<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>49</CFRTITLE>
    <CFRTITLETEXT>Transportation</CFRTITLETEXT>
    <VOL>3</VOL>
    <DATE>2011-10-01</DATE>
    <ORIGINALDATE>2011-10-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Continuing surveillance.</TITLE>
    <GRANULENUM>192.613</GRANULENUM>
    <HEADING>Section 192.613</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 49" SEQ="5">Transportation</PARENT>
      <PARENT HEADING="Subtitle B" SEQ="4">Other Regulations Relating to Transportation (Continued)</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER D" SEQ="2">PIPELINE SAFETY</PARENT>
      <PARENT HEADING="PART 192" SEQ="1">TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS</PARENT>
      <PARENT HEADING="Subpart L" SEQ="0">Operations</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 192.613</SECTNO>
    <SUBJECT>Continuing surveillance.</SUBJECT>
    <P>(a) Each operator shall have a procedure for continuing surveillance of its facilities to determine and take appropriate action concerning changes in class location, failures, leakage history, corrosion, substantial changes in cathodic protection requirements, and other unusual operating and maintenance conditions.</P>
    <P>(b) If a segment of pipeline is determined to be in unsatisfactory condition but no immediate hazard exists, the operator shall initiate a program to recondition or phase out the segment involved, or, if the segment cannot be reconditioned or phased out, reduce the maximum allowable operating pressure in accordance with § 192.619 (a) and (b).</P>
  </SECTION>