    <TITLE>Design factor (F) for steel pipe.</TITLE>
    <GRANULENUM>192.111</GRANULENUM>
    <HEADING>Section 192.111</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 49" SEQ="4">Transportation</PARENT>
      <PARENT HEADING="Subtitle B" SEQ="3">Other Regulations Relating to Transportation-Continued</PARENT>
      <PARENT HEADING="SUBCHAPTER D" SEQ="2">PIPELINE SAFETY</PARENT>
      <PARENT HEADING="PART 192" SEQ="1">TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS</PARENT>
      <PARENT HEADING="Subpart C" SEQ="0">Pipe Design</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 192.111</SECTNO>
    <SUBJECT>Design factor (<E T="03">F</E>
      <E T="02">) for steel pipe.</E>
    </SUBJECT>
    <P>(a) Except as otherwise provided in paragraphs (b), (c), and (d) of this section, the design factor to be used in the design formula in § 192.105 is determined in accordance with the following table:</P>
    <GPOTABLE CDEF="s50,9" COLS="2" OPTS="L2">
      <BOXHD>
        <CHED H="1">Class location</CHED>
        <CHED H="1">Design factor (<E T="03">F</E>)</CHED>
      </BOXHD>
      <ROW>
        <ENT I="01">1</ENT>
        <ENT>0.72</ENT>
      </ROW>
      <ROW>
        <ENT I="01">2</ENT>
        <ENT>0.60</ENT>
      </ROW>
      <ROW>
        <ENT I="01">3</ENT>
        <ENT>0.50</ENT>
      </ROW>
      <ROW>
        <ENT I="01">4</ENT>
        <ENT>0.40</ENT>
      </ROW>
    </GPOTABLE>
    <P>(b) A design factor of 0.60 or less must be used in the design formula in § 192.105 for steel pipe in Class 1 locations that:</P>
    <P>(1) Crosses the right-of-way of an unimproved public road, without a casing;</P>
    <P>(2) Crosses without a casing, or makes a parallel encroachment on, the right-of-way of either a hard surfaced road, a highway, a public street, or a railroad;</P>
    <P>(3) Is supported by a vehicular, pedestrian, railroad, or pipeline bridge; or</P>
    <P>(4) Is used in a fabricated assembly, (including separators, mainline valve assemblies, cross-connections, and river crossing headers) or is used within five pipe diameters in any direction from the last fitting of a fabricated assembly, other than a transition piece or an elbow used in place of a pipe bend which is not associated with a fabricated assembly.</P>
    <P>(c) For Class 2 locations, a design factor of 0.50, or less, must be used in the design formula in § 192.105 for uncased steel pipe that crosses the right-of-way of a hard surfaced road, a highway, a public street, or a railroad.</P>
    <P>(d) For Class 1 and Class 2 locations, a design factor of 0.50, or less, must be used in the design formula in § 192.105 for—</P>
    <P>(1) Steel pipe in a compressor station, regulating station, or measuring station; and</P>
    <P>(2) Steel pipe, including a pipe riser, on a platform located offshore or in inland navigable waters.</P>
    <CITA>[35 FR 13257, Aug. 19, 1970, as amended by Amdt. 192-27, 41 FR 34605, Aug. 16, 1976]</CITA>