    <TITLE>How do I perform the initial performance test if I have chosen to install a NOX-diluent CEMS?</TITLE>
    <GRANULENUM>60.4405</GRANULENUM>
    <HEADING>Section 60.4405</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="5">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="4">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="3">AIR PROGRAMS (CONTINUED)</PARENT>
      <PARENT HEADING="PART 60" SEQ="2">STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES</PARENT>
      <PARENT HEADING="Subpart KKKK" SEQ="1">Standards of Performance for Stationary Combustion Turbines</PARENT>
      <PARENT HEADING="" SEQ="0">Performance Tests</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 60.4405</SECTNO>

    <SUBJECT>How do I perform the initial performance test if I have chosen to install a NO<E T="0732">X</E>-diluent CEMS?</SUBJECT>
    <P>If you elect to install and certify a NO<E T="52">X</E>-diluent CEMS under § 60.4345, then the initial performance test required under § 60.8 may be performed in the following alternative manner:</P>
    <P>(a) Perform a minimum of nine RATA reference method runs, with a minimum time per run of 21 minutes, at a single load level, within plus or minus 25 percent of 100 percent of peak load. The ambient temperature must be greater than 0 °F during the RATA runs.</P>
    <P>(b) For each RATA run, concurrently measure the heat input to the unit using a fuel flow meter (or flow meters) and measure the electrical and thermal output from the unit.</P>

    <P>(c) Use the test data both to demonstrate compliance with the applicable NO<E T="52">X</E> emission limit under § 60.4320 and to provide the required reference method data for the RATA of the CEMS described under § 60.4335.</P>

    <P>(d) Compliance with the applicable emission limit in § 60.4320 is achieved if the arithmetic average of all of the NO<E T="52">X</E> emission rates for the RATA runs, expressed in units of ppm or lb/MWh, does not exceed the emission limit.</P>