40PROTECTION OF ENVIRONMENT62009-07-012009-07-01falseMonitoring of operations.60.143aSec. 60.143aPROTECTION OF ENVIRONMENTENVIRONMENTAL PROTECTION AGENCY (CONTINUED)AIR PROGRAMS (CONTINUED)STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES--Standards of Performance for Secondary Emissions from Basic
Sec. 60.143a Monitoring of operations.
(a) Each owner or operator of an affected facility shall install,
calibrate, operate, and maintain a monitoring device that continually
measures and records for each steel production cycle the various rates
or levels of exhaust ventilation at each phase of the cycle through each
duct of the secondary emission capture system. The monitoring device or
devices are to be placed at locations near each capture point of the
secondary emission capture system to monitor the exhaust ventilation
rates or levels adequately, or in alternative locations approved in
advance by the Administrator.
(b) If a chart recorder is used, the owner or operator shall use
chart recorders that are operated at a minimum chart speed of 3.8 cm/hr
(1.5 in./hr).
(c) All monitoring devices required by paragraph (a) of this section
are to be certified by the manufacturer to be accurate to within 10 percent compared to Method 2 of appendix A of this
part. The owner or operator shall recalibrate and check the device(s)
annually and at other times as the Administrator may require, in
accordance with the written instructions of the manufacturer and by
comparing the device against Method 2.
(d) Each owner or operator subject to the requirements of paragraph
(a) of this section shall report on a semiannual basis all measurements
of exhaust ventilation rates or levels over any 3-hour period that
average more than 10 percent below the average rates or levels of
exhaust ventilation maintained during the most recent performance test
conducted under Sec. 60.8 in which the affected facility demonstrated
compliance with the standard under Sec. 60.142a(a)(2). The accuracy of
the respective measurements, not to exceed the values specified in
paragraph (c) of this section, may be considered when determining the
measurement results that must be reported.
(e) If a scrubber primary emission control device is used to collect
secondary emissions, the owner or operator shall report on a semiannual
basis all measurements of exhaust ventilation rate over any 3-hour
period that average more than 10 percent below the average levels
maintained during the
[[Page 376]]
most recent performance test conducted under Sec. 60.8 in which the
affected facility demonstrated compliance with the standard under Sec.
60.142(a)(1).
[51 FR 161, Jan. 2, 1986, as amended at 65 FR 61756, Oct. 17, 2000]