40PROTECTION OF ENVIRONMENT62009-07-012009-07-01falseMonitoring of operations.60.265Sec. 60.265PROTECTION OF ENVIRONMENTENVIRONMENTAL PROTECTION AGENCY (CONTINUED)AIR PROGRAMS (CONTINUED)STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES--Standards of Performance for Ferroalloy Production Facilities
Sec. 60.265 Monitoring of operations.
(a) The owner or operator of any electric submerged arc furnace
subject to the provisions of this subpart shall maintain daily records
of the following information:
(1) Product being produced.
(2) Description of constituents of furnace charge, including the
quantity, by weight.
(3) Time and duration of each tapping period and the identification
of material tapped (slag or product.)
(4) All furnace power input data obtained under paragraph (b) of
this section.
(5) All flow rate data obtained under paragraph (c) of this section
or all fan motor power consumption and pressure drop data obtained under
paragraph (e) of this section.
(b) The owner or operator subject to the provisions of this subpart
shall install, calibrate, maintain, and operate a device to measure and
continuously record the furnace power input. The furnace power input may
be measured at the output or input side of the transformer. The device
must have an accuracy of 5 percent over its
operating range.
(c) The owner or operator subject to the provisions of this subpart
shall install, calibrate, and maintain a monitoring device that
continuously measures and records the volumetric flow rate through each
separately ducted hood of the capture system, except as provided under
paragraph (e) of this section. The owner or operator of an electric
submerged arc furnace that is equipped with a water cooled cover which
is designed to contain and prevent escape of the generated gas and
particulate matter shall monitor only the volumetric flow rate through
the capture system for control of emissions from the tapping station.
The owner or operator may install the monitoring device(s) in any
appropriate location in the exhaust duct such that reproducible flow
rate monitoring will result. The flow rate monitoring device must have
an accuracy of 10 percent over its normal
operating range and must be calibrated according to the manufacturer's
instructions. The Administrator may require the owner or operator to
demonstrate the accuracy of the monitoring device relative to Methods 1
and 2 of appendix A to this part.
[[Page 402]]
(d) When performance tests are conducted under the provisions of
Sec. 60.8 of this part to demonstrate compliance with the standards
under Sec. Sec. 60.262(a) (4) and (5), the volumetric flow rate through
each separately ducted hood of the capture system must be determined
using the monitoring device required under paragraph (c) of this
section. The volumetric flow rates must be determined for furnace power
input levels at 50 and 100 percent of the nominal rated capacity of the
electric submerged arc furnace. At all times the electric submerged arc
furnace is operated, the owner or operator shall maintain the volumetric
flow rate at or above the appropriate levels for that furnace power
input level determined during the most recent performance test. If
emissions due to tapping are captured and ducted separately from
emissions of the electric submerged arc furnace, during each tapping
period the owner or operator shall maintain the exhaust flow rates
through the capture system over the tapping station at or above the
levels established during the most recent performance test. Operation at
lower flow rates may be considered by the Administrator to be
unacceptable operation and maintenance of the affected facility. The
owner or operator may request that these flow rates be reestablished by
conducting new performance tests under Sec. 60.8 of this part.
(e) The owner or operator may as an alternative to paragraph (c) of
this section determine the volumetric flow rate through each fan of the
capture system from the fan power consumption, pressure drop across the
fan and the fan performance curve. Only data specific to the operation
of the affected electric submerged arc furnace are acceptable for
demonstration of compliance with the requirements of this paragraph. The
owner or operator shall maintain on file a permanent record of the fan
performance curve (prepared for a specific temperature) and shall:
(1) Install, calibrate, maintain, and operate a device to
continuously measure and record the power consumption of the fan motor
(measured in kilowatts), and
(2) Install, calibrate, maintain, and operate a device to
continuously measure and record the pressure drop across the fan. The
fan power consumption and pressure drop measurements must be
synchronized to allow real time comparisions of the data. The monitoring
devices must have an accuracy of 5 percent over
their normal operating ranges.
(f) The volumetric flow rate through each fan of the capture system
must be determined from the fan power consumption, fan pressure drop,
and fan performance curve specified under paragraph (e) of this section,
during any performance test required under Sec. 60.8 to demonstrate
compliance with the standards under Sec. Sec. 60.262(a)(4) and (5). The
owner or operator shall determine the volumetric flow rate at a
representative temperature for furnace power input levels of 50 and 100
percent of the nominal rated capacity of the electric submerged arc
furnace. At all times the electric submerged arc furnace is operated,
the owner or operator shall maintain the fan power consumption and fan
pressure drop at levels such that the volumetric flow rate is at or
above the levels established during the most recent performance test for
that furnace power input level. If emissions due to tapping are captured
and ducted separately from emissions of the electric submerged arc
furnace, during each tapping period the owner or operator shall maintain
the fan power consumption and fan pressure drop at levels such that the
volumetric flow rate is at or above the levels established during the
most recent performance test. Operation at lower flow rates may be
considered by the Administrator to be unacceptable operation and
maintenance of the affected facility. The owner or operator may request
that these flow rates be reestablished by conducting new performance
tests under Sec. 60.8. The Administrator may require the owner or
operator to verify the fan performance curve by monitoring necessary fan
operating parameters and determining the gas volume moved relative to
Methods 1 and 2 of appendix A to this part.
(g) All monitoring devices required under paragraphs (c) and (e) of
this section are to be checked for calibration annually in accordance
with the procedures under Sec. 60.13(b).