<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>6</VOL>
    <DATE>2007-07-01</DATE>
    <ORIGINALDATE>2007-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Test methods and procedures.</TITLE>
    <GRANULENUM>60.176</GRANULENUM>
    <HEADING>Section 60.176</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="2">AIR PROGRAMS (CONTINUED)</PARENT>
      <PARENT HEADING="PART 60" SEQ="1">STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES</PARENT>
      <PARENT HEADING="Subpart Q" SEQ="0">Standards of Performance for Primary Zinc Smelters</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 60.176</SECTNO>
    <SUBJECT>Test methods and procedures.</SUBJECT>
    <P>(a) In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of this part or other methods and procedures as specified in this section, except as provided in § 60.8(b).</P>

    <P>(b) The owner or operator shall determine compliance with the particulate matter, sulfur dioxide (SO<E T="52">2</E>), and visible emission standards in §§ 60.172, 60.173, and 60.174 as follows:</P>
    <P>(1) Method 5 shall be used to determine the particulate matter concentration. The sampling time and sample volume for each run shall be at least 60 minutes and 0.85 dscm (30 dscf).</P>

    <P>(2) The continuous monitoring system of § 60.175(a)(2) shall be used to determine the SO<E T="52">2</E> concentrations on a dry basis. The sampling time for each run shall be 2 hours, and the average SO<E T="52">2</E> concentration for the 2-hour period shall be computed as in § 60.175(b). The monitoring system drift during the run may not exceed 2 percent of the span value.</P>
    <P>(3) Method 9 and the procedures in § 60.11 shall be used to determine opacity.</P>
    <CITA>[54 FR 6669, Feb. 14, 1989]</CITA>
  </SECTION>