<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>6</VOL>
    <DATE>2008-07-01</DATE>
    <ORIGINALDATE>2008-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Reporting.</TITLE>
    <GRANULENUM>60.155</GRANULENUM>
    <HEADING>Section 60.155</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="2">AIR PROGRAMS (CONTINUED)</PARENT>
      <PARENT HEADING="PART 60" SEQ="1">STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES</PARENT>
      <PARENT HEADING="Subpart O" SEQ="0">Standards of Performance for Sewage Treatment Plants</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 60.155</SECTNO>
    <SUBJECT>Reporting.</SUBJECT>

    <P>(a) The owner or operator of any multiple hearth, fluidized bed, or electric <PRTPAGE P="354"/>sludge incinerator subject to the provisions of this subpart shall submit to the Administrator semi-annually a report in writing which contains the following:</P>
    <P>(1) A record of average scrubber pressure drop measurements for each period of 15 minutes duration or more during which the pressure drop of the scrubber was less than, by a percentage specified below, the average scrubber pressure drop measured during the most recent performance test. The percent reduction in scrubber pressure drop for which a report is required shall be determined as follows:</P>
    <P>(i) For incinerators that achieved an average particulate matter emission rate of 0.38 kg/Mg (0.75 lb/ton) dry sludge input or less during the most recent performance test, a scrubber pressure drop reduction of more than 30 percent from the average scrubber pressure drop recorded during the most recent performance test shall be reported.</P>

    <P>(ii) For incinerators that achieved an average particulate matter emission rate of greater than 0.38 kg/Mg (0.75 lb/ton) dry sludge input during the most recent performance test, a percent reduction in pressure drop greater than that calculated according to the following equation shall be reported:
    </P>
    <FP SOURCE="FP-1">P=−111E+72.15</FP>
    
    <EXTRACT>
      <FP>where P=Percent reduction in pressure drop, and</FP>
      <FP SOURCE="FP-1">E=Average particulate matter emissions (kg/megagram)</FP>
    </EXTRACT>
    
    <P>(2) A record of average oxygen content in the incinerator exhaust gas for each period of 1-hour duration or more that the oxygen content of the incinerator exhaust gas exceeds the average oxygen content measured during the most recent performance test by more than 3 percent.</P>
    <P>(b) The owner or operator of any multiple hearth, fluidized bed, or electric sludge incinerator from which the average particulate matter emission rate measured during the performance test required under § 60.154(d) exceeds 0.38 g/kg of dry sludge input (0.75 lb/ton of dry sludge input) shall include in the report for each calendar day that a decrease in scrubber pressure drop or increase in oxygen content of exhaust gas is reported a record of the following:</P>
    <P>(1) Scrubber pressure drop averaged over each 1-hour incinerator operating period.</P>
    <P>(2) Oxygen content in the incinerator exhaust averaged over each 1-hour incinerator operating period.</P>
    <P>(3) Temperatures of every hearth in multiple hearth incinerators; of the bed and outlet of fluidized bed incinerators; and of the drying, combustion, and cooling zones of electric incinerators averaged over each 1-hour incinerator operating period.</P>
    <P>(4) Rate of sludge charged to the incinerator averaged over each 1-hour incinerator operating period.</P>
    <P>(5) Incinerator fuel use averaged over each 8-hour incinerator operating period.</P>
    <P>(6) Moisture and volatile solids content of the daily grab sample of sludge charged to the incinerator.</P>
    <P>(c) The owner or operator of any sludge incinerator other than a multiple hearth, fluidized bed, or electric incinerator or any sludge incinerator equipped with a control device other than a wet scrubber shall include in the semi-annual report a record of control device operation measurements, as specified in the plan approved under § 60.153(e).</P>
    <CITA>[53 FR 39417, Oct. 6, 1988]</CITA>
  </SECTION>
</CFRGRANULE>