<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>6</VOL>
    <DATE>2007-07-01</DATE>
    <ORIGINALDATE>2007-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>What definitions apply to this subpart?</TITLE>
    <GRANULENUM>60.4420</GRANULENUM>
    <HEADING>Section 60.4420</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="5">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="4">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="3">AIR PROGRAMS (CONTINUED)</PARENT>
      <PARENT HEADING="PART 60" SEQ="2">STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES</PARENT>
      <PARENT HEADING="Subpart KKKK" SEQ="1">Standards of Performance for Stationary Combustion Turbines</PARENT>
      <PARENT HEADING="" SEQ="0">Definitions</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 60.4420</SECTNO>
    <SUBJECT>What definitions apply to this subpart?</SUBJECT>
    <P>As used in this subpart, all terms not defined herein will have the meaning given them in the Clean Air Act and in subpart A (General Provisions) of this part.</P>
    <P>
      <E T="03">Combined cycle combustion turbine</E> means any stationary combustion turbine which recovers heat from the combustion turbine exhaust gases to generate steam that is only used to create additional power output in a steam turbine.</P>
    <P>
      <E T="03">Combined heat and power combustion turbine</E> means any stationary combustion turbine which recovers heat from the exhaust gases to heat water or another medium, generate steam for useful purposes other than additional electric generation, or directly uses the heat in the exhaust gases for a useful purpose.</P>
    <P>
      <E T="03">Combustion turbine model</E> means a group of combustion turbines having the same nominal air flow, combustor inlet pressure, combustor inlet temperature, firing temperature, turbine inlet temperature and turbine inlet pressure.</P>
    <P>
      <E T="03">Combustion turbine test cell/stand</E> means any apparatus used for testing uninstalled stationary or uninstalled mobile (motive) combustion turbines.</P>
    <P>
      <E T="03">Diffusion flame stationary combustion turbine</E> means any stationary combustion turbine where fuel and air are injected at the combustor and are mixed only by diffusion prior to ignition.</P>
    <P>
      <E T="03">Duct burner</E> means a device that combusts fuel and that is placed in the exhaust duct from another source, such as a stationary combustion turbine, internal combustion engine, kiln, etc., to allow the firing of additional fuel to heat the exhaust gases before the exhaust gases enter a heat recovery steam generating unit.</P>
    <P>
      <E T="03">Efficiency</E> means the combustion turbine manufacturer's rated heat rate at peak load in terms of heat input per unit of power output—based on the higher heating value of the fuel.</P>
    <P>
      <E T="03">Emergency combustion turbine</E> means any stationary combustion turbine which operates in an emergency situation. Examples include stationary combustion turbines used to produce power for critical networks or equipment, including power supplied to portions of a facility, when electric power from the local utility is interrupted, or stationary combustion turbines used to pump water in the case of fire or flood, etc. Emergency stationary combustion turbines do not include stationary combustion turbines used as peaking units at electric utilities or stationary combustion turbines at industrial facilities that typically operate at low capacity factors. Emergency combustion turbines may be operated for the purpose of maintenance checks and readiness testing, provided that the tests are required by the manufacturer, the vendor, or the insurance company associated with the turbine. Required testing of such units should be minimized, but there is no time limit on the use of emergency combustion turbines.</P>
    <P>
      <E T="03">Excess emissions</E> means a specified averaging period over which either (1) the NO<E T="52">X</E> emissions are higher than the applicable emission limit in § 60.4320; (2) the total sulfur content of the fuel being combusted in the affected facility exceeds the limit specified in § 60.4330; or (3) the recorded value of a particular monitored parameter is outside the acceptable range specified in the parameter monitoring plan for the affected unit.</P>
    <P>
      <E T="03">Gross useful output</E> means the gross useful work performed by the stationary combustion turbine system. For units using the mechanical energy directly or generating only electricity, the gross useful work performed is the gross electrical or mechanical output from the turbine/generator set. For combined heat and power units, the gross useful work performed is the gross electrical or mechanical output plus the useful thermal output (i.e., thermal energy delivered to a process).</P>
    <P>
      <E T="03">Heat recovery steam generating unit</E> means a unit where the hot exhaust gases from the combustion turbine are routed in order to extract heat from the gases and generate steam, for use in a steam turbine or other device that utilizes steam. Heat recovery steam generating units can be used with or without duct burners.</P>
    <P>
      <E T="03">Integrated gasification combined cycle electric utility steam generating unit</E>
      <PRTPAGE P="897"/>means a coal-fired electric utility steam generating unit that burns a synthetic gas derived from coal in a combined-cycle gas turbine. No solid coal is directly burned in the unit during operation.</P>
    <P>
      <E T="03">ISO conditions</E> means 288 Kelvin, 60 percent relative humidity and 101.3 kilopascals pressure.</P>
    <P>
      <E T="03">Lean premix stationary combustion turbine</E> means any stationary combustion turbine where the air and fuel are thoroughly mixed to form a lean mixture before delivery to the combustor. Mixing may occur before or in the combustion chamber. A lean premixed turbine may operate in diffusion flame mode during operating conditions such as startup and shutdown, extreme ambient temperature, or low or transient load.</P>
    <P>
      <E T="03">Natural gas</E> means a naturally occurring fluid mixture of hydrocarbons (e.g., methane, ethane, or propane) produced in geological formations beneath the Earth's surface that maintains a gaseous state at standard atmospheric temperature and pressure under ordinary conditions. Additionally, natural gas must either be composed of at least 70 percent methane by volume or have a gross calorific value between 950 and 1,100 British thermal units (Btu) per standard cubic foot. Natural gas does not include the following gaseous fuels: landfill gas, digester gas, refinery gas, sour gas, blast furnace gas, coal-derived gas, producer gas, coke oven gas, or any gaseous fuel produced in a process which might result in highly variable sulfur content or heating value.</P>
    <P>
      <E T="03">Noncontinental area</E> means the State of Hawaii, the Virgin Islands, Guam, American Samoa, the Commonwealth of Puerto Rico, the Northern Mariana Islands, or offshore platforms.</P>
    <P>
      <E T="03">Peak load</E> means 100 percent of the manufacturer's design capacity of the combustion turbine at ISO conditions.</P>
    <P>
      <E T="03">Regenerative cycle combustion turbine</E> means any stationary combustion turbine which recovers heat from the combustion turbine exhaust gases to preheat the inlet combustion air to the combustion turbine.</P>
    <P>
      <E T="03">Simple cycle combustion turbine</E> means any stationary combustion turbine which does not recover heat from the combustion turbine exhaust gases to preheat the inlet combustion air to the combustion turbine, or which does not recover heat from the combustion turbine exhaust gases for purposes other than enhancing the performance of the combustion turbine itself.</P>
    <P>
      <E T="03">Stationary combustion turbine</E> means all equipment, including but not limited to the turbine, the fuel, air, lubrication and exhaust gas systems, control systems (except emissions control equipment), heat recovery system, and any ancillary components and sub-components comprising any simple cycle stationary combustion turbine, any regenerative/recuperative cycle stationary combustion turbine, any combined cycle combustion turbine, and any combined heat and power combustion turbine based system. Stationary means that the combustion turbine is not self propelled or intended to be propelled while performing its function. It may, however, be mounted on a vehicle for portability.</P>
    <P>
      <E T="03">Unit operating day</E> means a 24-hour period between 12 midnight and the following midnight during which any fuel is combusted at any time in the unit. It is not necessary for fuel to be combusted continuously for the entire 24-hour period.</P>
    <P>
      <E T="03">Unit operating hour</E> means a clock hour during which any fuel is combusted in the affected unit. If the unit combusts fuel for the entire clock hour, it is considered to be a full unit operating hour. If the unit combusts fuel for only part of the clock hour, it is considered to be a partial unit operating hour.</P>
    <P>
      <E T="03">Useful thermal output</E> means the thermal energy made available for use in any industrial or commercial process, or used in any heating or cooling application, i.e., total thermal energy made available for processes and applications other than electrical or mechanical generation. Thermal output for this subpart means the energy in recovered thermal output measured against the energy in the thermal output at 15 degrees Celsius and 101.325 kilopascals of pressure.<PRTPAGE P="898"/>
    </P>
    <GPOTABLE CDEF="s75,r75,r75" COLS="3" OPTS="L2">
      <TTITLE>Table 1—to Subpart KKKK of Part 60—Nitrogen Oxide Emission Limits for New Stationary Combustion Turbines</TTITLE>
      <BOXHD>
        <CHED H="1">Combustion turbine type</CHED>
        <CHED H="1">Combustion turbine heat input at peak load<LI>(HHV)</LI>
        </CHED>
        <CHED H="1">NO<E T="52">X</E> emission standard</CHED>
      </BOXHD>
      <ROW>
        <ENT I="01">New turbine firing natural gas, electric generating</ENT>
        <ENT>≤ 50 MMBtu/h</ENT>
        <ENT>42 ppm at 15 percent O<E T="52">2</E> or 290 ng/J of useful output (2.3 lb/MWh).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">New turbine firing natural gas, mechanical drive</ENT>
        <ENT>≤ 50 MMBtu/h</ENT>
        <ENT>100 ppm at 15 percent O<E T="52">2</E> or 690 ng/J of useful output (5.5 lb/MWh).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">New turbine firing natural gas</ENT>
        <ENT>&gt; 50 MMBtu/h and ≤ 850 MMBtu/h</ENT>
        <ENT>25 ppm at 15 percent O<E T="52">2</E> or 150 ng/J of useful output (1.2 lb/MWh).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">New, modified, or reconstructed turbine firing natural gas</ENT>
        <ENT>&gt; 850 MMBtu/h</ENT>
        <ENT>15 ppm at 15 percent O<E T="52">2</E> or 54 ng/J of useful output (0.43 lb/MWh)</ENT>
      </ROW>
      <ROW>
        <ENT I="01">New turbine firing fuels other than natural gas, electric generating</ENT>
        <ENT>≤ 50 MMBtu/h</ENT>
        <ENT>96 ppm at 15 percent O<E T="52">2</E> or 700 ng/J of useful output (5.5 lb/MWh).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">New turbine firing fuels other than natural gas, mechanical drive</ENT>
        <ENT>≤ 50 MMBtu/h</ENT>
        <ENT>150 ppm at 15 percent O<E T="52">2</E> or 1,100 ng/J of useful output (8.7 lb/MWh).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">New turbine firing fuels other than natural gas</ENT>
        <ENT>&gt; 50 MMBtu/h and ≤ 850 MMBtu/h</ENT>
        <ENT>74 ppm at 15 percent O<E T="52">2</E> or 460 ng/J of useful output (3.6 lb/MWh).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">New, modified, or reconstructed turbine firing fuels other than natural gas</ENT>
        <ENT>&gt; 850 MMBtu/h</ENT>
        <ENT>42 ppm at 15 percent O<E T="52">2</E> or 160 ng/J of useful output (1.3 lb/MWh).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Modified or reconstructed turbine</ENT>
        <ENT>≤ 50 MMBtu/h</ENT>
        <ENT>150 ppm at 15 percent O<E T="52">2</E> or 1,100 ng/J of useful output (8.7 lb/MWh).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Modified or reconstructed turbine firing natural gas</ENT>
        <ENT>&gt; 50 MMBtu/h and ≤ 850 MMBtu/h</ENT>
        <ENT>42 ppm at 15 percent O<E T="52">2</E> or 250 ng/J of useful output (2.0 lb/MWh).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Modified or reconstructed turbine firing fuels other than natural gas</ENT>
        <ENT>&gt; 50 MMBtu/h and ≤ 850 MMBtu/h</ENT>
        <ENT>96 ppm at 15 percent O<E T="52">2</E> or 590 ng/J of useful output (4.7 lb/MWh).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Turbines located north of the Arctic Circle (latitude 66.5 degrees north), turbines operating at less than 75 percent of peak load, modified and reconstructed offshore turbines, and turbine operating at temperatures less than 0 °F</ENT>
        <ENT>≤ 30 MW output</ENT>
        <ENT>150 ppm at 15 percent O<E T="52">2</E> or 1,100 ng/J of useful output (8.7 lb/MWh).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Turbines located north of the Arctic Circle (latitude 66.5 degrees north), turbines operating at less than 75 percent of peak load, modified and reconstructed offshore turbines, and turbine operating at temperatures less than 0 °F</ENT>
        <ENT>&gt; 30 MW output</ENT>
        <ENT>96 ppm at 15 percent O<E T="52">2</E> or 590 ng/J of useful output (4.7 lb/MWh).</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Heat recovery units operating independent of the combustion turbine</ENT>
        <ENT>All sizes</ENT>
        <ENT>54 ppm at 15 percent O<E T="52">2</E> or 110 ng/J of useful output (0.86 lb/MWh).</ENT>
      </ROW>
    </GPOTABLE>
  </SECTION>
</CFRGRANULE>