Sec. 60.213 Monitoring of operations.
(a) The owner or operator of any superphosphoric acid plant subject
to the provisions of this subpart shall install, calibrate, maintain,
and operate a flow monitoring device which can be used to determine the
mass flow of phosphorus-bearing feed material to the process. The flow
monitoring device shall have an accuracy of 5
percent over its operating range.
(b) The owner or operator of any superphosphoric acid plant shall
maintain a daily record of equivalent P2O5 feed by
first determining the total mass rate in Mg/hr of phosphorus-bearing
feed using a flow monitoring device meeting the requirements of
paragraph (a) of this section and then by proceeding according to Sec.
60.214(b)(3).
(c) The owner or operator of any superphosphoric acid plant subject
to the provisions of this part shall install, calibrate, maintain, and
operate a monitoring device which continuously measures and permanently
records the total pressure drop across the process scrubbing system. The
monitoring device shall have an accuracy of 5
percent over its operating range.
[40 FR 33155, Aug. 6, 1975, as amended at 54 FR 6670, Feb. 14, 1989; 65
FR 61757, Oct. 17, 2000]