[Title 40 CFR 60.103]
[Code of Federal Regulations (annual edition) - July 1, 2009 Edition]
[Title 40 - PROTECTION OF ENVIRONMENT]
[Chapter I - ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)]
[Subchapter C - AIR PROGRAMS (CONTINUED)]
[Part 60 - STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES--]
[Subpart J - Standards of Performance for Petroleum Refineries]
[Sec. 60.103 - Standard for carbon monoxide.]
[From the U.S. Government Printing Office]


40PROTECTION OF ENVIRONMENT62009-07-012009-07-01falseStandard for carbon monoxide.60.103Sec. 60.103PROTECTION OF ENVIRONMENTENVIRONMENTAL PROTECTION AGENCY (CONTINUED)AIR PROGRAMS (CONTINUED)STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES--Standards of Performance for Petroleum Refineries
Sec. 60.103  Standard for carbon monoxide.

    Each owner or operator of any fluid catalytic cracking unit catalyst 
regenerator that is subject to the requirements of this subpart shall 
comply with the emission limitations set forth in this section on and 
after the date on which the initial performance test, required by Sec. 
60.8, is completed, but not later than 60 days after achieving the 
maximum production rate at which the fluid catalytic cracking unit 
catalyst regenerator will be operated, or 180 days after initial 
startup, whichever comes first.
    (a) No owner or operator subject to the provisions of this subpart 
shall discharge or cause the discharge into the atmosphere from any 
fluid catalytic cracking unit catalyst regenerator any gases that 
contain carbon monoxide (CO) in excess of 500 ppm by volume (dry basis).

[54 FR 34027, Aug. 17, 1989, as amended at 55 FR 40175, Oct. 2, 1990]