[Title 40 CFR 60.496]
[Code of Federal Regulations (annual edition) - July 1, 2009 Edition]
[Title 40 - PROTECTION OF ENVIRONMENT]
[Chapter I - ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)]
[Subchapter C - AIR PROGRAMS (CONTINUED)]
[Part 60 - STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES--]
[Subpart Ww - Standards of Performance for the Beverage Can Surface Coating]
[Sec. 60.496 - Test methods and procedures.]
[From the U.S. Government Printing Office]
40PROTECTION OF ENVIRONMENT62009-07-012009-07-01falseTest methods and procedures.60.496Sec. 60.496PROTECTION OF ENVIRONMENTENVIRONMENTAL PROTECTION AGENCY (CONTINUED)AIR PROGRAMS (CONTINUED)STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES--Standards of Performance for the Beverage Can Surface Coating
Sec. 60.496 Test methods and procedures.
(a) The reference methods in appendix A to this part, except as
provided in Sec. 60.8, shall be used to conduct performance tests.
(1) Method 24, an equivalent or alternative method approved by the
Administrator, or manufacturers' formulation data from which the VOC
content of the coatings used for each affected facility can be
calculated. In the event of a dispute, Method 24 data shall govern. When
VOC content of water-borne coatings, determined from data generated by
Method 24, is used to determine compliance of affected facilities, the
results of the Method 24 analysis shall be adjusted as described in
Section 12.6 of Method 24.
(2) Method 25 or an equivalent or alternative method for the
determination of the VOC concentration in the effluent gas entering and
leaving the control device for each stack equipped with an emission
control device. The owner or operator shall notify the Administrator at
least 30 days in advance of any State test using Method 25. The
[[Page 550]]
following reference methods are to be used in conjunction with Method
25:
(i) Method 1 for sample and velocity traverses,
(ii) Method 2 for velocity and volumetric flow rate,
(iii) Method 3 for gas analysis, and
(iv) Method 4 for stack gas moisture.
(b) For Method 24, the coating sample must be a 1-litre sample
collected in a 1-litre container at a point where the sample will be
representative of the coating material.
(c) For Method 25, the sampling time for each of three runs must be
at least 1 hour. The minimum sample volume must be 0.003 dscm except
that shorter sampling times or smaller volumes, when necessitated by
process variables or other factors, may be approved by the
Administrator. The Administrator will approve the sampling of
representative stacks on a case-by-case basis if the owner or operator
can demonstrate to the satisfaction of the Administrator that the
testing of representative stacks would yield results comparable to those
that would be obtained by testing all stacks.
[48 FR 38737, Aug. 25, 1983, as amended at 65 FR 61763, Oct. 17, 2000]