40PROTECTION OF ENVIRONMENT62009-07-012009-07-01falseStandards for particulate matter.60.142aSec. 60.142aPROTECTION OF ENVIRONMENTENVIRONMENTAL PROTECTION AGENCY (CONTINUED)AIR PROGRAMS (CONTINUED)STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES--Standards of Performance for Secondary Emissions from Basic
Sec. 60.142a Standards for particulate matter.
(a) Except as provided under paragraphs (b) and (c) of this section,
on and after the date on which the performance test under Sec. 60.8 is
required to be completed, no owner or operator subject to the provisions
of this subpart shall cause to be discharged into the atmosphere from
any affected facility any secondary emissions that:
(1) Exit from the BOPF shop roof monitor (or other building
openings) and exhibit greater than 10 percent opacity during the steel
production cycle of any top-blown BOPF or during hot metal transfer or
skimming operations for any bottom-blown BOPF; except that an opacity
greater than 10 percent but less than 20 percent may occur once per
steel production cycle.
(2) Exit from a control device used solely for the collection of
secondary emissions from a top-blown BOPF or from hot metal transfer or
skimming for a top-blown or a bottom-blown BOPF and contain particulate
matter in excess of 23 mg/dscm (0.010 gr/dscf).
(3) Exit from a control device used solely for the collection of
secondary emissions from a top-blown BOPF or from hot metal transfer or
skimming for a top-blown or a bottom-blown BOPF and exhibit more than 5
percent opacity.
(b) A fume suppression system used to control secondary emissions
from an affected facility is not subject to paragraphs (a)(2) and (a)(3)
of this section.
(c) A control device used to collect both primary and secondary
emissions from a BOPF is not subject to paragraphs (a)(2) and (a)(3) of
this section.