    <TITLE>Standard for nitrogen oxides.</TITLE>
    <GRANULENUM>60.44a</GRANULENUM>
    <HEADING>Section 60.44a</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="2">AIR PROGRAMS (CONTINUED)</PARENT>
      <PARENT HEADING="PART 60" SEQ="1">STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES</PARENT>
      <PARENT HEADING="Subpart Da" SEQ="0">Standards of Performance for Electric Utility Steam Generating Units for Which Construction is Commenced After September 18, 1978</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 60.44a</SECTNO>
    <SUBJECT>Standard for nitrogen oxides.</SUBJECT>

    <P>(a) On and after the date on which the initial performance test required to be conducted under § 60.8 is completed, no owner or operator subject to the provisions of this subpart shall cause to be discharged into the atmosphere from any affected facility, except as provided under paragraphs (b) and (d) of this section, any gases which contain nitrogen oxides (expressed as NO<E T="52">2</E>) in excess of the following emission limits, based on a 30-day rolling average, except as provided under § 60.46a(j)(1):</P>
    <P>(1) <E T="03">NO</E>
      <E T="54">x</E>
      <E T="03">emission limits.</E>
    </P>
    <GPOTABLE CDEF="s25,9,9" COLS="3" OPTS="L2">
      <BOXHD>
        <CHED H="1">Fuel type</CHED>
        <CHED H="1">Emission limit for heat input</CHED>
        <CHED H="2">ng/J</CHED>
        <CHED H="2">(lb/million Btu)</CHED>
      </BOXHD>
      <ROW>
        <ENT I="11">Gaseous fuels:</ENT>
      </ROW>
      <ROW>
        <ENT I="02">Coal-derived fuels</ENT>
        <ENT>210</ENT>
        <ENT>0.50</ENT>
      </ROW>
      <ROW>
        <ENT I="02">All other fuels</ENT>
        <ENT>86</ENT>
        <ENT>0.20</ENT>
      </ROW>
      <ROW>
        <ENT I="11">Liquid fuels:</ENT>
      </ROW>
      <ROW>
        <ENT I="02">Coal-derived fuels</ENT>
        <ENT>210</ENT>
        <ENT>0.50</ENT>
      </ROW>
      <ROW>
        <ENT I="02">Shale oil</ENT>
        <ENT>210</ENT>
        <ENT>0.50</ENT>
      </ROW>
      <ROW>
        <ENT I="02">All other fuels</ENT>
        <ENT>130</ENT>
        <ENT>0.30</ENT>
      </ROW>
      <ROW>
        <ENT I="11">Solid fuels:</ENT>
      </ROW>
      <ROW>
        <ENT I="02">Coal-derived fuels</ENT>
        <ENT>210</ENT>
        <ENT>0.50</ENT>
      </ROW>
      <ROW>
        <ENT I="02">Any fuel containing more than 25%, by weight, coal refuse</ENT>
        <ENT>(<SU>1</SU> )</ENT>
        <ENT>(<SU>1</SU> )</ENT>
      </ROW>
      <ROW>
        <ENT I="02">Any fuel containing more than 25%, by weight, lignite if the lignite is mined in North Dakota, South Dakota, or Montana, and is combusted in a slag tap furnace<SU>2</SU>
        </ENT>
        <ENT>340</ENT>
        <ENT>0.80</ENT>
      </ROW>
      <ROW>
        <ENT I="02">Any fuel containing more than 25%, by weight, lignite not subject to the 340 ng/J heat input emission limit<SU>2</SU>.</ENT>
      </ROW>
      <ROW>
        <ENT I="02">Subbituminous coal</ENT>
        <ENT>210</ENT>
        <ENT>0.50</ENT>
      </ROW>
      <ROW>
        <ENT I="02">Bituminous coal</ENT>
        <ENT>260</ENT>
        <ENT>0.60</ENT>
      </ROW>
      <ROW>
        <ENT I="02">Anthracite coal</ENT>
        <ENT>260</ENT>
        <ENT>0.60</ENT>
      </ROW>
      <ROW>
        <ENT I="02">All other fuels</ENT>
        <ENT>260</ENT>
        <ENT>0.60</ENT>
      </ROW>
      <TNOTE>
        <SU>1</SU> Exempt from NO<E T="52">X</E> standards and NO<E T="52">X</E> monitoring requirements.</TNOTE>
      <TNOTE>
        <SU>2</SU> Any fuel containing less than 25%, by weight, lignite is not prorated but its percentage is added to the percentage of the predominant fuel.</TNOTE>
    </GPOTABLE>
    <P>(2) <E T="03">NO</E>
      <E T="54">x</E>
      <E T="03">reduction requirement.</E>
      <PRTPAGE P="122"/>
    </P>
    <GPOTABLE CDEF="s25,12" COLS="2" OPTS="L2">
      <BOXHD>
        <CHED H="1">Fuel type</CHED>
        <CHED H="1">Percent reduction of potential combustion concentration</CHED>
      </BOXHD>
      <ROW>
        <ENT I="01">Gaseous fuels</ENT>
        <ENT O="oi0">25</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Liquid fuels</ENT>
        <ENT O="oi0">30</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Solid fuels</ENT>
        <ENT O="oi0">65</ENT>
      </ROW>
    </GPOTABLE>
    <P>(b) The emission limitations under paragraph (a) of this section do not apply to any affected facility which is combusting coal-derived liquid fuel and is operating under a commercial demonstration permit issued by the Administrator in accordance with the provisions of § 60.45a.</P>

    <P>(c) Except as provided under paragraph (d) of this section, when two or more fuels are combusted simultaneously, the applicable standard is determined by proration using the following formula:
    </P>
    <FP SOURCE="FP-1">E<E T="52">n</E>=[86 w+130×+210 y+260 z+340 v]/100</FP>
    
    <EXTRACT>
      <FP>where:</FP>
      
      <FP SOURCE="FP-1">E<E T="52">n</E>  is the applicable standard for nitrogen oxides when multiple fuels are combusted simultaneously (ng/J heat input);</FP>
      <FP SOURCE="FP-1">w is the percentage of total heat input derived from the combustion of fuels subject to the 86 ng/J heat input standard;</FP>
      <FP SOURCE="FP-1">x is the percentage of total heat input derived from the combustion of fuels subject to the 130 ng/J heat input standard;</FP>
      <FP SOURCE="FP-1">y is the percentage of total heat input derived from the combustion of fuels subject to the 210 ng/J heat input standard;</FP>
      <FP SOURCE="FP-1">z is the percentage of total heat input derived from the combustion of fuels subject to the 260 ng/J heat input standard; and</FP>
      <FP SOURCE="FP-1">v is the percentage of total heat input delivered from the combustion of fuels subject to the 340 ng/J heat input standard.</FP>
    </EXTRACT>
    

    <P>(d)(1) On and after the date on which the initial performance test required to be conducted under § 60.8 is completed, no new source owner or operator subject to the provisions of this subpart shall cause to be discharged into the atmosphere from any affected facility for which construction commenced after July 9, 1997 any gases which contain nitrogen oxides (expressed as NO<E T="52">2</E>) in excess of 200 nanograms per joule (1.6 pounds per megawatt-hour) gross energy output, based on a 30-day rolling average, except as provided under § 60.46a(k)(1).</P>

    <P>(2) On and after the date on which the initial performance test required to be conducted under § 60.8 is completed, no existing source owner or operator subject to the provisions of this subpart shall cause to be discharged into the atmosphere from any affected facility for which reconstruction commenced after July 9, 1997 any gases which contain nitrogen oxides (expressed as NO<E T="52">2</E>) in excess of 65 ng/Jl (0.15 pounds per million Btu) heat input, based on a 30-day rolling average.</P>
    <CITA>[44 FR 33613, June 11, 1979, as amended at 54 FR 6664, Feb. 14, 1989; 63 FR 49453, Sept. 16, 1998; 66 FR 18551, Apr. 10, 2001; 66 FR 42610, Aug. 14, 2001]</CITA>