<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>6</VOL>
    <DATE>2005-07-01</DATE>
    <ORIGINALDATE>2005-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>How do I monitor the injection rate of activated carbon?</TITLE>
    <GRANULENUM>60.1330</GRANULENUM>
    <HEADING>Section 60.1330</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="5">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="4">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="3">AIR PROGRAMS (CONTINUED)</PARENT>
      <PARENT HEADING="PART 60" SEQ="2">STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES</PARENT>
      <PARENT HEADING="Subpart AAAA" SEQ="1">Standards of Performance for Small Municipal Waste Combustion Units for Which Construction is Commenced After August 30, 1999 or for Which Modification or Reconstruction is Commenced After June 6, 2001</PARENT>
      <PARENT HEADING="" SEQ="0">Other Monitoring Requirements</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 60.1330</SECTNO>
    <SUBJECT>How do I monitor the injection rate of activated carbon?</SUBJECT>
    <P>If your municipal waste combustion unit uses activated carbon to control dioxins/furans or mercury emissions, you must meet three requirements:</P>
    <P>(a) Select a carbon injection system operating parameter that can be used to calculate carbon feed rate (for example, screw feeder speed).</P>

    <P>(b) During each dioxins/furans and mercury stack test, determine the average carbon feed rate in kilograms (or pounds) per hour. Also, determine the average operating parameter level that <PRTPAGE P="655"/>correlates to the carbon feed rate. Establish a relationship between the operating parameter and the carbon feed rate in order to calculate the carbon feed rate based on the operating parameter level.</P>
    <P>(c) Continuously monitor the selected operating parameter during all periods when the municipal waste combustion unit is operating and combusting waste, and calculate the 8-hour block average carbon feed rate in kilograms (or pounds) per hour, based on the selected operating parameter. When calculating the 8-hour block average, do two things:</P>
    <P>(1) Exclude hours when the municipal waste combustion unit is not operating.</P>
    <P>(2) Include hours when the municipal waste combustion unit is operating but the carbon feed system is not working correctly.</P>