[Title 40 CFR 60.3039]
[Code of Federal Regulations (annual edition) - July 1, 2009 Edition]
[Title 40 - PROTECTION OF ENVIRONMENT]
[Chapter I - ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)]
[Subchapter C - AIR PROGRAMS (CONTINUED)]
[Part 60 - STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES--]
[Subpart Ffff - Emission Guidelines and Compliance Times for Other Solid]
[Sec. 60.3039 - How do I make sure my continuous emission monitoring systems]
[From the U.S. Government Printing Office]
40PROTECTION OF ENVIRONMENT62009-07-012009-07-01falseHow do I make sure my continuous emission monitoring systems60.3039Sec. 60.3039PROTECTION OF ENVIRONMENTENVIRONMENTAL PROTECTION AGENCY (CONTINUED)AIR PROGRAMS (CONTINUED)STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES--Emission Guidelines and Compliance Times for Other Solid
Sec. 60.3039 How do I make sure my continuous emission monitoring systems
are operating correctly?
(a) Conduct initial, daily, quarterly, and annual evaluations of
your continuous emission monitoring systems that measure carbon monoxide
and oxygen.
(b) Complete your initial evaluation of the continuous emission
monitoring systems within 180 days after your final compliance date in
table 1 of this subpart.
(c) For initial and annual evaluations, collect data concurrently
(or within 30 to 60 minutes) using your carbon monoxide and oxygen
continuous emission monitoring systems. To validate carbon monoxide
concentration levels, use EPA Method 10, 10A, or 10B of appendix A of
this part. Use EPA Method 3 or 3A to measure oxygen. Collect the data
during each initial and annual evaluation of your continuous emission
monitoring systems following the applicable performance specifications
in appendix B of this part. table 4 of this subpart shows the required
span values and performance specifications that apply to each continuous
emission monitoring system.
(d) Follow the quality assurance procedures in Procedure 1 of
appendix F of this part for each continuous emission monitoring system.
The procedures include daily calibration drift and quarterly accuracy
determinations.