<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>23</VOL>
    <DATE>2003-07-01</DATE>
    <ORIGINALDATE>2003-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Standards: Open-ended valves or lines.</TITLE>
    <GRANULENUM>265.1056</GRANULENUM>
    <HEADING>Section 265.1056</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER I" SEQ="2">SOLID WASTES (CONTINUED)</PARENT>
      <PARENT HEADING="PART 265" SEQ="1">INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES</PARENT>
      <PARENT HEADING="Subpart BB" SEQ="0">Air Emission Standards for Equipment Leaks</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 265.1056</SECTNO>
    <SUBJECT>Standards: Open-ended valves or lines.</SUBJECT>
    <P>(a)(1) Each open-ended valve or line shall be equipped with a cap, blind flange, plug, or a second valve.</P>
    <P>(2) The cap, blind flange, plug, or second valve shall seal the open end at all times except during operations requiring hazardous waste stream flow through the open-ended valve or line.</P>
    <P>(b) Each open-ended valve or line equipped with a second valve shall be operated in a manner such that the valve on the hazardous waste stream end is closed before the second valve is closed.</P>
    <P>(c) When a double block and bleed system is being used, the bleed valve or line may remain open during operations that require venting the line between the block valves but shall comply with paragraph (a) of this section at all other times.</P>
  </SECTION>