<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>26</VOL>
    <DATE>2003-07-01</DATE>
    <ORIGINALDATE>2003-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Pretreatment standards for new sources (PSNS).</TITLE>
    <GRANULENUM>419.27</GRANULENUM>
    <HEADING>Section 419.27</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER N" SEQ="2">EFFLUENT GUIDELINES AND STANDARDS</PARENT>
      <PARENT HEADING="PART 419" SEQ="1">PETROLEUM REFINING POINT SOURCE CATEGORY</PARENT>
      <PARENT HEADING="Subpart B" SEQ="0">Cracking Subcategory</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 419.27</SECTNO>
    <SUBJECT>Pretreatment standards for new sources (PSNS).</SUBJECT>

    <P>Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must <PRTPAGE P="368"/>comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources (PSNS).</P>
    <P>(a) The following standards apply to the total refinery flow contribution to the POTW.</P>
    <GPOTABLE CDEF="s50,10" COLS="2" OPTS="L2,tp2">
      <BOXHD>
        <CHED H="1">Pollutant or pollutant property</CHED>
        <CHED H="1">Pretreatment standards for new sources—maximum for any 1 day</CHED>
      </BOXHD>
      <ROW RUL="s">
        <ENT I="11"/>
        <ENT O="oi1">Milligrams per liter (mg/l)</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Oil and grease</ENT>
        <ENT>100</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Ammonia (as N)</ENT>
        <ENT>
          <SU>1</SU> 100</ENT>
      </ROW>
      <TNOTE>
        <SU>1</SU> Where the discharge to the POTW consists solely of sour waters, the owner or operator has the option of complying with this limit or the daily maximum mass limitation for ammonia set forth in § 419.26(a) and (b).</TNOTE>
    </GPOTABLE>
    <P>(b) The following standard is applied to the cooling tower discharge part of the total refinery flow to the POTW by multiplying: (1) The standard; (2) by the total refinery flow to the POTW; and (3) by the ratio of the cooling tower discharge flow to the total refinery flow.</P>
    <GPOTABLE CDEF="s50,10" COLS="2" OPTS="L2,tp2">
      <BOXHD>
        <CHED H="1">Pollutant or pollutant property</CHED>
        <CHED H="1">Pretreatment standards for new sources—maximum for any 1 day</CHED>
      </BOXHD>
      <ROW RUL="03,n,s">
        <ENT I="11"/>
        <ENT O="oi1">Milligrams per liter (mg/l)</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Total chromium</ENT>
        <ENT>1</ENT>
      </ROW>
    </GPOTABLE>
  </SECTION>
</CFRGRANULE>