<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>26</VOL>
    <DATE>2003-07-01</DATE>
    <ORIGINALDATE>2003-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Pretreatment standards for new sources (PSNS).</TITLE>
    <GRANULENUM>415.86</GRANULENUM>
    <HEADING>Section 415.86</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER N" SEQ="2">EFFLUENT GUIDELINES AND STANDARDS</PARENT>
      <PARENT HEADING="PART 415" SEQ="1">INORGANIC CHEMICALS MANUFACTURING POINT SOURCE CATEGORY</PARENT>
      <PARENT HEADING="Subpart H" SEQ="0">Hydrofluoric Acid Production Subcategory</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 415.86</SECTNO>
    <SUBJECT>Pretreatment standards for new sources (PSNS).</SUBJECT>
    <P>Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following Pretreatment Standards for New Sources (PSNS):</P>
    <GPOTABLE CDEF="s60,5.3,5.3" COLS="3" OPTS="L2">
      <TTITLE>Subpart H—Hydrofluoric Acid</TTITLE>
      <BOXHD>
        <CHED H="1">Pollutant or pollutant property</CHED>
        <CHED H="1">PSNS effluent limitations</CHED>
        <CHED H="2">Maximum for any 1 day</CHED>
        <CHED H="2">Average of daily values for 30 consecutive days</CHED>
      </BOXHD>
      <ROW RUL="03,n,s">
        <ENT I="11"/>
        <ENT A="01">Milligrams per liter</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Fluoride (T)</ENT>
        <ENT>100</ENT>
        <ENT>50</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Nickel (T)</ENT>
        <ENT>0.66</ENT>
        <ENT>0.20</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Zinc (T)</ENT>
        <ENT>2.2</ENT>
        <ENT>0.66</ENT>
      </ROW>
    </GPOTABLE>
    <FP>In cases where POTWs find it necessary to impose mass limitations, the following equivalent mass limitations are provided as an alternate: The limitations for Fluoride (T), Nickel (T), and Zinc (T) are the same as specified in § 415.85.</FP>
    <CITA>[47 FR 55226, Dec. 8, 1982]</CITA>
  </SECTION>