    <TITLE>Test methods and procedures.</TITLE>
    <GRANULENUM>60.64</GRANULENUM>
    <HEADING>Section 60.64</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="4">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="2">AIR PROGRAMS (CONTINUED)</PARENT>
      <PARENT HEADING="PART 60" SEQ="1">STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES</PARENT>
      <PARENT HEADING="Subpart F" SEQ="0">Standards of Performance for Portland Cement Plants</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 60.64</SECTNO>
    <SUBJECT>Test methods and procedures.</SUBJECT>
    <P>(a) In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of this part or other methods and procedures as specified in this section, except as provided in § 60.8(b).</P>
    <P>(b) The owner or operator shall determine compliance with the particulate matter standard in § 60.62 as follows:</P>

    <P>(1) The emission rate (E) of particulate matter shall be computed for each run using the following equation:
    </P>
    <FP SOURCE="FP-1">E=(c<E T="52">s</E> Q<E T="52">sd</E>)/(P K)</FP>
    
    <EXTRACT>
      <FP>where:</FP>
      
      <FP SOURCE="FP-1">E=emission rate of particulate matter, kg/metric ton (lb/ton) of kiln feed.</FP>
      <FP SOURCE="FP-1">c<E T="52">s</E>=concentration of particulate matter, g/dscm (gr/dscf).</FP>
      <FP SOURCE="FP-1">Q<E T="52">sd</E>=volumetric flow rate of effluent gas, dscm/hr (dscf/hr).</FP>
      <FP SOURCE="FP-1">P=total kiln feed (dry basis) rate, metric ton/hr (ton/hr).</FP>
      <FP SOURCE="FP-1">K=conversion factor, 1000 g/kg (7000 gr/lb).</FP>
    </EXTRACT>
    

    <P>(2) Method 5 shall be used to determine the particulate matter concentration (c<E T="52">s</E>) and the volumetric flow rate (Q<E T="52">sd</E>) of the effluent gas.</P>
    <FP>The sampling time and sample volume for each run shall be at least 60 minutes and 0.85 dscm (30.0 dscf) for the kiln and at least 60 minutes and 1.15 dscm (40.6 dscf) for the clinker cooler.</FP>
    <P>(3) Suitable methods shall be used to determine the kiln feed rate (P), except fuels, for each run. Material balance over the production system shall be used to confirm the feed rate.</P>
    <P>(4) Method 9 and the procedures in § 60.11 shall be used to determine opacity.</P>
    <CITA>[54 FR 6666, Feb. 14, 1989, as amended at 65 FR 61753, Oct. 17, 2000]</CITA>