    <TITLE>Test methods and procedures.</TITLE>
    <GRANULENUM>60.74</GRANULENUM>
    <HEADING>Section 60.74</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="2">AIR PROGRAMS (CONTINUED)</PARENT>
      <PARENT HEADING="PART 60" SEQ="1">STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES</PARENT>
      <PARENT HEADING="Subpart G" SEQ="0">Standards of Performance for Nitric Acid Plants</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 60.74</SECTNO>
    <SUBJECT>Test methods and procedures.</SUBJECT>
    <P>(a) In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of this part or other methods and procedures as specified in this section, except as provided in § 60.8(b). Acceptable alternative methods and procedures are given in paragraph (c) of this section.</P>

    <P>(b) The owner or operator shall determine compliance with the NO<E T="52">X</E> standard in § 60.72 as follows:</P>
    <P>(1) The emission rate (E) of NO<E T="52">X</E> shall be computed for each run using the following equation:
    </P>
    <FP SOURCE="FP-1">E=(C<E T="52">s</E> Q<E T="52">sd</E>)/(P K)</FP>
    
    <EXTRACT>
      <FP>where:</FP>
      
      <FP SOURCE="FP-1">E=emission rate of NO<E T="52">X</E> as NO<E T="52">2</E>, kg/metric ton (lb/ton) of 100 percent nitric acid.</FP>
      <FP SOURCE="FP-1">C<E T="52">s</E>=concentration of NO<E T="52">X</E> as NO<E T="52">2</E>, g/dscm (lb/dscf).</FP>
      <FP SOURCE="FP-1">Q<E T="52">sd</E>=volumetric flow rate of effluent gas, dscm/hr (dscf/hr).</FP>
      <FP SOURCE="FP-1">P=acid production rate, metric ton/hr (ton/hr) or 100 percent nitric acid.</FP>
      <FP SOURCE="FP-1">K=conversion factor, 1000 g/kg (1.0 lb/lb).</FP>
    </EXTRACT>
    
    <P>(2) Method 7 shall be used to determine the NO<E T="52">X</E> concentration of each grab sample. Method 1 shall be used to select the sampling site, and the sampling point shall be the centroid of the stack or duct or at a point no closer to the walls than 1 m (3.28 ft). Four grab samples shall be taken at approximately 15-minute intervals. The arithmetic mean of the four sample concentrations shall constitute the run value (C<E T="52">s</E>).</P>

    <P>(3) Method 2 shall be used to determine the volumetric flow rate (Q<E T="52">sd</E>) of the effluent gas. The measurement site shall be the same as for the NO<E T="52">X</E> sample. A velocity traverse shall be made once per run within the hour that the NO<E T="52">X</E> samples are taken.</P>

    <P>(4) The methods of § 60.73(c) shall be used to determine the production rate (P) of 100 percent nitric acid for each <PRTPAGE P="282"/>run. Material balance over the production system shall be used to confirm the production rate.</P>
    <P>(c) The owner or operator may use the following as alternatives to the reference methods and procedures specified in this section:</P>
    <P>(1) For Method 7, Method 7A, 7B, 7C, or 7D may be used. If Method 7C or 7D is used, the sampling time shall be at least 1 hour.</P>
    <P>(d) The owner or operator shall use the procedure in § 60.73(b) to determine the conversion factor for converting the monitoring data to the units of the standard.</P>
    <CITA>[54 FR 6666, Feb. 14, 1989]</CITA>