SUMMARY: We propose to adopt a new airworthiness directive (AD) for 
certain Boeing Model 747-400 series airplanes. This proposed AD was 
prompted by reports of water leaking into electrical and electronic 
equipment in the main equipment center, which could result in an 
electrical short and potential loss of several functions essential for 
safe flight. This proposed AD would require modifying the floor panels, 
removing drains; installing floor supports, floor drain trough 
doublers, drain troughs, and drains; and sealing and taping the floor 
panels. We are proposing this AD to correct the unsafe condition on 
these products.

DATES: We must receive comments on this proposed AD by November 25, 
2011.

ADDRESSES: You may send comments, using the procedures found in 14 CFR 
11.43 and 11.45, by any of the following methods:
     Federal eRulemaking Portal: Go to http://www.regulations.gov. Follow the instructions for submitting comments.
     Fax: 202-493-2251.
     Mail: U.S. Department of Transportation, Docket 
Operations, M-30, West Building Ground Floor, Room W12-140, 1200 New 
Jersey Avenue, SE., Washington, DC 20590.
     Hand Delivery: Deliver to Mail address above between 9 
a.m. and 5 p.m., Monday through Friday, except Federal holidays.
    For service information identified in this proposed AD, contact 
Boeing Commercial Airplanes, Attention: Data & Services Management, P. 
O. Box 3707, MC 2H-65, Seattle, Washington 98124-2207; phone: 206-544-
5000, extension 1; fax: 206-766-5680; e-mail: [email protected]; 
Internet: https://www.myboeingfleet.com. You may review copies of the 
referenced service information at the FAA, Transport Airplane 
Directorate, 1601 Lind Avenue, SW., Renton, Washington. For information 
on the availability of this material at the FAA, call 425-227-1221.

Examining the AD Docket

    You may examine the AD docket on the Internet at http://www.regulations.gov; or in person at the Docket Management Facility 
between 9 a.m. and 5 p.m., Monday through Friday, except Federal 
holidays. The AD docket contains this proposed AD, the regulatory 
evaluation, any comments received, and other information. The street 
address for the Docket Office (phone: 800-647-5527) is in the ADDRESSES 
section. Comments will be available in the AD docket shortly after 
receipt.

FOR FURTHER INFORMATION CONTACT: Francis Smith, Aerospace Engineer, 
Cabin Safety & Environmental Systems Branch, ANM-150S, Seattle Aircraft 
Certification Office (ACO), FAA, 1601 Lind Avenue, SW., Renton, 
Washington 98057-3356; phone: 425-917-6596; fax: 425-917-6590; e-mail: 
[email protected].

SUPPLEMENTARY INFORMATION:

Comments Invited

    We invite you to send any written relevant data, views, or 
arguments about this proposal. Send your comments to an address listed 
under the ADDRESSES section. Include ``Docket No. FAA-2011-1065; 
Directorate Identifier 2011-NM-007-AD'' at the beginning of your 
comments. We specifically invite comments on the overall regulatory, 
economic, environmental, and energy aspects of this proposed AD. We 
will consider all comments received by the closing date and may amend 
this proposed AD because of those comments.
    We will post all comments we receive, without change, to http://www.regulations.gov, including any personal information you provide. We 
will also post a report summarizing each substantive verbal contact we 
receive about this proposed AD.

Discussion

    We have received reports of water leaking into electrical and 
electronic equipment in the main equipment center on Model 747-400 
Boeing Converted Freighter (BCF) airplanes. The water leaked through 
the main deck floor panels, fasteners, and floor fittings. The source 
of the water includes rain and snow coming in through the main deck 
doors, as well as wet cargo. This condition, if not corrected, could 
result in an electrical short and potential loss of several functions 
essential for safe flight.

Relevant Service Information

    We reviewed Boeing Special Attention Service Bulletin 747-25-3586, 
dated November 12, 2010. This service information describes procedures 
for the following actions at stations 210 and 530.
     Modifying by removing and reworking floor panels
     Removing drains
     Installing new floor supports
     Installing floor drain trough doublers, and drain troughs
     Installing new drains

Additionally, in certain areas between stations 140 and 640, this 
service information describes installing sealant and tape.

FAA's Determination

    We are proposing this AD because we evaluated all the relevant 
information and determined the unsafe condition described previously is 
likely to exist or develop in other products of the same type design.

[[Page 62668]]

Proposed AD Requirements

    This proposed AD would require accomplishing the actions specified 
in the service information described previously.

Costs of Compliance

    We estimate that this proposed AD affects 12 airplanes of U.S. 
registry.
    We estimate the following costs to comply with this proposed AD:

                                                                     Estimated Costs
--------------------------------------------------------------------------------------------------------------------------------------------------------
                Action                          Labor cost          Parts cost            Cost per product                 Cost on U.S.  operators
--------------------------------------------------------------------------------------------------------------------------------------------------------
Floor panel reworking and sealing;      Up to 644 work-hours x         $64,033  Up to $118,773.....................  Up to $1,425,276.
 installing drains, drain trough         $85 per hour = $54,740.
 doublers, and drain troughs.
--------------------------------------------------------------------------------------------------------------------------------------------------------

    According to the manufacturer, some of the costs of this proposed 
AD may be covered under warranty, thereby reducing the cost impact on 
affected individuals. We do not control warranty coverage for affected 
individuals. As a result, we have included all costs in our cost 
estimate.

Authority for This Rulemaking

    Title 49 of the United States Code specifies the FAA's authority to 
issue rules on aviation safety. Subtitle I, section 106, describes the 
authority of the FAA Administrator. Subtitle VII: Aviation Programs, 
describes in more detail the scope of the Agency's authority.
    We are issuing this rulemaking under the authority described in 
Subtitle VII, Part A, Subpart III, Section 44701: ``General 
requirements.'' Under that section, Congress charges the FAA with 
promoting safe flight of civil aircraft in air commerce by prescribing 
regulations for practices, methods, and procedures the Administrator 
finds necessary for safety in air commerce. This regulation is within 
the scope of that authority because it addresses an unsafe condition 
that is likely to exist or develop on products identified in this 
rulemaking action.

Regulatory Findings

    We determined that this proposed AD would not have federalism 
implications under Executive Order 13132. This proposed AD would not 
have a substantial direct effect on the States, on the relationship 
between the national Government and the States, or on the distribution 
of power and responsibilities among the various levels of government.
    For the reasons discussed above, I certify this proposed 
regulation:
    (1) Is not a ``significant regulatory action'' under Executive 
Order 12866,
    (2) Is not a ``significant rule'' under the DOT Regulatory Policies 
and Procedures (44 FR 11034, February 26, 1979),
    (3) Will not affect intrastate aviation in Alaska, and
    (4) Will not have a significant economic impact, positive or 
negative, on a substantial number of small entities under the criteria 
of the Regulatory Flexibility Act.

List of Subjects in 14 CFR Part 39

    Air transportation, Aircraft, Aviation safety, Incorporation by 
reference, Safety.

The Proposed Amendment

    Accordingly, under the authority delegated to me by the 
Administrator, the FAA proposes to amend 14 CFR part 39 as follows:

PART 39--AIRWORTHINESS DIRECTIVES

    1. The authority citation for part 39 continues to read as follows:

    Authority: 49 U.S.C. 106(g), 40113, 44701.


Sec.  39.13  [Amended]

    2. The FAA amends Sec.  39.13 by adding the following new 
airworthiness directive (AD):

The Boeing Company: Docket No. FAA-2011-1065;
    Directorate Identifier 2011-NM-007-AD.

(a) Comments Due Date

    We must receive comments by November 25, 2011.

(b) Affected ADs

    None.

(c) Applicability

    This AD applies to The Boeing Company Model 747-400 series 
airplanes, certificated in any category, as identified in Boeing 
Special Attention Service Bulletin 747-25-3586, dated November 12, 
2010.

(d) Subject

    Joint Aircraft System Component (JASC)/Air Transport Association 
(ATA) of America Code 25, Equipment and Furnishings.

(e) Unsafe Condition

    This AD was prompted by reports of water leaking into electrical 
and electronic equipment in the main equipment center. We are 
issuing this AD to prevent water from entering the main equipment 
center, which could result in an electrical short and potential loss 
of several functions essential for safe flight.

(f) Compliance

    Comply with this AD within the compliance times specified, 
unless already done.

(g) Floor Panel Sealing

    Within 24 months after the effective date of this AD: Modify the 
floor panels; remove drains; install floor supports, floor drain 
trough doublers, drain troughs, and drains; and seal and tape the 
floor panels; at the applicable locations; in accordance with the 
Accomplishment Instructions of Boeing Special Attention Service 
Bulletin 747-25-3586, dated November 12, 2010.

(h) Alternative Methods of Compliance (AMOCs)

    (1) The Manager, Seattle Aircraft Certification Office (ACO), 
FAA, has the authority to approve AMOCs for this AD, if requested 
using the procedures found in 14 CFR 39.19. In accordance with 14 
CFR 39.19, send your request to your principal inspector or local 
Flight Standards District Office, as appropriate. If sending 
information directly to the manager of the ACO, send it to the 
attention of the person identified in the Related Information 
section of this AD. Information may be e-mailed to: [email protected].
    (2) Before using any approved AMOC, notify your appropriate 
principal inspector, or lacking a principal inspector, the manager 
of the local flight standards district office/certificate holding 
district office.

(i) Related Information

    (1) For more information about this AD, contact Francis Smith, 
Aerospace Engineer, Cabin Safety & Environmental Systems Branch, 
ANM-150S, Seattle Aircraft Certification Office (ACO), FAA, 1601 
Lind Avenue SW., Renton, Washington 98057-3356; phone: 425-917-6596; 
fax: 425-917-6590; e-mail: [email protected].
    (2) For service information identified in this AD, contact 
Boeing Commercial Airplanes, Attention: Data & Services Management, 
P. O. Box 3707, MC 2H-65, Seattle, Washington 98124-2207; phone: 
206-544-5000, extension 1; fax: 206-766-

[[Page 62669]]

5680; e-mail: [email protected]; Internet: https://www.myboeingfleet.com.You may review copies of the referenced 
service information at the FAA, Transport Airplane Directorate, 1601 
Lind Avenue, SW., Renton, Washington. For information on the 
availability of this material at the FAA, call 425-227-1221.

    Issued in Renton, Washington, on September 30, 2011.
Ali Bahrami,
Manager, Transport Airplane Directorate, Aircraft Certification 
Service.
[FR Doc. 2011-26105 Filed 10-7-11; 8:45 am]