[Title 40 CFR 60.72]
[Code of Federal Regulations (annual edition) - July 1, 2009 Edition]
[Title 40 - PROTECTION OF ENVIRONMENT]
[Chapter I - ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)]
[Subchapter C - AIR PROGRAMS (CONTINUED)]
[Part 60 - STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES--]
[Subpart G - Standards of Performance for Nitric Acid Plants]
[Sec. 60.72 - Standard for nitrogen oxides.]
[From the U.S. Government Printing Office]


40PROTECTION OF ENVIRONMENT62009-07-012009-07-01falseStandard for nitrogen oxides.60.72Sec. 60.72PROTECTION OF ENVIRONMENTENVIRONMENTAL PROTECTION AGENCY (CONTINUED)AIR PROGRAMS (CONTINUED)STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES--Standards of Performance for Nitric Acid Plants
Sec. 60.72  Standard for nitrogen oxides.

    (a) On and after the date on which the performance test required to 
be conducted by Sec. 60.8 is completed, no owner or operator subject to 
the provisions of this subpart shall cause to be discharged into the 
atmosphere from any affected facility any gases which:
    (1) Contain nitrogen oxides, expressed as NO2, in excess 
of 1.5 kg per metric ton of acid produced (3.0 lb per ton), the 
production being expressed as 100 percent nitric acid.
    (2) Exhibit 10 percent opacity, or greater.

[39 FR 20794, June 14, 1974, as amended at 40 FR 46258, Oct. 6, 1975]