Sec. 60.63 Monitoring of operations.
(a) The owner or operator of any portland cement plant subject to
the provisions of this part shall record the daily production rates and
kiln feed rates.
(b) Except as provided in paragraph (c) of this section, each owner
or operator of a kiln or clinker cooler that is subject to the
provisions of this subpart shall install, calibrate, maintain, and
operate in accordance with Sec. 60.13 a continuous opacity monitoring
system to measure the opacity of emissions discharged into the
atmosphere from any kiln or clinker cooler. Except as provided in
paragraph (c) of this section, a continuous opacity monitoring system
shall be installed on each stack of any multiple stack device
controlling emissions from any kiln or clinker cooler. If there is a
separate bypass installed, each owner or operator of a kiln or clinker
cooler shall also install, calibrate, maintain, and operate a continuous
opacity monitoring system on each bypass stack in addition to the main
control device stack. Each owner or operator of an affected kiln or
clinker cooler for which the performance test required under Sec. 60.8
has been completed on or prior to December 14, 1988, shall install the
continuous opacity monitoring system within 180 days after December 14,
1988.
(c) Each owner or operator of a kiln or clinker cooler subject to
the provisions of this subpart using a positive-pressure fabric filter
with multiple stacks, or a negative-pressure fabric filter with multiple
stacks, or an electrostatic precipitator with multiple stacks may, in
lieu of installing the continuous opacity monitoring system required by
Sec. 60.63(b), monitor visible emissions at least once per day by using
a certified visible emissions observer. If the control device exhausts
gases through a monovent, visible emission observations in lieu of a
continuous opacity monitoring system are required. These observations
shall be taken in accordance with EPA Method
[[Page 310]]
9. Visible emissions shall be observed during conditions representative
of normal operation. Observations shall be recorded for at least three
6-minute periods each day. In the event that visible emissions are
observed for a number of emission sites from the control device with
multiple stacks, Method 9 observations shall be recorded for the
emission site with the highest opacity. All records of visible emissions
shall be maintained for a period of 2 years.
(d) For the purpose of reports under Sec. 60.65, periods of excess
emissions that shall be reported are defined as all 6-minute periods
during which the average opacity exceeds that allowed by Sec.
60.62(a)(2) or Sec. 60.62(b)(2).
(e) The provisions of paragraphs (a), (b), and (c) of this section
apply to kilns and clinker coolers for which construction, modification,
or reconstruction commenced after August 17, 1971.
[36 FR 24877, Dec. 23, 1971, as amended at 53 FR 50363, Dec. 14, 1988]