<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>49</CFRTITLE>
    <CFRTITLETEXT>Transportation</CFRTITLETEXT>
    <VOL>3</VOL>
    <DATE>2004-10-01</DATE>
    <ORIGINALDATE>2004-10-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Service lines: Plastic.</TITLE>
    <GRANULENUM>192.375</GRANULENUM>
    <HEADING>Section 192.375</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 49" SEQ="4">Transportation</PARENT>
      <PARENT HEADING="Subtitle B" SEQ="3">Other Regulations Relating to Transportation (Continued)</PARENT>
      <PARENT HEADING="SUBCHAPTER D" SEQ="2">PIPELINE SAFETY</PARENT>
      <PARENT HEADING="PART 192" SEQ="1">TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS</PARENT>
      <PARENT HEADING="Subpart H" SEQ="0">Customer Meters, Service Regulators, and Service Lines</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <PRTPAGE P="65"/>
    <SECTNO>§ 192.375</SECTNO>
    <SUBJECT>Service lines: Plastic.</SUBJECT>
    <P>(a) Each plastic service line outside a building must be installed below ground level, except that—</P>
    <P>(1) It may be installed in accordance with § 192.321(g); and</P>
    <P>(2) It may terminate above ground level and outside the building, if—</P>
    <P>(i) The above ground level part of the plastic service line is protected against deterioration and external damage; and</P>
    <P>(ii) The plastic service line is not used to support external loads.</P>
    <P>(b) Each plastic service line inside a building must be protected against external damage.</P>