<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>40</CFRTITLE>
    <CFRTITLETEXT>Protection of Environment</CFRTITLETEXT>
    <VOL>2</VOL>
    <DATE>2010-07-01</DATE>
    <ORIGINALDATE>2010-07-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>National primary and secondary ambient air quality standards for lead.</TITLE>
    <GRANULENUM>50.16</GRANULENUM>
    <HEADING>Section 50.16</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 40" SEQ="3">Protection of Environment</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="2">ENVIRONMENTAL PROTECTION AGENCY (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER C" SEQ="1">AIR PROGRAMS</PARENT>
      <PARENT HEADING="PART 50" SEQ="0">NATIONAL PRIMARY AND SECONDARY AMBIENT AIR QUALITY STANDARDS</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 50.16</SECTNO>
    <SUBJECT>National primary and secondary ambient air quality standards for lead.</SUBJECT>
    <P>(a) The national primary and secondary ambient air quality standards for lead (Pb) and its compounds are 0.15 micrograms per cubic meter, arithmetic mean concentration over a 3-month period, measured in the ambient air as Pb either by:</P>
    <P>(1) A reference method based on Appendix G of this part and designated in accordance with part 53 of this chapter or;</P>
    <P>(2) An equivalent method designated in accordance with part 53 of this chapter.</P>
    <P>(b) The national primary and secondary ambient air quality standards for Pb are met when the maximum arithmetic 3-month mean concentration for a 3-year period, as determined in accordance with Appendix R of this part, is less than or equal to 0.15 micrograms per cubic meter.</P>