<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>49</CFRTITLE>
    <CFRTITLETEXT>Transportation</CFRTITLETEXT>
    <VOL>3</VOL>
    <DATE>2012-10-01</DATE>
    <ORIGINALDATE>2012-10-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Customer meter installations: Operating pressure.</TITLE>
    <GRANULENUM>192.359</GRANULENUM>
    <HEADING>Section 192.359</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 49" SEQ="5">Transportation</PARENT>
      <PARENT HEADING="Subtitle B" SEQ="4">Other Regulations Relating to Transportation (Continued)</PARENT>
      <PARENT HEADING="CHAPTER I" SEQ="3">PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED)</PARENT>
      <PARENT HEADING="SUBCHAPTER D" SEQ="2">PIPELINE SAFETY</PARENT>
      <PARENT HEADING="PART 192" SEQ="1">TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS</PARENT>
      <PARENT HEADING="Subpart H" SEQ="0">Customer Meters, Service Regulators, and Service Lines</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 192.359</SECTNO>
    <SUBJECT>Customer meter installations: Operating pressure.</SUBJECT>
    <P>(a) A meter may not be used at a pressure that is more than 67 percent of the manufacturer's shell test pressure.</P>
    <P>(b) Each newly installed meter manufactured after November 12, 1970, must have been tested to a minimum of 10 p.s.i. (69 kPa) gage.</P>
    <P>(c) A rebuilt or repaired tinned steel case meter may not be used at a pressure that is more than 50 percent of the pressure used to test the meter after rebuilding or repairing.</P>
    <CITA>[35 FR 13257, Aug. 19, 1970, as amended by Amdt. 192-1, 35 FR 17660, Nov. 17, 1970; Amdt. 192-85, 63 FR 37503, July 13, 1998]</CITA>
  </SECTION>