<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>47</CFRTITLE>
    <CFRTITLETEXT>Telecommunication</CFRTITLETEXT>
    <VOL>5</VOL>
    <DATE>2000-10-01</DATE>
    <ORIGINALDATE>2000-10-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Special requirements for automatically generating the radiotelephone alarm signal.</TITLE>
    <GRANULENUM>80.221</GRANULENUM>
    <HEADING>Section 80.221</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 47" SEQ="4">Telecommunication</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">FEDERAL COMMUNICATIONSCOMMISSION (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER D" SEQ="2">SAFETY AND SPECIAL RADIO SERVICES</PARENT>
      <PARENT HEADING="PART 80" SEQ="1">STATIONS IN THE MARITIME SERVICES</PARENT>
      <PARENT HEADING="Subpart E" SEQ="0">General Technical Standards</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 80.221</SECTNO>
    <SUBJECT>Special requirements for automatically generating the radiotelephone alarm signal.</SUBJECT>
    <P>(a) Each device for automatically generating the radiotelephone alarm signal must be capable of being disabled to permit the immediate transmission of a distress call and message.</P>
    <P>(b) The device must comply with the following requirements:</P>
    <P>(1) The frequency tolerance of each tone must be <E T="61">±</E>1.5 percent;</P>
    <P>(2) The duration tolerance of each tone must be <E T="61">±</E>50 milliseconds;</P>
    <P>(3) The interval between successive tones must not exceed 50 milliseconds; and</P>
    <P>(4) The amplitude ratio of the tones must be flat within 1.6 dB.</P>
    <P>(c) Devices installed on or after January 1, 1983, must comply with the following requirements:</P>
    <P>(1) The frequency tolerance of each tone must be <E T="61">±</E>1.5 percent;</P>
    <P>(2) The duration tolerance of each tone must be <E T="61">±</E>10 milliseconds;</P>
    <P>(3) The interval between successive tones must not exceed 4 milliseconds;</P>
    <P>(4) The amplitude ratio of the tones must be flat within 1.6 dB;</P>
    <P>(5) The output of the device must be sufficient to modulate the associated transmitter for H2B emission to at least 70 percent, and for J2B emission to within 3 dB of the rated peak envelope power;</P>
    <P>(6) Light from the device must not interfere with the safe navigation of the ship;</P>
    <P>(7) After activation the device must automatically generate the radiotelephone alarm signal for not less than 30 seconds and not more than 60 seconds unless manually interrupted;</P>
    <P>(8) After generating the radiotelephone alarm signal or after manual interruption the device must be immediately ready to repeat the signal;</P>
    <P>(9) The transmitter must be automatically switched from the stand-by condition to the transmit condition at the start and return to the stand-by condition at the conclusion of the radiotelephone alarm signal.</P>
    <P>(d) Any device used by a station to automatically generate the radiotelephone alarm signal must be certificated by the Commission.</P>
    <CITA>[51 FR 31213, Sept. 2, 1986, as amended at 54 FR 40059, Sept. 29, 1989; 63 FR 36606, July 7, 1998]</CITA>
  </SECTION>