<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>30</CFRTITLE>
    <CFRTITLETEXT>Mineral Resources</CFRTITLETEXT>
    <VOL>1</VOL>
    <DATE>2006-07-01</DATE>
    <ORIGINALDATE>2006-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Permanent splicing of trailing cables.</TITLE>
    <GRANULENUM>75.604</GRANULENUM>
    <HEADING>Section 75.604</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 30" SEQ="4">Mineral Resources</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR</PARENT>
      <PARENT HEADING="SUBCHAPTER O" SEQ="2">COAL MINE SAFETY AND HEALTH</PARENT>
      <PARENT HEADING="PART 75" SEQ="1">MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES</PARENT>
      <PARENT HEADING="Subpart G" SEQ="0">Trailing Cables</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 75.604</SECTNO>
    <SUBJECT>Permanent splicing of trailing cables.</SUBJECT>
    <HD SOURCE="HD1">[Statutory Provisions]</HD>
    <P>When permanent splices in trailing cables are made, they shall be:</P>
    <P>(a) Mechanically strong with adequate electrical conductivity and flexibility;</P>
    <P>(b) Effectively insulated and sealed so as to exclude moisture; and</P>
    <P>(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.</P>
    <P>(d) Made using splice kits accepted or approved by MSHA as flame resistant.</P>
    <CITA>[35 FR 17890, Nov. 20, 1970, as amended at 57 FR 61223, Dec. 23, 1992]</CITA>