<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>6</VOL>
    <DATE>2007-07-01</DATE>
    <ORIGINALDATE>2007-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Test methods and procedures.</TITLE>
    <GRANULENUM>60.424</GRANULENUM>
    <HEADING>Section 60.424</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="2">AIR PROGRAMS (CONTINUED)</PARENT>
      <PARENT HEADING="PART 60" SEQ="1">STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES</PARENT>
      <PARENT HEADING="Subpart PP" SEQ="0">Standards of Performance for Ammonium Sulfate Manufacture</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 60.424</SECTNO>
    <SUBJECT>Test methods and procedures.</SUBJECT>
    <P>(a) In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of this part or other methods and procedures as specified in this section, except as provided in § 60.8(b).</P>
    <P>(b) The owner or operator shall determine compliance with the particulate matter standards in § 60.422 as follows:</P>

    <P>(1) The emission rate (E) of particulate matter shall be computed for each run using the following equation:
    </P>
    <FP SOURCE="FP-1">E=(c<E T="52">s</E> Q<E T="52">sd</E>)/(PK)</FP>
    
    <EXTRACT>
      <FP>where:</FP>
      

      <FP SOURCE="FP-1">E=emission rate of particulate matter, kg/Mg (lb/ton) of ammonium sulfate produced.<PRTPAGE P="415"/>
      </FP>
      <FP SOURCE="FP-1">c<E T="52">s</E>=concentration of particulate matter, g/dscm (g/dscf).</FP>
      <FP SOURCE="FP-1">Q<E T="52">sd</E>=volumetric flow rate of effluent gas, dscm/hr (dscf/hr).</FP>
      <FP SOURCE="FP-1">P=production rate of ammonium sulfate, Mg/hr (ton/hr).</FP>
      <FP SOURCE="FP-1">K=conversion factor, 1000 g/kg (453.6 g/lb).</FP>
    </EXTRACT>
    

    <P>(2) Method 5 shall be used to determine the particulate matter concentration (c<E T="52">s</E>) and volumetric flow rate (Q<E T="52">sd</E>) of the effluent gas. The sampling time and sample volume for each run shall be at least 60 minutes and 1.50 dscm (53 dscf).</P>
    <P>(3) Direct measurement using product weigh scales, or the result of computations using a material balance, shall be used to determine the rate (P) of the ammonium sulfate production. If production rate is determined by material balance, the following equations shall be used:</P>

    <P>(i) For synthetic and coke oven by-product ammonium sulfate plants:
    </P>
    <FP SOURCE="FP-1">P=ABCK<FR>1/4</FR>
    </FP>
    
    <EXTRACT>
      <FP>where:</FP>
      
      <FP SOURCE="FP-1">A=sulfuric aid flow rate to the reactor/crystallizer averaged over the time-period taken to conduct the run, liter/min.</FP>
      <FP SOURCE="FP-1">B=acid density (a function of acid strength and temperature), g/cc.</FP>
      <FP SOURCE="FP-1">C=acid strength, decimal fraction.</FP>
      <FP SOURCE="FP-1">K<FR>1/4</FR>=conversion factor, 0.0808 (Mg-min-cc)/(g-hr-liter) [0.0891 (ton-min-cc)/(g-hr-liter)].</FP>
    </EXTRACT>
    
    <P>(ii) For caprolactam by-product ammonium sulfate plants:
    </P>
    <FP SOURCE="FP-1">P=DEFK″</FP>
    
    <EXTRACT>
      <FP>where:</FP>
      
      <FP SOURCE="FP-1">D=total combined feed stream flow rate to the ammonium crystallizer before the point where any recycle streams enter the stream averaged over the time-period taken to conduct the test run, liter/min.</FP>
      <FP SOURCE="FP-1">E=density of the process stream solution, -g/liter.</FP>
      <FP SOURCE="FP-1">F=percent mass of ammonium sulfate in the process solution, decimal fraction.</FP>
      <FP SOURCE="FP-1">K″=conversion factor, 6.0×10<E T="51">−5</E> (Mg-min)/(g-hr) [6.614×10<E T="51">−5</E> (ton-min)/(g-hr)].</FP>
    </EXTRACT>
    
    <P>(4) Method 9 and the procedures in § 60.11 shall be used to determine the opacity.</P>
    <CITA>[54 FR 6676, Feb. 14, 1989, as amended at 65 FR 61760, Oct. 17, 2000]</CITA>
  </SECTION>