<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>27</VOL>
    <DATE>2003-07-01</DATE>
    <ORIGINALDATE>2003-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Frequency of monitoring.</TITLE>
    <GRANULENUM>503.16</GRANULENUM>
    <HEADING>Section 503.16</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER O" SEQ="2">SEWAGE SLUDGE</PARENT>
      <PARENT HEADING="PART 503" SEQ="1">STANDARDS FOR THE USE OR DISPOSAL OF SEWAGE SLUDGE</PARENT>
      <PARENT HEADING="Subpart B" SEQ="0">Land Application</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 503.16</SECTNO>
    <SUBJECT>Frequency of monitoring.</SUBJECT>
    <P>(a) <E T="03">Sewage sludge.</E> (1) The frequency of monitoring for the pollutants listed in Table 1, Table 2, Table 3 and Table 4 of § 503.13; the pathogen density requirements in § 503.32(a) and § 503.32(b)(2); and the vector attraction reduction requirements in § 503.33 (b)(1) through (b)(4) and § 503.33 (b)(7) through (b)(8) shall be the frequency in Table 1 of § 503.16.</P>
    <GPOTABLE CDEF="s100,xs160" COLS="2" OPTS="L2,i1">
      <TTITLE>Table 1 of § 503.16—Frequency of Monitoring—Land Application</TTITLE>
      <BOXHD>
        <CHED H="1">Amount of sewage sludge <SU>1</SU> (metric tons per 365 day period)</CHED>
        <CHED H="1">Frequency</CHED>
      </BOXHD>
      <ROW>
        <ENT I="01">Greater than zero but less than 290</ENT>
        <ENT>Once per year.</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Equal to or greater than 290 but less than 1,500</ENT>
        <ENT>Once per quarter (four times per year).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Equal to or greater than 1,500 but less than 15,000</ENT>
        <ENT>Once per 60 days (six times per year).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Equal to or greater than 15,000</ENT>
        <ENT>Once per month (12 times per year).</ENT>
      </ROW>
      <TNOTE>
        <SU>1</SU> Either the amount of bulk sewage sludge applied to the land or the amount of sewage sludge prepared for sale or give-away in a bag or other container for application to the land (dry weight basis).</TNOTE>
    </GPOTABLE>
    <PRTPAGE P="831"/>
    <P>(2) After the sewage sludge has been monitored for two years at the frequency in Table 1 of § 503.16, the permitting authority may reduce the frequency of monitoring for pollutant concentrations and for the pathogen density requirements in § 503.32(a)(5)(ii) and (a)(5)(iii).</P>
    <P>(b) <E T="03">Domestic septage.</E> If either the pathogen requirements in § 503.32(c)(2) or the vector attraction reduction requirements in § 503.33(b)(12) are met when domestic septage is applied to agricultural land, forest, or a reclamation site, each container of domestic septage applied to the land shall be monitored for compliance with those requirements.</P>
    <APPRO>(Approved by the Office of Management and Budget under control number 2040-0157)</APPRO>
    <CITA>[58 FR 9387, Feb. 19, 1993, as amended at 64 FR 42569, Aug. 4, 1999]</CITA>
  </SECTION>
</CFRGRANULE>