Sec. 60.74 Test methods and procedures.
(a) In conducting the performance tests required in Sec. 60.8, the
owner or operator shall use as reference methods and procedures the test
methods in appendix A of this part or other methods and procedures as
specified in this section, except as provided in Sec. 60.8(b).
Acceptable alternative methods and procedures are given in paragraph (c)
of this section.
(b) The owner or operator shall determine compliance with the
NOX standard in Sec. 60.72 as follows:
(1) The emission rate (E) of NOX shall be computed for
each run using the following equation:
E=(Cs Qsd)/(P K)
where:
E=emission rate of NOX as NO2, kg/metric ton (lb/
ton) of 100 percent nitric acid.
Cs=concentration of NOX as NO2, g/dscm
(lb/dscf).
Qsd=volumetric flow rate of effluent gas, dscm/hr (dscf/hr).
P=acid production rate, metric ton/hr (ton/hr) or 100 percent nitric
acid.
K=conversion factor, 1000 g/kg (1.0 lb/lb).
(2) Method 7 shall be used to determine the NOX
concentration of each grab sample. Method 1 shall be used to select the
sampling site, and the sampling point shall be the centroid of the stack
or duct or at a point no closer to the walls than 1 m (3.28 ft). Four
grab samples shall be taken at approximately 15-minute intervals. The
arithmetic mean of the four sample concentrations shall constitute the
run value (Cs).
(3) Method 2 shall be used to determine the volumetric flow rate
(Qsd) of the effluent gas. The measurement site shall be the
same as for the NOX sample. A velocity traverse shall be made
once per run within the hour that the NOX samples are taken.
(4) The methods of Sec. 60.73(c) shall be used to determine the
production rate (P) of 100 percent nitric acid for each run. Material
balance over the production system shall be used to confirm the
production rate.
(c) The owner or operator may use the following as alternatives to
the reference methods and procedures specified in this section:
(1) For Method 7, Method 7A, 7B, 7C, or 7D may be used. If Method 7C
or 7D is used, the sampling time shall be at least 1 hour.
(d) The owner or operator shall use the procedure in Sec. 60.73(b)
to determine the conversion factor for converting the monitoring data to
the units of the standard.
[54 FR 6666, Feb. 14, 1989]