<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>6</VOL>
    <DATE>2007-07-01</DATE>
    <ORIGINALDATE>2007-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Commercial demonstration permit.</TITLE>
    <GRANULENUM>60.47Da</GRANULENUM>
    <HEADING>Section 60.47Da</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="2">AIR PROGRAMS (CONTINUED)</PARENT>
      <PARENT HEADING="PART 60" SEQ="1">STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES</PARENT>
      <PARENT HEADING="Subpart Da" SEQ="0">Standards of Performance for Electric Utility Steam Generating Units for Which Construction is Commenced After September 18, 1978</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 60.47Da</SECTNO>
    <SUBJECT>Commercial demonstration permit.</SUBJECT>

    <P>(a) An owner or operator of an affected facility proposing to demonstrate an emerging technology may apply to the Administrator for a commercial demonstration permit. The Administrator will issue a commercial <PRTPAGE P="138"/>demonstration permit in accordance with paragraph (e) of this section. Commercial demonstration permits may be issued only by the Administrator, and this authority will not be delegated.</P>

    <P>(b) An owner or operator of an affected facility that combusts solid solvent refined coal (SRC-I) and who is issued a commercial demonstration permit by the Administrator is not subject to the SO<E T="52">2</E> emission reduction requirements under § 60.43Da(c) but must, as a minimum, reduce SO<E T="52">2</E> emissions to 20 percent of the potential combustion concentration (80 percent reduction) for each 24-hour period of steam generator operation and to less than 520 ng/J (1.20 lb/MMBtu) heat input on a 30-day rolling average basis.</P>

    <P>(c) An owner or operator of a fluidized bed combustion electric utility steam generator (atmospheric or pressurized) who is issued a commercial demonstration permit by the Administrator is not subject to the SO<E T="52">2</E> emission reduction requirements under § 60.43Da(a) but must, as a minimum, reduce SO<E T="52">2</E> emissions to 15 percent of the potential combustion concentration (85 percent reduction) on a 30-day rolling average basis and to less than 520 ng/J (1.20 lb/MMBtu) heat input on a 30-day rolling average basis.</P>

    <P>(d) The owner or operator of an affected facility that combusts coal-derived liquid fuel and who is issued a commercial demonstration permit by the Administrator is not subject to the applicable NO<E T="52">X</E> emission limitation and percent reduction under § 60.44Da(a) but must, as a minimum, reduce emissions to less than 300 ng/J (0.70 lb/MMBtu) heat input on a 30-day rolling average basis.</P>
    <P>(e) Commercial demonstration permits may not exceed the following equivalent MW electrical generation capacity for any one technology category, and the total equivalent MW electrical generation capacity for all commercial demonstration plants may not exceed 15,000 MW.</P>
    <GPOTABLE CDEF="s100,10,14" COLS="3" OPTS="L2">
      <BOXHD>
        <CHED H="1">Technology</CHED>
        <CHED H="1">Pollutant</CHED>
        <CHED H="1">Equivalent electrical capacity<LI>(MW electrical output)</LI>
        </CHED>
      </BOXHD>
      <ROW>
        <ENT I="01">Solid solvent refined coal (SCR I)</ENT>
        <ENT>SO<E T="0732">2</E>
        </ENT>
        <ENT>6,000-10,000</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Fluidized bed combustion (atmospheric)</ENT>
        <ENT>SO<E T="0732">2</E>
        </ENT>
        <ENT>400-3,000</ENT>
      </ROW>
      <ROW>
        <ENT I="01">Fluidized bed combustion (pressurized)</ENT>
        <ENT>SO<E T="0732">2</E>
        </ENT>
        <ENT>400-1,200</ENT>
      </ROW>
      <ROW RUL="n,s">
        <ENT I="01">Coal liquification</ENT>
        <ENT>NO<E T="0732">X</E>
        </ENT>
        <ENT>750-10,000</ENT>
      </ROW>
      <ROW>
        <ENT I="03">Total allowable for all technologies</ENT>
        <ENT/>
        <ENT>15,000</ENT>
      </ROW>
    </GPOTABLE>
  </SECTION>