Sec. 60.166 Test methods and procedures.
(a) In conducting performance tests required in Sec. 60.8, the
owner or operator shall use as reference methods and procedures the test
methods in appendix A of this part or other methods and procedures as
specified in this section, except as provided in Sec. 60.8(b).
(b) The owner or operator shall determine compliance with the
particulate matter, sulfur dioxide (SO2) and visible emission
standards in Sec. Sec. 60.162, 60.163, and 60.164 as follows:
(1) Method 5 shall be used to determine the particulate matter
concentration. The sampling time and sample volume for each run shall be
at least 60 minutes and 0.85 dscm (30 dscf).
(2) The continuous monitoring system of Sec. 60.165(b)(2) shall be
used to determine the SO2 concentrations on a dry basis. The
sampling time for each run shall be 6 hours, and the average
SO2 concentration shall be computed for the 6-hour period as
in Sec. 60.165(c). The monitoring system drift during the run may not
exceed 2 percent of the span value.
(3) Method 9 and the procedures in Sec. 60.11 shall be used to
determine opacity.