<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>6</VOL>
    <DATE>2007-07-01</DATE>
    <ORIGINALDATE>2007-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Test methods and procedures.</TITLE>
    <GRANULENUM>60.224</GRANULENUM>
    <HEADING>Section 60.224</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="2">AIR PROGRAMS (CONTINUED)</PARENT>
      <PARENT HEADING="PART 60" SEQ="1">STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES</PARENT>
      <PARENT HEADING="Subpart V" SEQ="0">Standards of Performance for the Phosphate Fertilizer Industry: Diammonium Phosphate Plants</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 60.224</SECTNO>
    <SUBJECT>Test methods and procedures.</SUBJECT>
    <P>(a) In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of this part or other methods and procedures as specified in this section, except as provided in § 60.8(b).</P>
    <P>(b) The owner or operator shall determine compliance with the total fluorides standard in § 60.222 as follows:</P>
    <P>(1) The emission rate (E) of total fluorides shall be computed for each run using the following equation:</P>
    <GPH DEEP="32" SPAN="1">
      <GID>EC16NO91.009</GID>
    </GPH>
    <EXTRACT>
      <FP>where:</FP>
      

      <FP SOURCE="FP-1">E=emission rate of total fluorides, g/Mg (lb/ton) of equivalent P<E T="52">2</E>O<E T="52">5</E> feed.</FP>
      <FP SOURCE="FP-1">C<E T="52">si</E>=concentration of total fluorides from emission point “i,” mg/dscm (gr/dscf).</FP>
      <FP SOURCE="FP-1">Q<E T="52">sdi</E>=volumetric flow rate of effluent gas from emission point “i,” dscm/hr (dscf/hr).</FP>
      <FP SOURCE="FP-1">N=number of emission points associated with the affected facility.</FP>
      <FP SOURCE="FP-1">P=equivalent P<E T="52">2</E>O<E T="52">5</E> feed rate, Mg/hr (ton/hr).</FP>
      <FP SOURCE="FP-1">K=conversion factor, 1000 mg/g (7,000 gr/lb).</FP>
    </EXTRACT>
    

    <P>(2) Method 13A or 13B shall be used to determine the total fluorides concentration (C<E T="52">si</E>) and volumetric flow rate (Q<E T="52">sdi</E>) of the effluent gas from each of the emission points. The sampling time and sample volume for each run shall be at least 60 minutes and 0.85 dscm (30 dscf).</P>
    <P>(3) The equivalent P<E T="52">2</E>O<E T="52">5</E> feed rate (P) shall be computed for each run using the following equation:
    </P>
    <FP SOURCE="FP-1">P=M<E T="52">p</E> R<E T="52">p</E>
    </FP>
    
    <EXTRACT>
      <FP>where:</FP>
      
      <PRTPAGE P="339"/>
      <FP SOURCE="FP-1">M<E T="52">p</E>=total mass flow rate of phosphorus-bearing feed, Mg/hr (ton/hr).</FP>
      <FP SOURCE="FP-1">R<E T="52">p</E>=P<E T="52">2</E>O<E T="52">5</E> content, decimal fraction.</FP>
    </EXTRACT>
    

    <P>(i) The accountability system of § 60.223(a) shall be used to determine the mass flow rate (M<E T="52">p</E>) of the phosphorus-bearing feed.</P>

    <P>(ii) The Association of Official Analytical Chemists (AOAC) Method 9 (incorported by reference—see § 60.17) shall be used to determine the P<E T="52">2</E>O<E T="52">5</E> content (R<E T="52">p</E>) of the feed.</P>
    <CITA>[54 FR 6670, Feb. 14, 1989, as amended at 65 FR 61757, Oct. 17, 2000]</CITA>
  </SECTION>