<?xml version="1.0"?>
<?xml-stylesheet type="text/xsl" href="cfr.xsl"?>
<CFRGRANULE xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:noNamespaceSchemaLocation="CFRMergedXML.xsd">
  <FDSYS>
    <CFRTITLE>10</CFRTITLE>
    <CFRTITLETEXT>Energy</CFRTITLETEXT>
    <VOL>3</VOL>
    <DATE>2013-01-01</DATE>
    <ORIGINALDATE>2013-01-01</ORIGINALDATE>
    <COVERONLY>false</COVERONLY>
    <TITLE>Metal halide lamp ballasts and fixtures.</TITLE>
    <GRANULENUM>429.54</GRANULENUM>
    <HEADING>Section 429.54</HEADING>
    <ANCESTORS>
      <PARENT HEADING="Title 10" SEQ="4">Energy</PARENT>
      <PARENT HEADING="CHAPTER II" SEQ="3">DEPARTMENT OF ENERGY</PARENT>
      <PARENT HEADING="SUBCHAPTER D" SEQ="2">ENERGY CONSERVATION</PARENT>
      <PARENT HEADING="PART 429" SEQ="1">CERTIFICATION, COMPLIANCE, AND ENFORCEMENT FOR CONSUMER PRODUCTS AND COMMERCIAL AND INDUSTRIAL EQUIPMENT</PARENT>
      <PARENT HEADING="Subpart B" SEQ="0">Certification</PARENT>
    </ANCESTORS>
  </FDSYS>
  <SECTION>
    <SECTNO>§ 429.54</SECTNO>
    <SUBJECT>Metal halide lamp ballasts and fixtures.</SUBJECT>
    <P>(a) <E T="03">Sampling plan for selection of units for testing.</E> (1) The requirements of § 429.11 are applicable to metal halide lamp ballasts; and</P>
    <P>(2) For each basic model of metal halide lamp ballast selected for testing, a sample of sufficient size, not less than four, shall be selected at random and tested to ensure that:</P>

    <P>(i) Any represented value of estimated energy efficiency calculated as the measured output power to the lamp divided by the measured input power to the ballast (P<E T="52">out</E>/P<E T="52">in</E>), of a basic model is less than or equal to the lower of:</P>
    <P>(A) The mean of the sample, where:</P>
    <GPH DEEP="55" SPAN="2">
      <GID>ER07MR11.130</GID>
    </GPH>
    <FP>Or,</FP>
    
    <P>(B) The lower 99-percent confidence limit (LCL) of the true mean divided by 0.99.</P>
    <GPH DEEP="22" SPAN="2">
      <GID>ER02AU11.090</GID>
    </GPH>
    <PRTPAGE P="189"/>
    <P>And <E T="0154">x</E> is the sample mean; s is the sample standard deviation; n is the number of samples; and t<E T="52">0.99</E> is the t statistic for a 99% two-tailed confidence interval with n-1 degrees of freedom (from appendix A).</P>
    <P>(b) <E T="03">Certification reports.</E> (1) The requirements of § 429.12 are applicable to metal halide lamp ballasts; and</P>

    <P>(2) Pursuant to § 429.12(b)(13), a certification report shall include the following public product-specific information: The minimum ballast efficiency in percent (%), the lamp wattage in watts (W), and the type of ballast (<E T="03">e.g.,</E> pulse-start, magnetic probe-start, and non-pulse start electronic).</P>
    <CITA>[76 FR 12451, Mar. 7, 2011; 76 FR 24780, May 2, 2011; 76 FR 46202, Aug. 2, 2011]</CITA>
  </SECTION>