<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>49</CFRTITLE>
    <CFRTITLETEXT>Transportation</CFRTITLETEXT>
    <VOL>3</VOL>
    <DATE>2002-10-01</DATE>
    <ORIGINALDATE>2002-10-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Pipeline location.</TITLE>
    <GRANULENUM>195.210</GRANULENUM>
    <HEADING>Section 195.210</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 49" SEQ="4">Transportation</PARENT>
      <PARENT HEADING="Subtitle B" SEQ="3">Other Regulations Relating to Transportation (Continued)</PARENT>
      <PARENT HEADING="SUBCHAPTER D" SEQ="2">PIPELINE SAFETY</PARENT>
      <PARENT HEADING="PART 195" SEQ="1">TRANSPORTATION OF HAZARDOUS LIQUIDS BY PIPELINE</PARENT>
      <PARENT HEADING="Subpart D" SEQ="0">Construction</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 195.210</SECTNO>
    <SUBJECT>Pipeline location.</SUBJECT>
    <P>(a) Pipeline right-of-way must be selected to avoid, as far as practicable, areas containing private dwellings, industrial buildings, and places of public assembly.</P>
    <P>(b) No pipeline may be located within 50 feet (15 meters) of any private dwelling, or any industrial building or place of public assembly in which persons work, congregate, or assemble, unless it is provided with at least 12 inches (305 millimeters) of cover in addition to that prescribed in § 195.248.</P>
    <CITA>[Amdt. 195-22, 46 FR 39360, July 27, 1981, as amended by Amdt. 195-63, 63 FR 37506, July 13, 1998]</CITA>
  </SECTION>
</CFRGRANULE>