[Title 40 CFR 60.4305]
[Code of Federal Regulations (annual edition) - July 1, 2009 Edition]
[Title 40 - PROTECTION OF ENVIRONMENT]
[Chapter I - ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)]
[Subchapter C - AIR PROGRAMS (CONTINUED)]
[Part 60 - STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES--]
[Subpart Kkkk - Standards of Performance for Stationary Combustion Turbines]
[Sec. 60.4305 - Does this subpart apply to my stationary combustion turbine?]
[From the U.S. Government Printing Office]


40PROTECTION OF ENVIRONMENT62009-07-012009-07-01falseDoes this subpart apply to my stationary combustion turbine?60.4305Sec. 60.4305PROTECTION OF ENVIRONMENTENVIRONMENTAL PROTECTION AGENCY (CONTINUED)AIR PROGRAMS (CONTINUED)STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES--Standards of Performance for Stationary Combustion Turbines
Sec. 60.4305  Does this subpart apply to my stationary combustion turbine?

    (a) If you are the owner or operator of a stationary combustion 
turbine with a heat input at peak load equal to or greater than 10.7 
gigajoules (10 MMBtu) per hour, based on the higher heating value of the 
fuel, which commenced construction, modification, or reconstruction 
after February 18, 2005, your turbine is subject to this subpart. Only 
heat input to the combustion turbine should be included when determining 
whether or not this subpart is applicable to your turbine. Any 
additional heat input to associated heat recovery steam generators 
(HRSG) or duct burners should not be included when determining your peak 
heat input. However, this subpart does apply to emissions from any 
associated HRSG and duct burners.
    (b) Stationary combustion turbines regulated under this subpart are 
exempt from the requirements of subpart GG of this part. Heat recovery 
steam generators and duct burners regulated under this subpart are 
exempted from the requirements of subparts Da, Db, and Dc of this part.