    <TITLE>Recordkeeping requirements.</TITLE>
    <GRANULENUM>63.454</GRANULENUM>
    <HEADING>Section 63.454</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="2">AIR PROGRAMS (Continued)</PARENT>
      <PARENT HEADING="PART 63" SEQ="1">NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES</PARENT>
      <PARENT HEADING="Subpart S" SEQ="0">National Emission Standards for Hazardous Air Pollutants from the Pulp and Paper Industry</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 63.454</SECTNO>
    <SUBJECT>Recordkeeping requirements.</SUBJECT>
    <P>(a) The owner or operator of each affected source subject to the requirements of this subpart shall comply with the recordkeeping requirements of § 63.10 of subpart A of this part, as shown in table 1, and the requirements specified in paragraphs (b) through (d) of this section for the monitoring parameters specified in § 63.453.</P>
    <P>(b) For each applicable enclosure opening, closed-vent system, and closed collection system, the owner or operator shall prepare and maintain a site-specific inspection plan including a drawing or schematic of the components of applicable affected equipment and shall record the following information for each inspection:</P>
    <P>(1) Date of inspection;</P>
    <P>(2) The equipment type and identification;</P>
    <P>(3) Results of negative pressure tests for enclosures;</P>
    <P>(4) Results of leak detection tests;</P>
    <P>(5) The nature of the defect or leak and the method of detection (i.e., visual inspection or instrument detection);</P>
    <P>(6) The date the defect or leak was detected and the date of each attempt to repair the defect or leak;</P>
    <P>(7) Repair methods applied in each attempt to repair the defect or leak;</P>
    <P>(8) The reason for the delay if the defect or leak is not repaired within 15 days after discovery;</P>
    <P>(9) The expected date of successful repair of the defect or leak if the repair is not completed within 15 days;</P>
    <P>(10) The date of successful repair of the defect or leak;</P>
    <P>(11) The position and duration of opening of bypass line valves and the condition of any valve seals; and</P>
    <P>(12) The duration of the use of bypass valves on computer controlled valves.</P>
    <P>(c) The owner or operator of a bleaching system complying with § 63.440(d)(3)(ii)(B) shall record the daily average chlorine and hypochlorite application rates, in kg of bleaching agent per megagram of ODP, of the bleaching system until the requirements specified in § 63.440(d)(3)(ii)(A) are met.</P>
    <P>(d) The owner or operator shall record the CMS parameters specified in § 63.453 and meet the requirements specified in paragraph (a) of this section for any new affected process equipment or pulping process condensate stream that becomes subject to the standards in this subpart due to a process change or modification.</P>