Sec. 60.175 Monitoring of operations.
(a) The owner or operator of any primary zinc smelter subject to the
provisions of this subpart shall install and operate:
(1) A continuous monitoring system to monitor and record the opacity
of gases discharged into the atmosphere from any sintering machine. The
span of this system shall be set at 80 to 100 percent opacity.
(2) A continuous monitoring system to monitor and record sulfur
dioxide emissions discharged into the atmosphere from any roaster
subject to Sec. 60.173. The span of this system shall be set at a
sulfur dioxide concentration of 0.20 percent by volume.
(i) The continuous monitoring system performance evaluation required
under Sec. 60.13(c) shall be completed prior to the initial performance
test required under Sec. 60.8.
(ii) For the purpose of the continuous monitoring system performance
evaluation required under Sec. 60.13(c), the reference method referred
to under the Relative Accuracy Test Procedure in Performance
Specification 2 of appendix B to this part shall be Method 6. For the
performance evaluation, each concentration measurement shall be of 1
hour duration. The pollutant gas used to prepare the calibration gas
mixtures required under Performance Specification 2 of appendix B, and
for calibration checks under Sec. 60.13(d), shall be sulfur dioxide.
(b) Two-hour average sulfur dioxide concentrations shall be
calculated and recorded daily for the 12 consecutive 2-hour periods of
each operating day. Each 2-hour average shall be determined as the
arithmetic mean of the appropriate two contiguous 1-hour average sulfur
dioxide concentrations provided by the continuous monitoring system
installed under paragraph (a) of this section.
(c) For the purpose of reports required under Sec. 60.7(c), periods
of excess emissions that shall be reported are defined as follows:
(1) Opacity. Any 6-minute period during which the average opacity,
as measured by the continuous monitoring system installed under
paragraph (a) of this section, exceeds the standard under Sec.
60.174(a).
(2) Sulfur dioxide. Any 2-hour period, as described in paragraph (b)
of this section, during which the average emissions of sulfur dioxide,
as measured by the continuous monitoring system installed under
paragraph (a) of this section, exceeds the standard under Sec. 60.173.
[41 FR 2340, Jan. 15, 1976, as amended at 48 FR 23611, May 25, 1983; 54
FR 6668, Feb. 14, 1989]