugar beets for the production of sugar.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.11</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) The term <E T="03">barometric condensing operations</E> shall mean those operations or processes directly associated with or related to the concentration and crystallization of sugar solutions.</P>
          <P>(c) The term <E T="03">product</E> shall mean crystallized refined sugar.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.12</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best practicable control technology currently available; provided however, that a discharge by a point source may be made in accordance with the limitations set forth in either paragraph (a) of this section exclusively, or paragraph (b) of this section exclusively, below:</P>

          <P>(a) The following limitations establish the maximum permissible discharge of process waste water pollutants when the process waste water discharge results from barometric condensing operations only.<PRTPAGE P="162"/>
          </P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>3.3</ENT>
              <ENT>2.2</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">Temperature</ENT>
              <ENT>(<SU>2</SU>)</ENT>
              <ENT>(<SU>2</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>3.3</ENT>
              <ENT>2.2</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Temperature</ENT>
              <ENT>(<SU>3</SU>)</ENT>
              <ENT>(<SU>3</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
            <TNOTE>
              <SU>2</SU> Temperature not to exceed the temperature of cooled water acceptable for return to the heat producing process and in no event greater than 32 °C.</TNOTE>
            <TNOTE>
              <SU>3</SU> Temperature not to exceed the temperature of cooled water acceptable for return to the heat producing process and in no event greater than 90 °F.</TNOTE>
          </GPOTABLE>
          <P>(b) The following limitations establish the maximum permissible discharge of process waste water pollutants when the process waste water discharge results, in whole or in part, from barometric condensing operations and any other beet sugar processing operation.</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>3.3</ENT>
              <ENT>2.2</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>3.3</ENT>
              <ENT>2.2</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Fecal coliform</ENT>
              <ENT>(<SU>2</SU>)</ENT>
              <ENT>(<SU>2</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">Temperature</ENT>
              <ENT>(<SU>3</SU>)</ENT>
              <ENT>(<SU>3</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of product)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>3.3</ENT>
              <ENT>2.2</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>3.3</ENT>
              <ENT>2.2</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Fecal coliform</ENT>
              <ENT>(<SU>4</SU>)</ENT>
              <ENT>(<SU>4</SU>)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Temperature</ENT>
              <ENT>(<SU>5</SU>)</ENT>
              <ENT>(<SU>5</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
            <TNOTE>
              <SU>2</SU> Not to exceed MPN of 400/100 ml at any time.</TNOTE>
            <TNOTE>
              <SU>3</SU> Not to exceed 32 °F.</TNOTE>
            <TNOTE>
              <SU>4</SU> Not to exceed MPN of 400/100 ml at any time (not typically expressed in English units).</TNOTE>
            <TNOTE>
              <SU>5</SU> Not to exceed 90 °F.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.13</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.</SUBJECT>
          <P>(a) The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source where the sugar beet processing capacity of the point source does not exceed 1090 kkg (2300 tons) per day of beets sliced or where the soil filtration rate, whether natural or by deliberate design, within the boundaries of all waste water treatment or retention facilities associated with the point source is less than or equal to 0.159 cm (<FR>1/16</FR> in.) per day; provided however, that a discharge by a point source may be made in accordance with the limitations set forth in either paragraph (a)(1) exclusively, or paragraph (a)(2) of this section exclusively.</P>
          <P>(1) The following limitations establish the maximum permissible discharge of process waste water pollutants when the process waste water discharge results from barometric condensing operations only.</P>
          <GPOTABLE CDEF="s40,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">Temperature</ENT>
              <ENT>Temperature not to exceed the temperature of cooled water acceptable for return to the heat producing process and in no event greater than 32 °C (90 °F).</ENT>
            </ROW>
          </GPOTABLE>
          <P>(2) The following limitations establish the maximum permissible discharge of process waste water pollutants when the process waste water discharge results, in whole or in part, from barometric condensing operations and any other beet sugar processing operation.</P>
          <GPOTABLE CDEF="s40,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">Effluent characteristics</CHED>
              <CHED H="1">Effluent limitations</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">Temperature</ENT>
              <ENT>Not to exceed 32 °C (90 °F).</ENT>
            </ROW>
          </GPOTABLE>
          <P>(b) [Reserved]</P>
          <CITA>[39 FR 4037, Jan. 31, 1974, as amended at 40 FR 36337, Aug. 20, 1975; 44 FR 50740, Aug. 29, 1979]</CITA>
        </SECTION>
        <SECTION>
          <PRTPAGE P="163"/>
          <SECTNO>§ 409.14</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Fecal coliform</ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Temperature (heat)</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6439, Feb. 11, 1975, as amended at 60 FR 33949, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.15</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart: There shall be no discharge of process waste water pollutants to navigable waters.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.16</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33949, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.17</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 409.12 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24999, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart B—Crystalline Cane Sugar Refining Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>39 FR 10524, Mar. 20, 1974, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 409.20</SECTNO>
          <SUBJECT>Applicability; description of the crystalline cane sugar refining subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of raw cane sugar into crystalline refined sugar.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.21</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) Net shall mean the addition of pollutants.</P>
          <P>(c) Melt shall mean that amount of raw material (raw sugar) contained within aqueous solution at the beginning of the process for production of refined cane sugar.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.22</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) Any crystalline cane sugar refinery discharging both barometric condenser cooling water and other process waters shall meet the following limitations. The BOD<E T="03">5</E> limitation is determined by the addition of the net BOD<E T="03">5</E> attributed to the barometric condenser cooling water to that amount of BOD<E T="03">5</E> attributed to the treated process water. The TSS limitation is that <PRTPAGE P="164"/>amount of TSS attributed to the treated process water. Where the barometric condenser cooling water and process water streams are mixed and impossible to measure separately prior to discharge, the values should be considered net.</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of melt)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.19</ENT>
              <ENT>0.43</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>.27</ENT>
              <ENT>0.09</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per ton of melt)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>2.38</ENT>
              <ENT>0.86</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>.54</ENT>
              <ENT>.18</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <P>(b) Any crystalline cane sugar refinery discharging barometric condenser cooling water only should be required to achieve the following net limitations:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of melt)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.02</ENT>
              <ENT>0.34</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per ton of melt)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>2.04</ENT>
              <ENT>0.68</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[39 FR 10524, Mar. 20, 1974, as amended at 60 FR 33949, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.23</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.24</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6440, Feb. 11, 1975, as amended at 60 FR 33949, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.25</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of melt)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.18</ENT>
              <ENT>0.09</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>.11</ENT>
              <ENT>.035</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per ton of melt)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.36</ENT>
              <ENT>0.18</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>.21</ENT>
              <ENT>.07</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.26</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33950, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.27</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall <PRTPAGE P="165"/>achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 409.22 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24999, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart C—Liquid Cane Sugar Refining Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>39 FR 10526, Mar. 20, 1974, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 409.30</SECTNO>
          <SUBJECT>Applicability; description of the liquid cane sugar refining subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of raw cane sugar into liquid refined sugar.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.31</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.</P>
          <P>(b) Net shall mean the addition of pollutants.</P>
          <P>(c) Melt shall mean that amount of raw material (raw sugar) contained within aqueous solution at the beginning of the process for production of refined cane sugar.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.32</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) Any liquid cane sugar refinery discharging both barometric condenser cooling water and other process waters shall meet the following limitations. The BOD<E T="03">5</E> limitation is determined by the addition of the net BOD<E T="03">5</E> attributed to the barometric condenser cooling water to that amount of BOD<E T="03">5</E> attributed to the treated process water. The TSS limitation is that amount of TSS attributed to the treated process water. Where the barometric condenser cooling water and process water streams are mixed and impossible to measure separately prior to discharge, the values should be considered net.</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of melt)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.78</ENT>
              <ENT>0.32</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>.50</ENT>
              <ENT>.17</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per ton of melt)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.56</ENT>
              <ENT>0.63</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>.99</ENT>
              <ENT>.33</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
          <P>(b) Any liquid cane sugar refinery discharging barometric condenser cooling water only shall meet the following net limitations:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of melt)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.45</ENT>
              <ENT>0.15</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per ton of melt)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.90</ENT>
              <ENT>0.30</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[39 FR 10526, Mar. 20, 1974, as amended at 60 FR 33950, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.33</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.34</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources.</SUBJECT>

          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned <PRTPAGE P="166"/>treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.</P>
          <GPOTABLE CDEF="s80,r55" COLS="2" OPTS="L2">
            <BOXHD>
              <CHED H="1">
                <E T="01">Pollutant or pollutant property</E>
              </CHED>
              <CHED H="1">
                <E T="01">Pretreatment standard</E>
              </CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>No limitation.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>Do.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>Do.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 6440, Feb. 11, 1975, as amended at 60 FR 33950, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.35</SECTNO>
          <SUBJECT>Standards of performance for new sources.</SUBJECT>
          <P>The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kilograms per 1,000 kg of melt)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.30</ENT>
              <ENT>0.15</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.09</ENT>
              <ENT>.03</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (pounds per ton of melt)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.60</ENT>
              <ENT>0.30</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.18</ENT>
              <ENT>.06</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.36</SECTNO>
          <SUBJECT>Pretreatment standards for new sources.</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
          <CITA>[60 FR 33950, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.37</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 409.32 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24999, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart D—Louisiana Raw Cane Sugar Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 8503, Feb. 27, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 409.40</SECTNO>
          <SUBJECT>Applicability; description of the Louisiana raw cane sugar processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of sugar cane into a raw sugar product for those cane sugar factories operating in the State of Louisiana.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.41</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">gross cane</E> shall mean that amount of crop material as harvested, including field trash and other extraneous material.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.42</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall <PRTPAGE P="167"/>achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) Any cane sugar factory continuously discharging both barometric condenser cooling water and other process waste waters shall meet the following limitations. The BOD<E T="03">5</E> limitation is determined by the addition of the net BOD<E T="03">5</E> attributable to the barometric condenser cooling water to that amount of BOD<E T="03">5</E> attributable to the treated process waste water. The TSS limitation is that amount of TSS attributable to the treated process waste water, excluding barometric condenser cooling water.</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of gross cane)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.14</ENT>
              <ENT>0.63</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.41</ENT>
              <ENT>0.47</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of gross cane)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.14</ENT>
              <ENT>0.63</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.41</ENT>
              <ENT>0.47</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(b) Any cane sugar factory employing waste stabilization where all or a portion of the waste water discharge is stored for the entire grinding season shall meet the following limitations. The BOD<E T="03">5</E> limitation is determined by the addition of the net BOD<E T="03">5</E> attributable to the barometric condenser cooling water to that amount of BOD<E T="03">5</E> attributable to the treated process waste water. The TSS limitation is that amount of TSS attributable to the treated process waste water, excluding barometric condenser cooling water.</P>
          <GPOTABLE CDEF="xs65,r70" COLS="2" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations, the total of the daily values for the entire discharge period shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT O="oi0">Metric units (kg/kkg of gross cane)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.63.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.47.</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>Within the range 6.0 to 9.0.</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT O="oi0">English units (lb/1,000 lb of gross cane)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.63.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.47.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Within the range 6.0 to 9.0.</ENT>
            </ROW>
          </GPOTABLE>
          <CITA>[40 FR 8503, Feb. 27, 1975, as amended at 60 FR 33950, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.47</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 409.42 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24999, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart E—Florida and Texas Raw Cane Sugar Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 8503, Feb. 27, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 409.50</SECTNO>
          <SUBJECT>Applicability; description of the Florida and Texas raw cane sugar processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of sugar cane into a raw sugar product for those cane sugar factories located in the states of Florida and Texas.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.51</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) [Reserved]</P>
        </SECTION>
        <SECTION>
          <PRTPAGE P="168"/>
          <SECTNO>§ 409.52</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, and subject to the provisions of paragraph (a) of this section, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): There shall be no discharge of process wastewater pollutants to navigable waters.</P>
          <P>(a) Process waste water pollutants in the overflow may be discharged to navigable waters whenever rainfall events cause an overflow of process waste water from a facility designed, constructed, and operated to contain all process generated waste waters.</P>
          <P>(b) [Reserved]</P>
          <CITA>[60 FR 33950, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.57</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 409.52 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24999, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart F—Hilo-Hamakua Coast of the Island of Hawaii Raw Cane Sugar Processing Subcategory</HD>
        <SECTION>
          <SECTNO>§ 409.60</SECTNO>
          <SUBJECT>Applicability; description of the Hilo-Hamakua Coast of the Island of Hawaii raw cane sugar processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of sugar cane into a raw sugar product for those cane sugar factories located on the Hilo-Hamakua Coast of the Island of Hawaii in the State of Hawaii.</P>
          <CITA>[40 FR 8504, Feb. 27, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.61</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">gross cane</E> shall mean that amount of crop material as harvested, including field trash and other extraneous material.</P>
          <P>(c) The term <E T="03">net cane</E> shall mean that amount of “gross cane” less the weight of extraneous material.</P>
          <P>(d) The term <E T="03">x</E> shall mean that fraction of the “net cane” harvested by the advanced harvesting systems.</P>
          <CITA>[40 FR 8504, Feb. 27, 1975]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.62</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):<PRTPAGE P="169"/>
          </P>
          <GPOTABLE CDEF="xs50,xl15,xl20,xl15,r20" COLS="5" OPTS="L2">
            <BOXHD>
              <CHED H="1">Effluent characteristics</CHED>
              <CHED H="1">Maximum for any 1 day</CHED>
              <CHED H="2">kg/kkg gross cane</CHED>
              <CHED H="2">lb/1,000 lb gross cane</CHED>
              <CHED H="1">Average of daily values for 30 consecutive days shall not exceed</CHED>
              <CHED H="2">kg/kkg gross cane</CHED>
              <CHED H="2">lb/1,000 lb gross cane</CHED>
            </BOXHD>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>).</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>9.9</ENT>
              <ENT>9.9</ENT>
              <ENT>3.6</ENT>
              <ENT>3.6.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>).</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> No limitations.</TNOTE>
          </GPOTABLE>
          <CITA>[40 FR 8504, Feb 27, 1975, as amended at 44 FR 64080, Nov. 6, 1979; 45 FR 59152, Sept. 8, 1980; 60 FR 33950, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.67</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 409.62 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24999, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart G—Hawaiian Raw Cane Sugar Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 8504, Feb. 27, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <SECTNO>§ 409.70</SECTNO>
          <SUBJECT>Applicability; description of the Hawaiian raw cane sugar processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of sugar cane into a raw sugar product for those cane sugar factories, other than those described by subpart F, located in the State of Hawaii.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.71</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.72</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, and subject to the provisions of paragraph (a) of this section, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): There shall be no discharge of process waste water pollutants to navigable waters.</P>
          <P>(a) Process waste water pollutants in the overflow may be discharged to navigable waters whenever rainfall events cause an overflow of process waste water from a facility designed, constructed, and operated to contain all process generated waste waters.</P>
          <P>(b) [Reserved]</P>
          <CITA>[40 FR 8504, Feb. 27, 1975, as amended at 60 FR 33950, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.77</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 409.72 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24999, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart H—Puerto Rican Raw Cane Sugar Processing Subcategory</HD>
        <SOURCE>
          <HD SOURCE="HED">Source:</HD>
          <P>40 FR 8505, Feb. 27, 1975, unless otherwise noted.</P>
        </SOURCE>
        <SECTION>
          <PRTPAGE P="170"/>
          <SECTNO>§ 409.80</SECTNO>
          <SUBJECT>Applicability; description of the Puerto Rican raw cane sugar processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to discharges resulting from the processing of sugar cane into a raw sugar product for those cane sugar factories located on the island of Puerto Rico.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.81</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>For the purpose of this subpart:</P>
          <P>(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.</P>
          <P>(b) The term <E T="03">gross cane</E> shall mean that amount of crop material as harvested, including field trash and other extraneous material.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.82</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.</SUBJECT>
          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>

          <P>(a) Any cane sugar factory continuously discharging both barometric condenser cooling water and other process waste waters shall meet the following limitations. The BOD<E T="03">5</E> limitation is determined by the addition of the net BOD<E T="03">5</E> attributable to the barometric condenser cooling water to that amount of BOD<E T="03">5</E> attributable to the treated process waste water. The TSS limitation is that amount of TSS attributable to the treated process waste water, excluding barometric condenser cooling water.</P>
          <GPOTABLE CDEF="s25,9,14" COLS="3" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Metric units (kg/kkg of gross cane)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.14</ENT>
              <ENT>0.63</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.41</ENT>
              <ENT>0.47</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">English units (lb/1,000 lb of gross cane)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.14</ENT>
              <ENT>0.63</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.41</ENT>
              <ENT>0.47</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>)</ENT>
              <ENT>(<SU>1</SU>)</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0.</TNOTE>
          </GPOTABLE>

          <P>(b) Any cane sugar factory employing waste stabilization where all or a portion of the waste water discharge is stored for the entire grinding season shall meet the following limitations. The BOD<E T="03">5</E> limitation is determined by the addition of the net BOD<E T="03">5</E> attributable to the barometric condenser cooling water to that amount of BOD<E T="03">5</E> attributable to the treated process waste water. The TSS limitation is that amount of TSS attributable to the treated process waste water, excluding barometric condenser cooling water.</P>
          <GPOTABLE CDEF="xs65,r70" COLS="2" OPTS="L1">
            <BOXHD>
              <CHED H="1">Effluent characteristic</CHED>
              <CHED H="1">Effluent limitations, the total of the daily values for the entire discharge period shall not exceed—</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT O="oi0">Metric units (kg/kkg of gross cane)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.63.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.47.</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="01">pH</ENT>
              <ENT>Within the range 6.0 to 9.0.</ENT>
            </ROW>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT O="oi0">English units (lb/1,000 lb of gross cane)</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>0.63.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>0.47.</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>Within the range 6.0 to 9.0.</ENT>
            </ROW>
          </GPOTABLE>
          <SECAUTH>(Secs. 301, 304 (b) and (c), 306 (b) and (c), 307 (c) and (d) of the Federal Water Pollution Control Act, as amended (33 U.S.C. 1251, 1311, 1314 (b) and (c), 1316 (b) and (c), 1317(c) and 1326(c)), 86 Stat. 816 et seq., Pub. L. 92-500)</SECAUTH>
          <CITA>[40 FR 8504, Feb. 27, 1975, as amended at 60 FR 33950, June 29, 1995]</CITA>
        </SECTION>
        <SECTION>
          <SECTNO>§ 409.87</SECTNO>
          <SUBJECT>Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SUBJECT>

          <P>Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall <PRTPAGE P="171"/>achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations shall be the same as those specified for conventional pollutants (which are defined in § 401.16) in § 409.82 of this subpart for the best practicable control technology currently available (BPT).</P>
          <CITA>[51 FR 24999, July 9, 1986]</CITA>
        </SECTION>
      </SUBPART>
    </PART>
    <PART>
      <EAR>Pt. 410</EAR>
      <HD SOURCE="HED">PART 410—TEXTILE MILLS POINT SOURCE CATEGORY</HD>
      <CONTENTS>
        <SUBJGRP>
          <HD SOURCE="HED">General Provisions</HD>
          <SECHD>Sec.</SECHD>
          <SECTNO>410.00</SECTNO>
          <SUBJECT>Applicability.</SUBJECT>
          <SECTNO>410.01</SECTNO>
          <SUBJECT>General definitions.</SUBJECT>
          <SECTNO>410.02</SECTNO>
          <SUBJECT>Monitoring requirements. [Reserved]</SUBJECT>
        </SUBJGRP>
        <SUBPART>
          <HD SOURCE="HED">Subpart A—Wool Scouring Subcategory</HD>
          <SECTNO>410.10</SECTNO>
          <SUBJECT>Applicability; description of the wool scouring subcategory.</SUBJECT>
          <SECTNO>410.11</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>410.12</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).</SUBJECT>
          <SECTNO>410.13</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).</SUBJECT>
          <SECTNO>410.14</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources (PSES).</SUBJECT>
          <SECTNO>410.15</SECTNO>
          <SUBJECT>New source performance standards (NSPS).</SUBJECT>
          <SECTNO>410.16</SECTNO>
          <SUBJECT>Pretreatment standards for new sources (PSNS).</SUBJECT>
          <SECTNO>410.17</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). [Reserved]</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart B—Wool Finishing Subcategory</HD>
          <SECTNO>410.20</SECTNO>
          <SUBJECT>Applicability; description of the wool finishing subcategory.</SUBJECT>
          <SECTNO>410.21</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>410.22</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).</SUBJECT>
          <SECTNO>410.23</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).</SUBJECT>
          <SECTNO>410.24</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources (PSES).</SUBJECT>
          <SECTNO>410.25</SECTNO>
          <SUBJECT>New source performance standards (NSPS).</SUBJECT>
          <SECTNO>410.26</SECTNO>
          <SUBJECT>Pretreatment standards for new sources (PSNS).</SUBJECT>
          <SECTNO>410.27</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). [Reserved]</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart C—Low Water Use Processing Subcategory</HD>
          <SECTNO>410.30</SECTNO>
          <SUBJECT>Applicability; description of the low water use processing subcategory.</SUBJECT>
          <SECTNO>410.31</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>410.32</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).</SUBJECT>
          <SECTNO>410.33</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).</SUBJECT>
          <SECTNO>410.34</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources (PSES).</SUBJECT>
          <SECTNO>410.35</SECTNO>
          <SUBJECT>New source performance standards (NSPS).</SUBJECT>
          <SECTNO>410.36</SECTNO>
          <SUBJECT>Pretreatment standards for new sources (PSNS).</SUBJECT>
          <SECTNO>410.37</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). [Reserved]</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart D—Woven Fabric Finishing Subcategory</HD>
          <SECTNO>410.40</SECTNO>
          <SUBJECT>Applicability; description of the woven fabric finishing subcategory.</SUBJECT>
          <SECTNO>410.41</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>410.42</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).</SUBJECT>
          <SECTNO>410.43</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).</SUBJECT>
          <SECTNO>410.44</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources (PSES).</SUBJECT>
          <SECTNO>410.45</SECTNO>
          <SUBJECT>New source performance standards (NSPS).</SUBJECT>
          <SECTNO>410.46</SECTNO>
          <SUBJECT>Pretreatment standards for new sources (PSNS).</SUBJECT>
          <SECTNO>410.47</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). [Reserved]</SUBJECT>
        </SUBPART>
        <SUBPART>
          <PRTPAGE P="172"/>
          <HD SOURCE="HED">Subpart E—Knit Fabric Finishing Subcategory</HD>
          <SECTNO>410.50</SECTNO>
          <SUBJECT>Applicability; description of the knit fabric finishing subcategory.</SUBJECT>
          <SECTNO>410.51</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>410.52</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).</SUBJECT>
          <SECTNO>410.53</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).</SUBJECT>
          <SECTNO>410.54</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources (PSES).</SUBJECT>
          <SECTNO>410.55</SECTNO>
          <SUBJECT>New source performance standards (NSPS).</SUBJECT>
          <SECTNO>410.56</SECTNO>
          <SUBJECT>Pretreatment standards for new sources (PSNS).</SUBJECT>
          <SECTNO>410.57</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). [Reserved]</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart F—Carpet Finishing Subcategory</HD>
          <SECTNO>410.60</SECTNO>
          <SUBJECT>Applicability; description of the carpet finishing subcategory.</SUBJECT>
          <SECTNO>410.61</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <SECTNO>410.62</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).</SUBJECT>
          <SECTNO>410.63</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).</SUBJECT>
          <SECTNO>410.64</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources (PSES).</SUBJECT>
          <SECTNO>410.65</SECTNO>
          <SUBJECT>New source performance standards (NSPS).</SUBJECT>
          <SECTNO>410.66</SECTNO>
          <SUBJECT>Pretreatment standards for new sources (PSNS).</SUBJECT>
          <SECTNO>410.67</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). [Reserved]</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart G—Stock and Yarn Finishing Subcategory</HD>
          <SECTNO>410.70</SECTNO>
          <SUBJECT>Applicability; description of the stock and yarn finishing subcategory.</SUBJECT>
          <SECTNO>410.71</SECTNO>
          <SUBJECT>Specialized definitions. [Reserved]</SUBJECT>
          <SECTNO>410.72</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).</SUBJECT>
          <SECTNO>410.73</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).</SUBJECT>
          <SECTNO>410.74</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources (PSES).</SUBJECT>
          <SECTNO>410.75</SECTNO>
          <SUBJECT>New source performance standards (NSPS).</SUBJECT>
          <SECTNO>410.76</SECTNO>
          <SUBJECT>Pretreatment standards for new sources (PSNS).</SUBJECT>
          <SECTNO>410.77</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). [Reserved]</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart H—Nonwoven Manufacturing Subcategory</HD>
          <SECTNO>410.80</SECTNO>
          <SUBJECT>Applicability; description of the nonwoven manufacturing subcategory.</SUBJECT>
          <SECTNO>410.81</SECTNO>
          <SUBJECT>Specialized definitions. [Reserved]</SUBJECT>
          <SECTNO>410.82</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).</SUBJECT>
          <SECTNO>410.83</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).</SUBJECT>
          <SECTNO>410.84</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources (PSES).</SUBJECT>
          <SECTNO>410.85</SECTNO>
          <SUBJECT>New source performance standards (NSPS).</SUBJECT>
          <SECTNO>410.86</SECTNO>
          <SUBJECT>Pretreatment standards for new sources (PSNS).</SUBJECT>
          <SECTNO>410.87</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). [Reserved]</SUBJECT>
        </SUBPART>
        <SUBPART>
          <HD SOURCE="HED">Subpart I—Felted Fabric Processing Subcategory</HD>
          <SECTNO>410.90</SECTNO>
          <SUBJECT>Applicability; description of the felted fabric processing subcategory.</SUBJECT>
          <SECTNO>410.91</SECTNO>
          <SUBJECT>Specialized definitions. [Reserved]</SUBJECT>
          <SECTNO>410.92</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).</SUBJECT>
          <SECTNO>410.93</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).</SUBJECT>
          <SECTNO>410.94</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources (PSES).</SUBJECT>
          <SECTNO>410.95</SECTNO>
          <SUBJECT>New source performance standards (NSPS).</SUBJECT>
          <SECTNO>410.96</SECTNO>

          <SUBJECT>Pretreatment standards for new sources (PSNS).<PRTPAGE P="173"/>
          </SUBJECT>
          <SECTNO>410.97</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). [Reserved]</SUBJECT>
        </SUBPART>
      </CONTENTS>
      <AUTH>
        <HD SOURCE="HED">Authority:</HD>
        <P>Secs. 301, 304 (b), (c), (e), and (g), 306 (b) and (c), 307 (b) and (c), and 501 of the Clean Water Act (the Federal Water Pollution Control Act Amendments of 1972, as amended by the Clean Water Act of 1977) (the “Act”); 33 U.S.C. 1311, 1314 (b), (c), (e), and (g), 1316 (b) and (c), 1317 (b) and (c), and 1361; 86 Stat. 186 et seq., Pub. L. 92-500; 91 Stat. 1567, Pub. L. 95-217.</P>
      </AUTH>
      <SOURCE>
        <HD SOURCE="HED">Source:</HD>
        <P>47 FR 38819, Sept. 2, 1982, unless otherwise noted.</P>
      </SOURCE>
      <SUBJGRP>
        <HD SOURCE="HED">General Provisions</HD>
        <SECTION>
          <SECTNO>§ 410.00</SECTNO>
          <SUBJECT>Applicability.</SUBJECT>
          <P>This part applies to any textile mill or textile processing facility which discharges or may discharge process wastewater pollutants to the waters of the United States, or which introduces or may introduce process wastewater pollutants into a publicly owned treatment works.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.01</SECTNO>
          <SUBJECT>General definitions.</SUBJECT>
          <P>In addition to the definitions set forth in 40 CFR part 401, the following definitions apply to this part:</P>
          <P>(a) <E T="03">Sulfide</E> shall mean total sulfide (dissolved and acid soluble) as measured by the procedures listed in 40 CFR part 136.</P>
          <P>(b) <E T="03">Phenols</E> shall mean total phenols as measured by the procedure listed in 40 CFR part 136.</P>
          <P>(c) Total Chromium shall mean hexavalent and trivalent chromium as measured by the procedures listed in 40 CFR part 136.</P>
          <P>(d) The term <E T="03">commission finishing</E> shall mean the finishing of textile materials, 50 percent or more of which are owned by others, in mills that are 51 percent or more independent (i.e., only a minority ownership by company(ies) with greige or integrated operations); the mills must process 20 percent or more of their commissioned production through batch, noncontinuous processing operations with 50 percent or more of their commissioned orders processed in 5000 yard or smaller lots.</P>
          <P>(e) The term <E T="03">product,</E> except where a specialized definition is included in the subpart, shall mean the final material produced or processed at the mill.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.02</SECTNO>
          <SUBJECT>Monitoring requirements. [Reserved]</SUBJECT>
        </SECTION>
      </SUBJGRP>
      <SUBPART>
        <HD SOURCE="HED">Subpart A—Wool Scouring Subcategory</HD>
        <SECTION>
          <SECTNO>§ 410.10</SECTNO>
          <SUBJECT>Applicability; description of the wool scouring subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to process wastewater discharges resulting from the following types of textile mills: wool scouring, topmaking, and general cleaning of raw wool.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.11</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>In addition to the definitions set forth in 40 CFR part 401 and § 410.01 of this part, the following definitions apply to this subpart:</P>
          <P>(a) The term <E T="03">wool</E> shall mean the dry raw wool as it is received by the wool scouring mill.</P>
          <P>(b) The term <E T="03">oil and grease</E> shall mean total recoverable oil and grease as measured by the procedure listed in 40 CFR part 136.</P>
          <P>(c) The term <E T="03">commission scouring</E> shall mean the scouring of wool, 50 percent or more of which is owned by others, in mills that are 51 percent or more independent (i.e., only a minority ownership by company(ies) with greige or integrated operations); the mills must process 20 percent or more of their commissioned production through batch, noncontinuous processing operations.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.12</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).</SUBJECT>

          <P>(a) Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):<PRTPAGE P="174"/>
          </P>
          <GPOTABLE CDEF="s25,8.2,8.2" COLS="3" OPTS="L2">
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">BPT limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days</CHED>
            </BOXHD>
            <ROW RUL="03,n,s">
              <ENT I="11"/>
              <ENT A="01">Kg/kkg (or pounds per 1,000 lb) of wool</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>10.6</ENT>
              <ENT>5.3</ENT>
            </ROW>
            <ROW>
              <ENT I="01">COD</ENT>
              <ENT>138.0</ENT>
              <ENT>69.0</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>32.2</ENT>
              <ENT>16.1</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Oil and grease</ENT>
              <ENT>7.2</ENT>
              <ENT>3.6</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Sulfide</ENT>
              <ENT>0.20</ENT>
              <ENT>0.10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Phenol</ENT>
              <ENT>0.10</ENT>
              <ENT>0.05</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Total chromium</ENT>
              <ENT>0.10</ENT>
              <ENT>0.05</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU> )</ENT>
              <ENT>(<SU>1</SU> )</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0 at all times.</TNOTE>
          </GPOTABLE>
          <P>(b) Additional allocations equal to the effluent limitations established in paragraph (a) of this section are allowed any existing point source subject to such effluent limitations that scours wool through “commission scouring” as defined in § 410.11.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.13</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).</SUBJECT>
          <P>(a) Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT):</P>
          <GPOTABLE CDEF="s25,8.2,8.2" COLS="3" OPTS="L2,tp4">
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">BAT limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days</CHED>
            </BOXHD>
            <ROW RUL="03,n,s">
              <ENT I="11"/>
              <ENT A="01">Kg/kkg (or pounds per 1,000 lb) of wool</ENT>
            </ROW>
            <ROW>
              <ENT I="01">COD</ENT>
              <ENT>138.0</ENT>
              <ENT>69.0</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Sulfide</ENT>
              <ENT>0.20</ENT>
              <ENT>0.10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Phenols</ENT>
              <ENT>0.10</ENT>
              <ENT>0.05</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Total chromium</ENT>
              <ENT>0.10</ENT>
              <ENT>0.05</ENT>
            </ROW>
          </GPOTABLE>
          <P>(b) Additional allocations equal to the effluent limitations established in paragraph (a) of this section are allowed any existing point source subject to such effluent limitations that scours wool through “commission scouring” as defined in § 410.11.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.14</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources (PSES).</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.15</SECTNO>
          <SUBJECT>New source performance standards (NSPS).</SUBJECT>
          <P>Any new source subject to this subpart must achieve the following new source performance standards (NSPS):</P>
          <GPOTABLE CDEF="s25,8.2,8.2" COLS="3" OPTS="L2,tp4">
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">NSPS</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days</CHED>
            </BOXHD>
            <ROW RUL="03,n,s">
              <ENT I="11"/>
              <ENT A="01">Kg/kkg (or pounds per 1,000 lb) of wool</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>3.6</ENT>
              <ENT>1.9</ENT>
            </ROW>
            <ROW>
              <ENT I="01">COD</ENT>
              <ENT>52.4</ENT>
              <ENT>33.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>30.3</ENT>
              <ENT>13.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Sulfide</ENT>
              <ENT>0.20</ENT>
              <ENT>0.10</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Phenols</ENT>
              <ENT>0.10</ENT>
              <ENT>0.05</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Total chromium</ENT>
              <ENT>0.10</ENT>
              <ENT>0.05</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU> )</ENT>
              <ENT>(<SU>1</SU> )</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0 at all times.</TNOTE>
            <TNOTE>Note: <E T="01">Additional allocations for “commission scouring” are not available to new sources.</E>
            </TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.16</SECTNO>
          <SUBJECT>Pretreatment standards for new sources (PSNS).</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.17</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). [Reserved]</SUBJECT>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart B—Wool Finishing Subcategory</HD>
        <SECTION>
          <SECTNO>§ 410.20</SECTNO>
          <SUBJECT>Applicability; description of the wool finishing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to process wastewater discharges resulting from the following types of textile mills: wool finishers, including carbonizing, fulling, dyeing, bleaching, rinsing, fireproofing, and other such similar processes.</P>
        </SECTION>
        <SECTION>
          <PRTPAGE P="175"/>
          <SECTNO>§ 410.21</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>In addition to the definitions set forth in 40 CFR part 401 and § 410.01 of this part, the following definition applies to this subpart:</P>
          <P>(a) The term <E T="03">fiber</E> shall mean the dry wool and other fibers as received at the wool finsihing mill for processing into wool and blended products.</P>
          <P>(b) [Reserved]</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.22</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).</SUBJECT>
          <P>(a) Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):</P>
          <GPOTABLE CDEF="s25,8.2,8.2" COLS="3" OPTS="L2,tp4">
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">BPT limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days</CHED>
            </BOXHD>
            <ROW RUL="n,s">
              <ENT I="11"/>
              <ENT A="01">Kg/kkg (or pound per 1,000 lb) of fiber
              </ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>22.4</ENT>
              <ENT>11.2</ENT>
            </ROW>
            <ROW>
              <ENT I="01">COD</ENT>
              <ENT>163.0</ENT>
              <ENT>81.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>35.2</ENT>
              <ENT>17.6</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Sulfide</ENT>
              <ENT>0.28</ENT>
              <ENT>0.14</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Phenol</ENT>
              <ENT>0.14</ENT>
              <ENT>0.07</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Total chromium</ENT>
              <ENT>0.14</ENT>
              <ENT>0.07</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU> )</ENT>
              <ENT>(<SU>1</SU> )</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0 at all times.</TNOTE>
          </GPOTABLE>
          <P>(b) Additional allocations equal to the effluent limitations established in paragraph (a) of this section are allowed any existing point source subject to such effluent limitations that finishes wool or blended wool fabrics through “commission finishing” as defined in § 410.01.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.23</SECTNO>
          <SUBJECT>Effluent limitation representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).</SUBJECT>
          <P>(a) Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT):</P>
          <GPOTABLE CDEF="s25,8.2,8.2" COLS="3" OPTS="L2,tp4">
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">BAT limitation</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days</CHED>
            </BOXHD>
            <ROW RUL="n,s">
              <ENT I="11"/>
              <ENT A="01">Kg/kkg (or pounds per 1,000 lb) of fiber
              </ENT>
            </ROW>
            <ROW>
              <ENT I="01">COD</ENT>
              <ENT>163.0</ENT>
              <ENT>81.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Sulfide</ENT>
              <ENT>0.28</ENT>
              <ENT>0.14</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Phenols</ENT>
              <ENT>0.14</ENT>
              <ENT>0.07</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Total Chromium</ENT>
              <ENT>0.14</ENT>
              <ENT>0.07</ENT>
            </ROW>
          </GPOTABLE>
          <P>(b) Additional allocations equal to the effluent limitations established in paragraph (a) of this section are allowed any existing point source subject to such effluent limitations that finishes wool or blended wool fabrics through “commission finishing” as defined in § 410.01.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.24</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources (PSES).</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.25</SECTNO>
          <SUBJECT>New source performance standards (NSPS).</SUBJECT>
          <P>Any new source subject to this subpart must achieve the following new source performance standards (NSPS):</P>
          <GPOTABLE CDEF="s25,8.2,8.2" COLS="3" OPTS="L2,tp4">
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">NSPS</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days</CHED>
            </BOXHD>
            <ROW RUL="03,n,s">
              <ENT I="11"/>
              <ENT A="01">Kg/kkg (pounds per 1,000 lb) of fiber</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>10.7</ENT>
              <ENT>5.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">COD</ENT>
              <ENT>113.8</ENT>
              <ENT>73.3</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>32.3</ENT>
              <ENT>14.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Sulfide</ENT>
              <ENT>0.28</ENT>
              <ENT>0.14</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Phenols</ENT>
              <ENT>0.14</ENT>
              <ENT>0.07</ENT>
            </ROW>
            <ROW>
              <ENT I="01">Total Chromium</ENT>
              <ENT>0.14</ENT>
              <ENT>0.07</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU> )</ENT>
              <ENT>(<SU>1</SU> )</ENT>
            </ROW>
            <TNOTE>Note: Additional allocations for “commission finishers” are not available to new sources.</TNOTE>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0 at all times.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <PRTPAGE P="176"/>
          <SECTNO>§ 410.26</SECTNO>
          <SUBJECT>Pretreatment standards for new sources (PSNS).</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.27</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). [Reserved]</SUBJECT>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart C—Low Water Use Processing Subcategory</HD>
        <SECTION>
          <SECTNO>§ 410.30</SECTNO>
          <SUBJECT>Applicability; description of the low water use processing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to process wastewater discharges resulting from the following types of textile mills: yarn manufacture, yarn texturizing, unfinished fabric manufacture, fabric coating, fabric laminating, tire cord and fabric dipping, and carpet tufting and carpet backing. Rubberized or rubber coated fabrics regulated by 40 CFR part 428 are specifically excluded.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.31</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>In addition to the definitions set forth in 40 CFR part 401 and § 410.01 of this part, the following definitions apply to this subpart:</P>
          <P>(a) The term <E T="03">general processing</E> shall mean the internal subdivision of the low water use processing subcategory for facilities described in § 410.30 that do not qualify under the water jet weaving subdivision.</P>
          <P>(b) The term <E T="03">water jet weaving</E> shall mean the internal subdivision of the low water use processing subcategory for facilities primarily engaged in manufacturing woven greige goods through the water jet weaving process.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.32</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).</SUBJECT>
          <P>Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BPT):</P>
          <GPOTABLE CDEF="s25,9.1,9.1" COLS="3" OPTS="L2">
            <TTITLE>
              <E T="04">General Processing</E>
            </TTITLE>
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">BPT limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days</CHED>
            </BOXHD>
            <ROW RUL="03,n,s">
              <ENT I="11"/>
              <ENT A="01">Kg/kkg (pounds per 1,000 lb) of product</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>1.4</ENT>
              <ENT>0.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">COD</ENT>
              <ENT>2.8</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.4</ENT>
              <ENT>0.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">ph</ENT>
              <ENT>(<SU>1</SU> )</ENT>
              <ENT>(<SU>1</SU> )</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0 at all times.</TNOTE>
          </GPOTABLE>
          <GPOTABLE CDEF="s25,9.1,9.1" COLS="3" OPTS="L2">
            <TTITLE>
              <E T="04">Water Jet Weaving</E>
            </TTITLE>
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">BPT limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days</CHED>
            </BOXHD>
            <ROW RUL="03,n,s">
              <ENT I="11"/>
              <ENT A="01">Kg/kkg (pounds per 1,000 1lb) of product</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>8.9</ENT>
              <ENT>4.6</ENT>
            </ROW>
            <ROW>
              <ENT I="01">COD</ENT>
              <ENT>21.3</ENT>
              <ENT>13.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>5.5</ENT>
              <ENT>2.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">ph</ENT>
              <ENT>(<SU>1</SU> )</ENT>
              <ENT>(<SU>1</SU> )</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0 at all times.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.33</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).</SUBJECT>
          <P>Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT):</P>
          <GPOTABLE CDEF="s25,9.1,9.1" COLS="3" OPTS="L2">
            <TTITLE>
              <E T="04">General Processing</E>
            </TTITLE>
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">BAT limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Kg/kkg (pounds per 1,000 lb) of product</ENT>
            </ROW>
            <ROW>
              <ENT I="01">COD</ENT>
              <ENT>2.8</ENT>
              <ENT>1.4</ENT>
            </ROW>
          </GPOTABLE>
          <PRTPAGE P="177"/>
          <GPOTABLE CDEF="s25,9.1,9.1" COLS="3" OPTS="L2">
            <TTITLE>
              <E T="04">Water Jet Weaving</E>
            </TTITLE>
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">BAT limitations</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Kg/kkg (pounds per 1,000 lb) of product</ENT>
            </ROW>
            <ROW>
              <ENT I="01">COD</ENT>
              <ENT>21.3</ENT>
              <ENT>13.7</ENT>
            </ROW>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.34</SECTNO>
          <SUBJECT>Pretreatment standards for existing sources (PSES).</SUBJECT>
          <P>Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.35</SECTNO>
          <SUBJECT>New source performance standards (NSPS).</SUBJECT>
          <P>Any new source subject to this subpart must achieve the following new source performance standards (NSPS):</P>
          <GPOTABLE CDEF="s25,9.1,9.1" COLS="3" OPTS="L2">
            <TTITLE>
              <E T="04">General Processing</E>
            </TTITLE>
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">NSPS</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Kg/kkg (pounds per 1,000 lb) of product</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">\5\</E>
              </ENT>
              <ENT>1.4</ENT>
              <ENT>0.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">COD</ENT>
              <ENT>2.8</ENT>
              <ENT>1.4</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>1.4</ENT>
              <ENT>0.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU>  )</ENT>
              <ENT>(<SU>1</SU>  )</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0 at all times.</TNOTE>
          </GPOTABLE>
          <GPOTABLE CDEF="s25,9.1,9.1" COLS="3" OPTS="L2">
            <TTITLE>
              <E T="04">Water Jet Weaving</E>
            </TTITLE>
            <BOXHD>
              <CHED H="1">Pollutant or pollutant property</CHED>
              <CHED H="1">NSPS</CHED>
              <CHED H="2">Maximum for any 1 day</CHED>
              <CHED H="2">Average of daily values for 30 consecutive days</CHED>
            </BOXHD>
            <ROW RUL="02,n,s">
              <ENT I="11"/>
              <ENT A="01">Kg/kkg (pounds per 1,000 lb) of product</ENT>
            </ROW>
            <ROW>
              <ENT I="01">BOD<E T="03">5</E>
              </ENT>
              <ENT>8.9</ENT>
              <ENT>4.6</ENT>
            </ROW>
            <ROW>
              <ENT I="01">COD</ENT>
              <ENT>21.3</ENT>
              <ENT>13.7</ENT>
            </ROW>
            <ROW>
              <ENT I="01">TSS</ENT>
              <ENT>5.5</ENT>
              <ENT>2.5</ENT>
            </ROW>
            <ROW>
              <ENT I="01">pH</ENT>
              <ENT>(<SU>1</SU> )</ENT>
              <ENT>(<SU>1</SU> )</ENT>
            </ROW>
            <TNOTE>
              <SU>1</SU> Within the range 6.0 to 9.0 at all times.</TNOTE>
          </GPOTABLE>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.36</SECTNO>
          <SUBJECT>Pretreatment standards for new sources (PSNS).</SUBJECT>
          <P>Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.37Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT).</SECTNO>
          <RESERVED>[Reserved]</RESERVED>
        </SECTION>
      </SUBPART>
      <SUBPART>
        <HD SOURCE="HED">Subpart D—Woven Fabric Finishing Subcategory</HD>
        <SECTION>
          <SECTNO>§ 410.40</SECTNO>
          <SUBJECT>Applicability; description of the woven fabric finishing subcategory.</SUBJECT>
          <P>The provisions of this subpart are applicable to process wastewater discharges resulting from the following types of textile mills: woven fabric finishers, which may include any or all of the following unit operations: Desizing, bleaching, mercerizing, dyeing, printing, resin treatment, water proofing, flame proofing, soil repellency application and a special finish application.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.41</SECTNO>
          <SUBJECT>Specialized definitions.</SUBJECT>
          <P>In addition to the definitions set forth in 40 CFR part 401 and § 410.01 of this part the following definitions apply to this subpart:</P>
          <P>(a) The term <E T="03">simple manufacturing operation</E> shall mean all the following unit processes: Desizing, fiber preparation and dyeing.</P>
          <P>(b) The term <E T="03">complex manufacturing operation</E> shall mean “simple” unit processes (desizing, fiber preparation and dyeing) plus any additional manufacturing operations such as printing, water proofing, or applying stain resistance or other functional fabric finishes.</P>
          <P>(c) For NSPS (§ 410.45) the term <E T="03">desizing facilities</E> shall mean those facilities that desize more than 50 percent of their total production. These facilities may also perform other processing such as fiber preparation, scouring, mercerizing, functional finishing, bleaching, dyeing and printing.</P>
        </SECTION>
        <SECTION>
          <SECTNO>§ 410.42</SECTNO>
          <SUBJECT>Effluent limitations representing the degree of effluent reduction attainable by the application of the best pra