    <TITLE>Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air respirators; test requirements.</TITLE>
    <GRANULENUM>84.162</GRANULENUM>
    <HEADING>Section 84.162</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 42" SEQ="4">Public Health</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES</PARENT>
      <PARENT HEADING="SUBCHAPTER G" SEQ="2">OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES</PARENT>
      <PARENT HEADING="PART 84" SEQ="1">APPROVAL OF RESPIRATORY PROTECTIVE DEVICES</PARENT>
      <PARENT HEADING="Subpart J" SEQ="0">Supplied-Air Respirators</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 84.162</SECTNO>
    <SUBJECT>Man test for gases and vapors; Type C respirators, continuous-flow class and Type CE supplied-air respirators; test requirements.</SUBJECT>
    <P>(a) The completely assembled respirator will be worn in a chamber containing 0.1±0.025 percent isoamyl acetate vapor, the intake of the hose will be connected to a suitable source of respirable air, and not more than 25 percent of the hose length will be located in isoamyl acetate-free air.</P>
    <P>(b) The minimum flow of air required to maintain a positive pressure in the respiratory-inlet covering throughout the entire breathing cycle will be supplied to the wearer, provided however, that airflow shall not be less than 115 liters per minute for tight-fitting and not less than 170 liters per minute for loose-fitting respiratory inlet-coverings.</P>
    <P>(c) The test will be repeated with the maximum rate of flow attainable within specified operating pressures.</P>