Sec. 60.303 Test methods and procedures.
(a) In conducting the performance tests required in Sec. 60.8, the
owner or operator shall use as reference methods and procedures the test
methods in appendix A of this part or other methods and procedures as
specified in this section, except as provided in Sec. 60.8(b).
Acceptable alternative methods and procedures are given in paragraph (c)
of this section.
(b) The owner or operator shall determine compliance with the
particulate matter standards in Sec. 60.302 as follows:
(1) Method 5 shall be used to determine the particulate matter
concentration and the volumetric flow rate of the effluent gas. The
sampling time and sample volume for each run shall be at least 60
minutes and 1.70 dscm (60 dscf). The probe and filter holder shall be
operated without heaters.
(2) Method 2 shall be used to determine the ventilation volumetric
flow rate.
(3) Method 9 and the procedures in Sec. 60.11 shall be used to
determine opacity.
(c) The owner or operator may use the following as alternatives to
the reference methods and procedures specified in this section:
(1) For Method 5, Method 17 may be used.
[54 FR 6674, Feb. 14, 1989]