<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>42</CFRTITLE>
    <CFRTITLETEXT>Public Health</CFRTITLETEXT>
    <VOL>1</VOL>
    <DATE>2004-10-01</DATE>
    <ORIGINALDATE>2004-10-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Tables to Subpart L of Part 84</TITLE>
    <GRANULENUM/>
    <ANCESTORS>
      <PARENT HEADING="Title 42" SEQ="5">Public Health</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="4">PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES</PARENT>
      <PARENT HEADING="SUBCHAPTER G" SEQ="3">OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES</PARENT>
      <PARENT HEADING="PART 84" SEQ="2">APPROVAL OF RESPIRATORY PROTECTIVE DEVICES</PARENT>
      <PARENT HEADING="Subpart L" SEQ="1">Chemical Cartridge Respirators</PARENT>
      <PARENT HEADING="Section 84.207" SEQ="0">Bench tests; gas and vapor tests; minimum requirements; general.</PARENT>
    </ANCESTORS>
  </FDSYS>
  <APPENDIX>
    <EAR>Pt. 84, Subpt. L, Tables</EAR>
    <HD SOURCE="HED">Tables to Subpart L of Part 84</HD>
    <GPOTABLE CDEF="s25,r25,xls40,10,10,10,10,10" COLS="8" OPTS="L2">
      <TTITLE>Tables 9-10 [Reserved]</TTITLE>
      <TTITLE>Table 11—Cartridge Bench Tests and Requirements</TTITLE>
      <TDESC>[42 CFR part 84, subpart L]</TDESC>
      <BOXHD>
        <CHED H="1">Cartridge</CHED>
        <CHED H="1">Test condition</CHED>
        <CHED H="1">Test atmosphere</CHED>
        <CHED H="2">Gas or vapor</CHED>
        <CHED H="2">Concentration (p.p.m.)</CHED>
        <CHED H="1">Flowrate (l.p.m.)</CHED>
        <CHED H="1">Number of tests</CHED>
        <CHED H="1">Penetration <SU>1</SU> (p.p.m.)</CHED>
        <CHED H="1">Minimum life <SU>2</SU> (min.)</CHED>
      </BOXHD>
      <ROW>
        <ENT I="01">Ammonia</ENT>
        <ENT>As received</ENT>
        <ENT>NH<E T="52">3</E>
        </ENT>
        <ENT>1000</ENT>
        <ENT>64</ENT>
        <ENT>3</ENT>
        <ENT>50</ENT>
        <ENT>50</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Ammonia</ENT>
        <ENT>Equilibrated</ENT>
        <ENT>NH<E T="52">3</E>
        </ENT>
        <ENT>1000</ENT>
        <ENT>32</ENT>
        <ENT>4</ENT>
        <ENT>50</ENT>
        <ENT>50</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Chlorine</ENT>
        <ENT>As received</ENT>
        <ENT>Cl<E T="52">2</E>
        </ENT>
        <ENT>500</ENT>
        <ENT>64</ENT>
        <ENT>3</ENT>
        <ENT>5</ENT>
        <ENT>35</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Chlorine</ENT>
        <ENT>Equilibrated</ENT>
        <ENT>Cl<E T="52">2</E>
        </ENT>
        <ENT>500</ENT>
        <ENT>32</ENT>
        <ENT>4</ENT>
        <ENT>5</ENT>
        <ENT>35</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Hydrogen chloride</ENT>
        <ENT>As received</ENT>
        <ENT>HCl</ENT>
        <ENT>500</ENT>
        <ENT>64</ENT>
        <ENT>3</ENT>
        <ENT>5</ENT>
        <ENT>50</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Hydrogen chloride</ENT>
        <ENT>Equilibrated</ENT>
        <ENT>HCl</ENT>
        <ENT>500</ENT>
        <ENT>32</ENT>
        <ENT>4</ENT>
        <ENT>5</ENT>
        <ENT>50</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Methylamine</ENT>
        <ENT>As received</ENT>
        <ENT>CH<E T="52">3</E> NH<E T="52">2</E>
        </ENT>
        <ENT>1000</ENT>
        <ENT>64</ENT>
        <ENT>3</ENT>
        <ENT>10</ENT>
        <ENT>25</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Methylamine</ENT>
        <ENT>Equilibrated</ENT>
        <ENT>CH<E T="52">3</E> NH<E T="52">2</E>
        </ENT>
        <ENT>1000</ENT>
        <ENT>32</ENT>
        <ENT>4</ENT>
        <ENT>10</ENT>
        <ENT>25</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Organic vapors</ENT>
        <ENT>As received</ENT>
        <ENT>CCl<E T="52">4</E>
        </ENT>
        <ENT>1000</ENT>
        <ENT>64</ENT>
        <ENT>3</ENT>
        <ENT>5</ENT>
        <ENT>50</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Organic vapors</ENT>
        <ENT>Equilibrated</ENT>
        <ENT>CCl<E T="52">4</E>
        </ENT>
        <ENT>1000</ENT>
        <ENT>32</ENT>
        <ENT>4</ENT>
        <ENT>5</ENT>
        <ENT>50</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Sulfur dioxide</ENT>
        <ENT>As received</ENT>
        <ENT>SO<E T="52">2</E>
        </ENT>
        <ENT>500</ENT>
        <ENT>64</ENT>
        <ENT>3</ENT>
        <ENT>5</ENT>
        <ENT>30</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Sulfur dioxide</ENT>
        <ENT>Equilibrated</ENT>
        <ENT>SO<E T="52">2</E>
        </ENT>
        <ENT>500</ENT>
        <ENT>32</ENT>
        <ENT>4</ENT>
        <ENT>5</ENT>
        <ENT>30</ENT>
      </ROW>
      <TNOTE>
        <SU>1</SU> Minimum life will be determined at the indicated penetration.</TNOTE>
      <TNOTE>
        <SU>2</SU> Where a respirator is designed for respiratory protection against more than one type of gas or vapor, as for use in ammonia and in chlorine, the minimum life shall be one-half that shown for each type of gas or vapor. Where a respirator is designed for respiratory protection against more than one gas of a type, as for use in chlorine and sulfur dioxide, the stated minimal life shall apply.</TNOTE>
    </GPOTABLE>
  </APPENDIX>
</CFRGRANULE>