40PROTECTION OF ENVIRONMENT62009-07-012009-07-01falseTest methods and procedures.60.254Sec. 60.254PROTECTION OF ENVIRONMENTENVIRONMENTAL PROTECTION AGENCY (CONTINUED)AIR PROGRAMS (CONTINUED)STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES--Standards of Performance for Coal Preparation Plants
Sec. 60.254 Test methods and procedures.
(a) In conducting the performance tests required in Sec. 60.8, the
owner or operator shall use as reference methods and procedures the test
methods in appendix A of this part or other methods and procedures as
specified in this section, except as provided in Sec. 60.8(b).
(b) The owner or operator shall determine compliance with the
particular matter standards in Sec. 60.252 as follows:
(1) Method 5 shall be used to determine the particulate matter
concentration. The sampling time and sample volume for each run shall be
at least 60 minutes and 0.85 dscm (30 dscf). Sampling shall begin no
less than 30 minutes after startup and shall terminate before shutdown
procedures begin.
(2) Method 9 and the procedures in Sec. 60.11 shall be used to
determine opacity.
[54 FR 6671, Feb. 14, 1989]